1、MIL-D-l7847E(SH) 29 September 1987 SUPERSEDING MIL-D-l7847D(SHIPS) 27 June 1966 (See 6.8) MILITARY SPECIFICATION DEHYDRATOR, DESICCANT, SEMI-AUTOMATIC, HIGH PRESSURE AIR This specification is approved for use within the Naval Sea Systems Command, Department of the Navy, and is available for use by a
2、ll Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers adsorptive purification and dehydra- tion equipment for removing solid contaminants and particulate and vaporous water and oil from shipboard high pressure air systems. used to denote the entire c
3、omplex of equipment throughout this specification. The word dehydrator will be 1.2 Classif ication. 1.2.1 Classes. Dehydrators shall be of the following classes, as specified (see 6.2). Class I Class II - 5000 lb/in2 gauge working pressure. - 3000 pounds per square inch (lb/in2) gauge working pres s
4、 Ure . 1.2.2 Ca acit . fied (see 6.d%dn practical, a unit with one of the following standard flow ratings should be selected. The required capacity of the dehydrator shall be as speci- (a) (b) (c) F-75 F-100 - 100 ft3/min minimum capacity. F-150 - 150 ft3/mn minimum capacity. - 75 standard cubic fee
5、t per minute (ft3/min) minimum capa city. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Naval Sea Systems Command, SEA 5523, Department of the Navy, Washington, DC 20362-5101 by usi
6、ng the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC N/A FSC 4460 DISTRIBUTION STATEMENT A Approved for public release; distribution unlimited I Provided by IHSNot for ResaleNo reproduction or networking permitted
7、 without license from IHS-,-,-MIL-D-178Y3E qrl m 999990b 0232ll33 5 MIIA-D-17847E(SH) 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications and standards. The following specifications and a dards form a part of this specification to the extent specified herein. Unless otherwise spec
8、ified, the issues of these documents shall be those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDICS) and supplement thereto, cited in the solicitation. SPECIFICATIONS FEDERAL QQ-N-288 QQ-S-7 63 MILITARY MIL-R- 19 6 MIL-S-901 MIL-E-91 7 MIL-S-2 94 0 MIL-
9、V-2961 MIL O -id al Q) O Lc P c 4 Fc s ib ido 9) Q) N Li P o m Li namely, working pressure, capacity, electrical data (for example voltage) dew point and oil content of influent and effluent air, and any other pertinent information. 13 Provided by IHSNot for ResaleNo reproduction or networking permi
10、tted without license from IHS-,-,-3.7.2 Identification plates. Identification plates in accordance with iri-?-l5024 and MIL-P-15024/5 shall be installed on the equipment. They shall be rely attached to a part of the equipment which will not be ordinarily renewed diiring normal service life. They sha
11、ll be located in a readily accessible posi- tion where they can be read at all times without danger to personnel. 3.7.3 Piping connections. Inlet and outlet air connections shall be designated. 3.7.4 Electrical and mechanical controls. Electrical and mechanical controls shall be suitably marked. 3.7
12、.5 instruction plate. An operating and safety instruction plate in accordance with MIL-P-15024 and MIL-P-15024/5 shall be provided to give the operator a clear, consise, step-by-step procedure for energizing the dehydrator and for shifting from one desiccant tower to another. It shall include operat
13、ion of the timer control and the control valves in conjunction with the various indi- cator lights. with the components identified therein. Any safety precautions required for safe operation and maintenance shall also be included. The instruction plate shall also include a schematic flow diagram 3.8
14、 Drawings. When the Government has limited rights in the data shown on these drawings as determined by the contractural provisions regarding rights in technical data, the drawings furnished herewith should be marked with the following restrictive legend: “Furnished under United States Government Con
15、tract No. . Shall not be either released outside the Government, or dupli- cated, or disclosed in whole or in part for manufacture or procurement, without the written permission of , except for: (a) emergency repair or overhaul work by or for the Government, where the item or process concerned is no
16、t otherwise reasonably available to enable timely performance of the work; or (b) release to a foreign government, as the interests of the United States may require; provided that in either case the release, use, duplication or disclosure hereof shall be subject to the foregoing limitations. This le
17、gend shall be marked on any reproduction hereof in whole or in part.“ Drawings which are sufficient to permit evaluation of 3.8.1 Bid drawings. the design and approval of materials shall be submitted as specified (see 6.3). The drawings shall show the following: I (a) Accurately scaled cross-section
18、al assembly and subassemblies which clearly depict the design and construction of the equipment . other data adequate to identify materials proposed. connections and location of mounts. Estimated dry weight and limitations on installation. Location of center of gravity. (b) Bill of material listing
19、specifications, grade, condition or (c) Outlined dimensions, disassembly space, location and size of end (d) (e) (f) Wiring diagrams and schematics. (g) Flow diagram. 14 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.8.2 Ship equipment drawing. Sh
20、ip equipment drawings shall be in accor- dance with DOWSTD-100 and DOD-D-1000. 3.8.2.1 Freliminary drawings. Preliminary drawings shall be submitted to The drawings the command or agency for approval prior to starting fabrication. shall include the information required by 3.8.1, and the following: (
21、a) Assembly and details of all piping components. “Form, fit, and function“ data shall be specified on the drawings. drawings shall show dimensions, finishes, concentricity, parallelism and squareness requireinents, material condition requirepwnts and all other information applicable to the manufact
22、ure and inspection of the part detailed. Detail (b) (c) Fabrication drawings depicting all pressure vessel, piping Assembly drawings of all other components. component, and piping welds. Welding and inspection proce- dures shall be specified on the drawings. Fabrication drawings listing welding and
23、inspection procedures for any other welded assembly which requires procedure approval as specified in MIL-STD-278. joints. Brazing and inspection procedures shall be specified on the drawings, and qualification test results submitted when required by NAVSHIPS 0900-LP-001-7000. (d) (e) Fabrication dr
24、awings depicting all pressure containing brazed 3.8.2.2 Final drawings. Final drawings shall include all changes required The by the drawings approved by the command or agency concerned and the information indicating validation by the command or agency concerned granting approval. drawings shall dep
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILD17847E1987DEHYDRATORDESICCANTSEMIAUTOMATICHIGHPRESSUREAIR 半自动 高压 空气 脱水器 干燥剂 PDF

链接地址:http://www.mydoc123.com/p-978261.html