NAVY MIL-DTL-24643 32 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS2SWAU《LS2SWAU型 -20 ℃~+90 ℃电缆》.pdf
《NAVY MIL-DTL-24643 32 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS2SWAU《LS2SWAU型 -20 ℃~+90 ℃电缆》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-24643 32 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS2SWAU《LS2SWAU型 -20 ℃~+90 ℃电缆》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-DTL-24643/32F 1 October 2009 SUPERSEDING MIL-DTL-24643/32E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS2SWAU This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the
2、 product described herein shall consist of this specification sheet and MIL-DTL-24643. Construction, Watertight First - Copper conductor, coated or uncoated, ASTM B286, 22 AWG 7 strands. Second - Separator may be used at manufacturers option where required to provide free-stripping insulation. Third
3、 - Thermoset insulation. Nominal wall thickness of 0.013 inch; wall thickness may vary from nominal as necessary, in order for the completed cable to meet the specified electrical requirements. Colored insulation, one white and one black conductor for each pair. Fourth - Two conductors (one black an
4、d one white) cabled together with a nominal lay of 2.5 inches to form a pair. Fifth - An optional binder. Sixth - Braided shield of 34 or 36 AWG, tin-coated copper. Braid angle of 30 to 35 degrees; minimum coverage of 85 percent. Seventh - Shield insulation of two polyester tapes, outer tape sealed.
5、 An alternate shield insulation may consist of one polyester tape, plus an extruded jacket of a suitable transparent material, minimum average thickness of the transparent material 0.003 inch. The standard identification code shall be applied by Method 2. Eighth - The specified number of pairs (see
6、table I) shall be cabled together in accordance with 3.4.4 of MIL-DTL-24643. Cabling sequence shall be consecutive starting with no. 1 from the center outward. Fillers may be used as necessary to form a firm well-rounded assembly. Ninth - An optional binder. Tenth - Cross-linked polyolefin jacket (s
7、ee table I for thickness). AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/32F TABLE I. Details. Overall diameter Military part no. M24643/32 Type and size Number of pairs Cable jacket thickness min avg. (inch) min. (i
8、nch) max. (inch) -01UN LS2SWAU-3 3 0.050 0.480 0.520 -02UN LS2SWAU-7 7 0.050 0.610 0.660 -03UN LS2SWAU-10 10 0.050 0.770 0.830 -04UN LS2SWAU-14 14 0.063 0.860 0.930 -05UN LS2SWAU-19 19 0.063 0.970 1.040 -06UN LS2SWAU-24 24 0.063 1.120 1.210 -07UN LS2SWAU-30 30 0.063 1.190 1.280 -08UN LS2SWAU-37 37 0
9、.063 1.290 1.380 -09UN LS2SWAU-44 44 0.063 1.460 1.550 -10UN LS2SWAU-61 61 0.075 1.660 1.740 REQUIREMENTS: Qualification required. INSPECTION: Basic Electricals: Conductor resistance (ohms/1000 feet at 25 C, max.) 17.37 Voltage withstand (volts, root mean square, min.) Conductor to conductor 2000 Co
10、nductor to shield 1000 Component shield to component shield 500 Insulation resistance (megohms/1000 feet, min.) Conductor to conductor 500 Conductor to shield 500 Component shield to component shield 100 Conductor continuity No failure Shield continuity No failure Group A: Visual and dimensional No
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL2464332F2009CABLEELECTRICAL20DEGREECTO90DEGREECTYPELS2SWAULS2SWAU 20 90 电缆 PDF

链接地址:http://www.mydoc123.com/p-978658.html