1、 MIL-A-82750 7779906 2002633 362 El I i MILITARY SPECIFICATION INCH -POU ND MIL-A-82950(OS) 9 June 1995 ACTUATOR, BELLOWS ATU-l17/P mis specification is approved for use by the Naval Sea asrems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Departmen
2、t of Defense. 1. SCOPE 1.1 Scope. This specification covers the requirements for the Am-1 17/P Bellows Actuator. For the purposes of this specification the term “bellows actuator“ or “actuator“ shall refer to the ATU-l17/P Bellows Actuator (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 Government documents.
3、 2.1.1 Specifications and standards. The following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DOD
4、ISS) and supplements thereto, cited in the solicitation (see 6.2). SPECIFICATIONS FEDERAL QQ-A430 PPP-B-60 1 PPP-B-62 1 Aluminum Alloy Rod and Wire: For Rivets and Cold Heading Boxes, Wood, Cleated-Plywood Boxes, Wood, Nailed and Lock-Corner SPECIFICATIONS MILITARY MIL-D-23615 MIL-1-23659 Design and
5、 Evaluation of Cartridge Actuated Devices General Design Specification for Electric Initiators Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Mian Head Division, Naval Surface Warfar
6、e Center, Standardization Branch (Code 8420), 101 Strauss Avenue, Indian Head, MD 20640-5035, by using the Standardization Document improvement Proposal D Form 1426) appearing at the end of this document or by sending a letter. AMSC NIA FSC 1377 DISTRIBUTION STATEMENT A. Approved for public release;
7、 distribution is unlimited. Licensed by Information Handling Services- MIL-A-82750 W 777770b 2002634 OT7 STANDARDS MILITARY MIL-STD- 129 MIL-STD-453 Inspection, Radiographic MIL-STD-8 10 MIL-STD-1168 Lot Numbering of Ammunition Marking for Shipment and Storage Environmental Test Methods and Engineer
8、ing Guidelines (Unless otherwise indicated, copies of federal and military specifications, standards and handbooks are available from the Naval Publications and Forms Center, Attn: NPODS, 5801 Tabor Avenue, Philadelphia, PA 19 120-5099.) 2.1.2 Other Government documents, drawings and publications. T
9、he following other Government documents, drawings and publications form a part of this specification to the extent specified herein. Unless otherwise specified the issues are those cited in the solicitation (see 6.2). DRAWINGS Naval Air Systems Command (Code 30003) 837AS266 Actuator, Bellows ATU-l17
10、/P Pacific Scientific 2-95 1024 Test Fixture (Application for copies of drawings should be addressed to Commander, Naval Surface Warfare Center, Data Control Branch (Code 8410), Indian Head Division, Indian Head, MD 20640-5035.) CODE OF FEDERAL REGULATIONS (CFR) 49 CFR 100-199 Transportation (Applic
11、ation for copies of CFRs should be addressed to the Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402-0001 .) 2.2 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issue
12、s of the documents which are DOD adopted are those listed in the issue of the DODISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DODISS are the issues of the documents cited in the solicitation (see 6.2). 2 Licensed by Information Handling Service
13、s MIL-A-2950 I 9999706 2002635 T35 AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) D 5118 Fiberboard Shipping Boxes, Standard Practice for Fabrication of (Application for copies should be addressed to the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103-1 187.)
14、2.2 Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQU
15、IREMENTS 3.1 First article. When specified in the contract or purchase order, a sample of bellows actuators shall be subjected to first article inspection (see 4.4 and 6.3) 3.2 Flight critical part. The bellows actuator is a flight critical item and the technical data package shall be identified and
16、 procured as such. 3.3 Design and construction. The following applies to the qualification status and configuration control of the bellows actuator over the entire life of the item. 3.3.1 Identical configuration. The bellows actuator design and construction shall be identical to that subjected to qu
17、alification testing and approved for service use by the Navy. The bellows actuator installed life shall be at least 36 months in the operational environment of -20 to 120F. The shelf life shall be at least 60 months, as calculated from the lot number. 3.3.2 Configuration control. Only bellows actuat
18、ors procured from the vendor(s) listed on drawing 837AS266 are approved for the application specified. A substitute bellows actuator shall not be used without prior approval and testing by the Indian Head Division, Naval Surface Warfare Center, Indian Head, MD 20640-5035 and the Naval Air Systems Co
19、mmand Headquarters. 3.3.3 HERO. The bellows actuator shall be designed to pass the Hazards of Electromagnetic Radiation to Ordnance test. 3.4 Bellows actuator production. Bellows actuators shall be manufactured in accordance with Drawing 837AS266 and this specification. Each production bellows actua
20、tor shall meet the requirements of 3.4.1 through 3.4.6 as outlined in table II. Failure of any bellows actuator to meet these requirements shall result in rejection of that part. The explosive for each production lot shall be from the same explosive lot. 3.4.1 Visual inspection. Bellows actuators sh
21、all be free of the following defects: illegible, missing or inaccurate identification markings, damage, burrs, dents, sharp edges, or other defects which may prevent installation of the bellows actuator into the wedgeltrack assembly (see 4.3.1). 3 Licensed by Information Handling ServicesMIL-A-82950
22、 W 9997906 2002636 971 3.4.2 Radiographic inspection. When radiographically examined in accordance with 4.3.2, the bellows actuator shall show proper assembly, presence of parts, sealing, and proper electrical connections. The radiographic inspection shall show no foreign materials present. 3.4.3 Le
23、akage. The leakage rate of each bellows actuator shall not exceed 1.0 x lo- cc/sec of air when tested in accordance with 4.3.3. 3.4.4 Bridgewire resistance. Bellows actuators shall have a bridgewire resistance of 1.0 dry at ambient conditions for 24 hours; salt fog condition units for 24 hours; dry
24、at ambient conditions for 24 hours. There shall be a total of 48 hours of sait fog conditioning. Each unit shall meet post-test inspections and functional performance requirements. 10 Licensed by Information Handling ServicesMIL-A-82950 E 9999906 2002b23 001 4.3.13 Six-foot drop. Subject the specifi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILA829501995ACTUATORBELLOWSATU117PATU117P 风箱 PDF

链接地址:http://www.mydoc123.com/p-977118.html