NAVY MIL-C-19787 C-1969 CABLE ELECTRIC TORPEDO 65 CONDUCTOR (FOR TORPEDO CONTROL ) SHOW 172《172显65导线鱼雷电索缆(用于鱼雷控制)》.pdf
《NAVY MIL-C-19787 C-1969 CABLE ELECTRIC TORPEDO 65 CONDUCTOR (FOR TORPEDO CONTROL ) SHOW 172《172显65导线鱼雷电索缆(用于鱼雷控制)》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-C-19787 C-1969 CABLE ELECTRIC TORPEDO 65 CONDUCTOR (FOR TORPEDO CONTROL ) SHOW 172《172显65导线鱼雷电索缆(用于鱼雷控制)》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-c- 19787 (os) mEc-19787NWeP) 29 July 1969 Supers edi ng 14 March i960 MILITARY SPECFICATION CA=, ELECTRIC, TORVEDO, 65 CONDUCTOR (FOR TRPEDO CONTXOL, EIECTRIC SETPING) This specification has been approved by the Naval Ordnance Systems Comnd, Department of the Navy 1. SCOPE 1.1 This specification
2、 covers the requirements for the procurement, manufacture, inspection, and testing of 65-conductor electric cables. The cables are distinguished by their miniature size, type of insulation, features of construction, and the general conditions of their service use. 1.2 Classification. The cables shal
3、l be of the following types, as specified (see 6.1): (a) Type MSW 65-onductor, Plain, Extra Thin Wall (b) Typ bSTcP 65-onductor, Plain, Thin Wail 2. AFFLICABIX DOCUMENTS 2.1 The following documents of issue in effect on the date of invita- tion for bids or request for proposals form a part of this s
4、pecification to the extent specified herein. SPECIFICATIONS FEDERAL QQ-W- 00343 Wire, Electrical, Uninsulated Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-C-L7787C bL W 77777Ob 0087823 O i MILITARY MIG C- 572 MIL- r 15 016 MIL- C-l2000 Cords,
5、 Yarns and Monofilements-Organic Synthetic Fiber fiubricating Oil, General Fwtpse Cable, Cord, and Wire, Electric; Packaging of SpArnRDS FEDERAL Fed Test Method Std Cable and Wire, insulated; Methods of 80. 228 Testing MCLSTD- i05 Sampling Procedures and Tables for Inspection by Attributes MILSTD- T
6、est Reports, Preparation of (Copies of specifications and standards required by contractors in connection with specific procurement functions should be obtained from th procuring activity or as directed by the contracting officer. ) Electric cables covered by this specification am minimum diameter c
7、ables having a tough abrasion-resisting polychloroprene sheath. The cables are designed to be compat.ible with special type electrical connectors and therefore must be of unifom cross-sectional area and compactness throughout the manufactured length. 3.1.1 MSTCP-65,25 psi minimum. 3.8.11 Minimum sta
8、ndards . The requirementc specified herein for each component material and for the completed cable assembly constitute the minimum acceptable standards for quality and performance under tests. 3.8.12 WorkmanshiE. The finished cable, including all components, shall be first class in workmanship and s
9、hall be constructed and finished in a manner to assure compliance with a11 requirements of this specifi- cation. area and compactness throughout the manufactured length. The standards of workmanship exhibited in any approved preproduction sample, subject to any qualification stated in the Government
10、s notice of approval, shall be determinative of the requirements of the contract relative to workman- ship insofar as not specifically covered by applicable specifications. Particular attention shall be paid to unifomnity of cross-sectional 4 . QUALITY ASSURANCE PROVISIONS 4 .i Responsibility for in
11、spection. Unless otherwise specif ied in the contract or purchase order, the supplier is responsible for the perfom- ance of all inspection requirements as specified herein. otherwise specified in the contract or order, the supplier may use his Except as 8 Provided by IHSNot for ResaleNo reproductio
12、n or networking permitted without license from IHS-,-,-MI-C-19787( OS) own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the
13、specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. 4.2 Sampling 4.2,1 - Lot. A lot shall be defined as follows, based upon footage ordered : Order - Up to 10,000 feet O,OO to SO,OOO feet Over 50,000 feet Lot Size Total Order
14、10,000 feet 25,000 feet 4.2.1.1 Unit of inspection. The unit of inspection for the determina- tion of sample size shall be one inspection length. (An inspection length is defined as one manufactured, completed cable of one type offered to the inspector for acceptance. ) 4.2.2 Number of samples 4.2.2
15、.1 First article sample. When required (see 3.2), one first article sample of 100 feet of each type of cable being procured shall be supplied by the contractor. Samples accepted will be applied as part of the quantity specified in the contract or order. submitted for first article testing at an acti
16、vity designated in the con- tract or order or by the Naval Ordnance Systems Command. duction of cable prior to report of satisfactory compliance to specified requirements or approval by the contracting activity shall be at the con- tractors risk. The sample shall be Further pro- 4.2.2.2 Quality conf
17、ormance sample. 4.3 Inspection The saapling plan and tests to be performed shall be as designated in the applicable test paragraph. 4 . 3 . 1 Classification of inspection . The examination and testing of cables covered by this specification shall be classified as follows: 4.3.1.1 First article. Firs
18、t article inspection to determine com- pliance with minimum requirements shall be in accordance with 4.4.2 through 4.4.11. 4 . 3.1.2 Quality conformance . Quality conf ormce inspection to deter- mine acceptability of the lot as defined in 4.2.1 shall consist of the tests or inspections of 4.4.2 thro
19、ugh 4.4.11. 9 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-I_ fl1 L- C - 19 7 B 7 C b l-T?m * MIL-C-C(OS) e 4.3.2 Examinations and tests (a) Visual and dimensional (4.4.2) (b) Copper conductor (4.4.3) (c) Conductor insulation (4.4.4) (d) Cable she
20、athing (4.4.5) (e) (f) Continuity (4.4.7) (g) Capacitance (4.4.8) (h) Room temperature bend (4.4.9) (i) Cold temperature bend (4.4.10) (j) Hydrostatic (4.4.11) Dielectric strength and insulation resistance of cable (4.4.6) 4.3.3 Action in case of failure 4.3.3.1 First article sanple. 6 In the event
21、of the failure of a first article sample to comply with any of the test requirements in accordance with the associated acceptance criteria, the sample under consideration shall be rejected. However, if a test failure occurs as a result of an invalid testing procedure, the original test shall be disc
22、ounted and an additional test shall be conducted in order to determine disposition of the first article sample, Such a rejection shall require that the man- ufacturer review and revise his process procedures and with the approval of the procuring activity submit another first article sample. e 4.3.3
23、.2 Quality conformance sample. In the event of the failure of However, in the event any test sample to comply with the acceptance criteria of 4.3.2 (a), (e), and (f), the lot represented shall be rejected. of the failure of any quality conformance test sample to comply with the acceptance criteria o
24、f 4.3.2 (b), (c), (a), (g), (h), (i), and (j), additional tests shall be run in duplicate on samples from the same cable length. If both additional tests are satisfactory, the lot shall be acceptable. If any failure occurs on the additional tests, the lot shall be rejected, If a test failure occurs
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILC19787C1969CABLEELECTRICTORPEDO65CONDUCTORFORTORPEDOCONTROLSHOW172172 65 导线 鱼雷 电索缆 用于 控制 PDF

链接地址:http://www.mydoc123.com/p-977467.html