《NAVY MIL-D-28736 B-1971 DECODER GROUP AN UPA-59(V) IFF MK XII (SIF) WITH ACTIVE READOUT AND ASSOCIATED MODIFICATION TO INDICATORS (PPI)《AN UPA-59(V) IFF MK XII(SIF)型译码机 有着敏捷的读出器和相关.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-D-28736 B-1971 DECODER GROUP AN UPA-59(V) IFF MK XII (SIF) WITH ACTIVE READOUT AND ASSOCIATED MODIFICATION TO INDICATORS (PPI)《AN UPA-59(V) IFF MK XII(SIF)型译码机 有着敏捷的读出器和相关.pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-D-287 36B (EC) 20- December 1971 SUPERSEDING . . MIL-D-28736A(EC) 15 September 1970 (see 6.6) MILITARY SPECIFICATION DCODER GROUP, AN/UPA-59 (V) IFF MK XII (SIF) , WITH ACTIVE BELux)LpT AND ASS0CLATE. IDIFIGATION 20 INDICATORS (?PI) 1. SCOPE - . 1. . 1.1 This specification covers the constructio
2、n and inspection of complete ad operative lightweight decoder groups. Also covered under this specification are active readouts appropriate or the particular decoder group types and - auxiliary functions such as automatic ,emergency alarm and selected altitude layer operation. 1.2 “he decoder group
3、shall accept IFF MK XII (SIF) video signals from the interrogator and decode the signals either passively or actively or both simul- taneously. Passive decoding shall include both bracket and SIF codes. Active readout shall be accomplished on an SIF signal (including altitude signal) ap- pearing wit
4、hin a range/azimuth gate on an associated indicator (PPI), and the -ctfve readout portion of the equipment shall display the SIF code numbers of The equipment shall be in accordance with the provisions of MIL-E-16400, except as hereinafter specified. 3.2.1 Description. The decoder group shall be pro
5、vided with maintenance aids and publication materials as set forth herein and shall consist of the following primary functions aa detailed herein: (a) Decoder (b) Set control (c) mergency alarm (d) Selected altitude layer (e ) Active readout capab i li ty The decoder group shall consist of the follo
6、wing separate items: (1) Basic decoder, AN/UPA-59(V) (See 3.6 except 3.6.6,1.5(a) (2) Emergency alarm speaker, BZ-173/UPA-59(V) (see 3.6.4) (3) Active readout unit, ID-1447 (see 3.6.6 except 3.6.6.1.10) (4) PPI modification kit, MK-l336/SPA (see 3.6.6.1.10) When active readout. units are not require
7、d operationally, the basic decoder shall be identical to that described in this specification and for operation with the active readout unit to avoid modifications other than the simple addition of the active readout unit (and appropriate PPI indicator modifications) should active type of operation
8、be desired at a later time. basic decoder, the active readout unit and their interconnection, shall be patterned to permit both integral and remote operation of the active readout unit. To accomplish this flexibility, a parallel wired rear panel connector shall be supplied in the basic decoder for u
9、se with the active readout remote cable required herein (see 3.6.6.1.8). Source impedances for driving the active readout unit shall be designed to allow both integral and remote active read- out operation simultaneously,or individually. No circuitry or function shall be included in the equipment wh
10、ich will preclude the easy field addition of expansion to ten specially gelected codes simultaneously. To facilitate such expansion the output connector for the active readout shall provide at least The design of the . the following: (a) bracket video, (b) mode tags or gates, (c) reply trains in par
11、allel form, that is, after and (e) challenged mode lines lines to the passive decoder, decoding, (d) tagged video reset signal decode., up to five modes which parallel the interrogator and (f) degarble output. 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
12、m IHS-,-,-MIL-D-28736B(EC) 3.2.1.1 The decoder group shall be fully compatible when operated in connection with interrogators and radar -sets such as the AN/UPX-l, II and UPX-23. 24A, 24B, 24C and AN/UPA-50. In addition to providing the SIF decoding function, the equipment shall provide certain othe
13、r decoding features as required herein. In addition to the conventional. acceptance of individualized inpucs of %Zes 1, 2, 3/A, 4, and C, the decoder groups shall, by simple irstaliation cYimgEs, be capable of accepting these modes in the form of tagged video. Mo organizational maintenance, field ma
14、intenance, and depot maintenance. Organizational maintenance is defined as that maintenance performed on equip- ment while installed and which is performed during periodic inspections. Organi- zational maintenance is limited to functional or operational checks to determine quality of performance and
15、 operational readiness ; and periodic checks and repairs required to ensure to the maximum possible extent that the equipment will operate throughout the next periodic level. Field maintenance is defined as that main- tenance required to isolate and repair faulty modules and subassemblies, adjust- m
16、ent and alignment of parts, and equipments. Depot maintenance is that mainte- nance required to completely disassemble, allow detail analysis, and repairs of equipment subassemblies and parts. 3.2.3.2 Equipment part layout. Test points shall be chosen to provide a Maintenance considerations shall pr
17、ovide straightforward, logical step-by-step troubleshooting sequence as well as a single end-to-end performance check. for the identification of where and how to break loop or feedback circuits.to allow for proper signal injection with test equipment and a step-by-step 5 Provided by IHSNot for Resal
18、eNo reproduction or networking permitted without license from IHS-,-,-MIL-D-2873bB 58 m 7779706 035LI472 T MILiD-28736B (EC) troubleshooting, adjustment or alignment of the circuit. Test points shall be located so that all are accessible without moving or rotating the equipment on the bench. equipme
19、nt installed, or completely assembled on the bench should be located on the front panel. between test points and other parts, to eliminate the possibility of arcing, faulty readings of signals, or damage to equipment or parts. Test points shall be provided for essential waveforms and voltage measure
20、ments where terminals are not otherwise accessible. The test points shall be identified with a des- ignation, for example, “TP-10“. Provisions shall be made to accept all test probes with handles up to one inch in diameter and with a probe size of 0.08 inch 50.002 inch, when equipment is in operable
21、 conditions. Those test points which provide end-to-end performance test on Adequate spacing shall be provided between test points, and 3.2.3.2.1 The above requirement shall provide essential test points. How- wer, signal inputs and outputs are an absolute mnimum on all plug-in sub- assemblies. Test
22、 points for all direct current (dc) supply voltages shall be provided and shall be plainly labeled and conveniently located for ease of servicing. 3.2.3.3 Maintenance consideration. Maintenance consideration shall pro- vide for the location of test points and the identification of procedures that -w
23、ill permit positive verification of equipment performance when installed. These considerations shall also provide for location of possible addition test points and for the identification of procedures that will permit positive verification and troubleshooting sequencel of functions within the equipm
24、ent, both singly and collectively, including end-to-end performance check of the assembled equipment. These maintenance considerations and procedures shall provide for a quality of repair, that will restore the equipment to an overall quality equal to or better than that required by the quality cont
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILD28736B1971DECODERGROUPANUPA59VIFFMKXIISIFWITHACTIVEREADOUTANDASSOCIATEDMODIFICATIONTOINDICATORSPPIANUPA59VIFFMKXIISIF

链接地址:http://www.mydoc123.com/p-978321.html