1、 INCH-POUND MIL-DTL-7793/1C 19 October 2012 SUPERSEDING MIL-DTL-7793/1B 18 March 2005 DETAIL SPECIFICATION SHEET METER, TIME TOTALIZING, MINIATURE, DIGITAL, 28 VDC, SQUARE This specification is approved for use by all Departments and Agencies of the Department of Defense. Reactivated after 19 Octobe
2、r 2012 and may be used for new and existing designs and acquisitions. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-7793. REQUIREMENTS: 1. Configuration. The meter shall meet the requirements on figure 1 and table I. 2. Tolerances.
3、Unless otherwise specified in MIL-DTL-7793 or this specification sheet, tolerances are 0.02 inch for two-place decimals and 0.015 inch for three-place decimals. 3. Mounting flange. Meters with fixed flanges shall be tin plated on the front surface of the mounting flange in accordance with Class C of
4、 ASTM-B545, “Tin, Electrodeposited Coatings of,” or ASTM-B339, “Pig Tin,” to provide an electrical ground for the case (see Note 2 of this specification sheet). 4. Life accuracy. Meter accuracy shall be 0.1 percent from -85 to 257 F (-65 to 125 C) and across the maximum and minimum input operating v
5、oltage range specified in table I. 5. Power consumption. The average power consumption at 28 volts direct current (V DC) shall not be greater than 85 milliwatts. 6. Ripple voltage. The meter shall continue to operate as specified in MIL-DTL-7793 when subjected to a cyclic peak of ripple voltage (see
6、 Note 3) of less than 2.0 VDC and the frequency-voltage coordinates on figure 2. AMSC N/A FSC 6645 Provided by IHSNot for Resale-,-,-MIL-DTL-7793/1C 2 6.1 Ripple voltage measurement. The ripple voltage shall be measured with a peak reading voltmeter in series with a 4.0-microfarad capacitor. The hig
7、her of the two values measured when the voltmeter is successively connected to each of two polarities shall be considered the ripple voltage. 6.2 Frequency characteristics. The frequency components of the ripple voltage shall be within the limits on figure 2 when measured as conducted interference.
8、7. Operating temperature range. The operating temperature range shall be from -85 to 257 F (-65 to 125 C). 8. Time range. Total readout of the meters shall be 9999 hours. 9. Line drop. Line drop (see Note 4) shall be less than 2 VDC. 10. Transient protection. No temporary or permanent degradation sh
9、all be produced in the meter for the input voltage and time values shown on figure 3 and figure 4 (80V and 600V transient, respectively). 10.1 Transient voltage. Transient surge voltages shall be within the limits on figure 3 when converted to their equivalent step functions. Transient spike voltage
10、s shall be within the limits shown on figure 4. They shall be not greater than 600V nor depart from the normal wave form for more than 50 microseconds. 11. Dielectric strength test voltages. The dielectric test voltages shall be 350 V root mean square (rms) at altitude specified in MIL-DTL-7793 and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL77931C2012METERTIMETOTALIZINGMINIATUREDIGITAL28VDCSQUAREPDF

链接地址:http://www.mydoc123.com/p-978864.html