1、DOD-D-23443B AMENDMENT 2 27 October 1995 SUPERSEDING AMENDMENT 1 23 September 1985 MILITARY SPECIFICATION DI-(ZETHYLHEXYL) ADIPATE, TECHNICAL (METRIC) This Amendment forms a part of DOD-D-23443B dated 15 May 1978, and is approved for use by all Departments and Agencies of the Department of Defense.
2、PAGE 1 * Delete: “MIL-STD-12 18 ACS Chemicals“ * DD Form 1426 note: Delete “Commanding Officer, Naval Ordnance Station, standardization Division (61 1). Indian Head, MD 20640“ and substitute “Commander, Indian Head Division, Naval Surface Warfare Center, Standardization Branch (Code 8420), Indian He
3、ad, MD 20640- 5035“ Add: “DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.“ * * PAGE 2 2.2: Delete: “ASTM D 94-71 Saponification Number of Petroleum Products“ Add: “ASTM D 1045-86 Sampling and Testing Plasticizers Used in Plastics ASTM D 1209-84 Color of Clear Liquid
4、s (Platinum-Cobalt Scale)“ PAGE 4 4.5: Delete “in accordance with MIL-STD-1218“ at end of paragraph. 4.5.1: Delete: “a. Transfer 1.00 distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-* DOD-D-23443B AMENDMENT 2 NOTE: Do not u
5、se solution after 24 hours. b. Fill a clean 50-mL Nessler tube to the mark with sample plasticizer. Fill another 50-mL Nessler tube to the mark with the standard color solution (a. above). Hold the tubes side by side and compare their colors using transmitted light while looking downward through the
6、 tubes. c. The sample shall be rejected if the color is darker than that of the standard solution.“ Substitute: “a. Prepare a No. 50 Platinum-Cobalt Color Standard in a 100-mL Nessler tube as described in ASTM D 1209-84 (10 mL No. 500 Platinum-Cobalt Stock Solution diluted to 100 mL). The No. 500 Pl
7、atinum-Cobalt Stock Solution, already prepared, is available from laboratory supply houses. It may be used provided it meets the absorbance tolerance limits specified in ASTM D 1209 for the No. 500 Platinum-Cobalt Stock Solution. b. Fill a clean 100-mL Nessler tube to the mark with the plasticizer s
8、ample. c. Hold the sample and standard tubes side by side, and compare their colors using transmitted light while looking downward through the tubes. d. The sample shall be rejected if the color is darker than that of the No. 50 Platinum-Cobalt Standard Solution.“ PAGE 5 4.5.5: Delete first sentence
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYDODD23443B21995DI2ETHYLHEXYLADIPATETECHNICALMETRIC 工业 己二酸 二辛酯 PDF

链接地址:http://www.mydoc123.com/p-976692.html