NAVY MIL-DTL-24643 42 D-2009 CABLE ELECTRICAL -20 degree C TO +90 degree C TYPE LS1SU《LS1SU型-20 ℃~+90℃电缆》.pdf
《NAVY MIL-DTL-24643 42 D-2009 CABLE ELECTRICAL -20 degree C TO +90 degree C TYPE LS1SU《LS1SU型-20 ℃~+90℃电缆》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-24643 42 D-2009 CABLE ELECTRICAL -20 degree C TO +90 degree C TYPE LS1SU《LS1SU型-20 ℃~+90℃电缆》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-DTL-24643/42D 1 October 2009 SUPERSEDING MIL-DTL-24643/42C 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS1SU This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the p
2、roduct described herein shall consist of this specification sheet and MIL-DTL-24643. Construction, Non-Watertight First - Copper conductor, tin-coated, ASTM B286, 20 AWG 7 strands and 18 AWG, Class B stranding, ASTM B8 (7 by 0.0152 inches). For LS1SU-36, 32 AWG, Size 20 conductors and 4 AWG, Size 18
3、 conductors. For LS1SU-60, 60 AWG, Size 20 conductors. Second - Separator may be used at manufacturers option where required to provide free-stripping insulation. Third - Thermoset insulation. Nominal wall thickness of 0.017 inch. Wall thickness may vary from nominal as necessary in order for comple
4、ted cable to meet the specified electrical requirements. Fourth - Braided shield of 34 or 36 AWG, coated or uncoated copper. Braid angle of 30 to 35 degrees; minimum coverage of 85 percent. Fifth - Shield insulation of two polyester tapes, outer tape sealed. An alternate shield insulation may consis
5、t of one polyester tape, plus an extruded jacket of a suitable transparent material, minimum average thickness of the transparent material 0.003 inch. The standard identification code shall be applied by Method 2. For LS1SU-36, the four 18 AWG conductors shall be numbered 1 through 4. Sixth - The sp
6、ecified number of singles (see table I) shall be cabled together in accordance with 3.4.4 of MIL-DTL-24643. Cabling sequence shall be consecutive starting with no. 1 from the center outward. Fillers may be used as necessary to form a firm well-rounded assembly. Seventh - An optional binder. Eighth -
7、 Cross-linked polyolefin jacket (see table I for thickness). AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/42D TABLE I. Details. Overall diameter Military part no. M24643/42 Type and size Number of conductors Conduct
8、or size AWG no. Cable jacket thickness min. avg. (inch) min. (inch) max. (inch) -01UN LS1SU-36 4 32 18-7 20-7 0.075 0.910 0.985 -02UN LS1SU-60 60 20-7 0.100 1.210 1.310 REQUIREMENTS: Qualification required. INSPECTION: Basic Electricals: Conductor resistance (ohms/1000 feet at 25 C, max.) ASTM B286,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL2464342D2009CABLEELECTRICAL20DEGREECTO90DEGREECTYPELS1SULS1SU 20 90 电缆 PDF

链接地址:http://www.mydoc123.com/p-978669.html