1、MIL-C-82890 9999906 1859088 979 I INCH-POUND I MI L-C-82890(NAVY) 9 August 1993 MILITARY SPECIFICATION CARTRIDGE, FIRE EXTINGUISHER CCU-l20/A is specification is approved for use within the Naval Air Systems Command, Department of the Navy and is available for use by all Departments and Agencies of
2、the Department of Defense, 1. SCOPE 1.1 Scope. This specification covers the requirements for the CCU-l20/A Fire Extinguisher Cartridge, and is referred to herein as the “cartridge“. 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications and standards. The following specifications an
3、d standards form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation (see 6.2). 0
4、SPECIFICATIONS FEDERAL PPP-B-60 1 Boxes, Wood, Cleated-Plywood PPP-B-62 1 Boxes, Wood, Nailed and Lock-Corner MILITARY MIL-B- 13 1 Barrier Materials, Watervaporproof, Greaseproof, F1 ex ibl e, Heat -S ealabl e Beneficial comments (recommendations, additions, deletions) and any pertinent data which m
5、ay be of use in improving this document should be addressed to: Commander, Indian Head Division, Naval Surface Warfare Center, Standardization Branch (Code 8420), 101 Strauss Avenue, Indian Head, MD 20640-5035 by using the Standardization Document Improvement Proposai (DD Form 1426) appearing at the
6、 end of this document or sending a letter. AMSC NIA O FSC 1377 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Licensed by Information Handling ServicesMIL-A-2550 MIL-C-10464 MIL-1-23659 STANDARDS MILC-82890 Ammunition, General Specification for Cans, Hermetic Seali
7、ng, Metal, Light Gage, Tear-Strip Type Initiators, Electrical, General Design Specification for MILITARY MIL-STD-105 Sampling Procedures and Tables for Inspection by Attributes MIL-STD-109 Quality Assurance Terms and Definitions MIL-STD-129 Marking for Shipment and Storage MIL-STD-202 Test Methods f
8、or Electronic and Electrical Component Parts MIL-STD-453 Inspection, Radiographic MIL-STD-8 10 Environmental Test Methods and Engineering Guidelines MIL-STD- 1 168 Ammunition Lot Numbering (Unless otherwise indicated, copies of federal and military specifications and standards are available from the
9、 Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 191 11-5094.) 2.1.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unles
10、s otherwise specified, the issues shall be those cited in the solicitation. DOCUMENTS INDIAN HEAD DIVISION, NAVAL SURFACE WARFARE CENTER (IHD/NSWC) (CAGE Code 14083) 504- 174-TD-022 Detonator, Electric, BBU-43/A DRAWINGS NAVAL AIR SYSTEMS COMMAND (CAGE Code 30003) DL 1660AS 1 00 Detonator, Electric,
11、 BBU-43/A DL 1660AS408 CCU-I 20/A Cartridge, Fire Extinguisher 2 Licensed by Information Handling ServicesMIL-C-82890 9999906 I1859090 527 MILC-82890 (Application for copies should be addressed to the Commander, Indian Head Division, Naval Surface Warfare Center, Data Review and Control Branch, (Cod
12、e 8410P), 101 Strauss Avenue, Indian Head, MD 20640-5035.) PUBLICATIONS CODE OF FEDERAL REGULATIONS (CFR) 49 CFR 100-199 Transportation (Application for copies should be addressed to the Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402.) 2.2 Order of precedence. In
13、the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When
14、specified in the contract or purchase order (see 6.2), a first article sample shall be subjected to first article inspection (see 6.4) in accordance with 4.4. 3.2 Conformance to doci;ments. The CCU-l20/A Fire Extinguisher Cartridge covered by this specification shall be manufactured in accordance wi
15、th DL1660AS408 and ail documents listed thereon. The electric detonators shall be manufactured to conform to DL1660AS100 and Indian Head Division, Naval Surface Warfare Center (IHD/NSWC) 504-174-TD-022. 0 3.3 Materiais. All materials used in the manufacture of the cartridges shall conform strictly t
16、o the specifications referred to on the respective drawings unless specific approval in writing covering a departure therefrom has been obtained from the cognizant Navy design activity prior to manufacture. When alternate materiais or methods of manufacture are specified on the drawings, the bidders
17、 selections shall be clearly stated in the proposai. 3.4 Bridge circuit resistance. The bridge circuit resistance of the cartridge, when measured in accordance with 4.6.2 shall be 0.42 to 0.75 ohms. 3.5 Environmental. The cartridge shall meet the environmental resistance requirements of 3.5.1 throug
18、h 3.5.4. 3.5.1 Leakage. Each cartridge shall not exhibit a leak rate greater than 0.00001 (1 X cubic centimeters per second (cc/s) when tested in accordance with 4.6.3. 3.5.2 Vibration. The cartridge shall not autoignite, shall be safe to handle, show no evidence of disintegration of the propellant
19、or derangement of components, and shall meet the requirements of 3.4, 3.6, 3.7, and 3.8, at 70F following vibration testing of 4.6.4. 3 Licensed by Information Handling ServicesMIL-C-2890 = 777770b 3859073 4b3 MILC-82890 3.5.3 Six-foot drop. The cartridge shall meet the functional requirements of 3.
20、7 after the six- foot drop test (see 4.6.5). 3.5.4 Temperatureshock, humidity and altitude. The cartridge shall meet the requirements of 3.4 and 3.7 after being exposed to the temperature-shock, humidity and altitude environments specified in 4.6.6. 3.6 Radiographic examination. Radiographic inspect
21、ion shall verify proper assembly, thread form, presence of parts, positioning of detonators, proper crimping and sealing and proper electrical connections. Film interpretation of the radiographs shall verify the presence and correct positioning of all parts and explosives (see 4.6.7). 3.7 Functional
22、. The cartridge, when tested in accordance with 4.6.8, shall provide sufficient power to rupture the retaining disk of the container, permitting discharge of the fire extinguishing agent. There shall be no mechanical failure (see 6.5.1) or distortion that would impair removal of the cartridge. 3.7.1
23、 Misfires. There shall be no misfires. 3.8 Workmanship. Workmanship shall be in accordance with the requirements specified on the applicable drawings, reference specifications, and 3.8.1 through 3.8.3. 3.8.1 Metal defects. The metal parts shall be free from cracks, splits, cold shunts, inclusions, p
24、orosity or any other metal defects. 3.8.2 Burr. The cartridge shall not have a burr which might interfere with the assembly or function of the item or which might be injurious to personnel handling the item. 3.8.3 Foreign matter. The part or assembly shall not contain chips, dirt, grease, oil, rust,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILC828901993CARTRIDGEFIREEXTINGUISHERCCU120ACCU120A 型瓶式 灭火器 PDF

链接地址:http://www.mydoc123.com/p-978119.html