1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: Commander, Naval Sea Systems Command, ATTN: SEA 05S, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160 or emailed to CommandStandard
2、snavy.mil, with the subject line “Document Comment”. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.dla.mil. AMSC N/A FSC 6099 METRIC A-A-59731B September 25, 2012 SUPERSEDING A-A-59731A October
3、1, 2009 COMMERCIAL ITEM DESCRIPTION TUBE FITTINGS, BLOWN OPTICAL FIBER The General Services Administration has authorized the use of this commercial item description, for all federal agencies. 1. SCOPE. This Commercial Item Description (CID) covers the general requirements for blown optical fiber (B
4、OF) tube fittings (straight tube union couplers, tee tube union couplers, reducer couplers, and end caps) that are used to join together two or more BOF tubes or to terminate a single BOF tube. These tube fittings are designed for use inside shipboard equipment and enclosures. 2. CLASSIFICATION. Tub
5、e fittings shall conform to the following configuration and nominal outer diameter. 2.1 Tube fitting configuration. Tube fittings are of the following configurations: a. U = tube union/straight tube coupler b. T = tube tee/tee tube coupler c. EC = tube end cap d. R = reducing tube straight coupler 2
6、.2 Nominal outer diameter of mating tube. The nominal outer diameter of the mating tube is either 8 millimeters or 5 millimeters. 2.3 Pull performance. Standard or enhanced (see 3.3.1). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59731B 2 3.
7、SALIENT CHARACTERISTICS. 3.1 Design, construction, and dimensions. Design, construction, and dimensions shall be as specified in figures 1, 2, 3, and 4; table I; and table II. FIGURE 1. BOF tube union/straight tube coupler (configuration U). NOTE: C diameter refers to the internal bore diameter (rep
8、resented by dashed lines). A ( se e t a b l e 1 )A ( se e t a b l e 1 )A ( se e t a b l e 1 )B ( se e t a b l e 1 )B ( se e t a b l e 1 )C ( se e t a b l e 1 )D ( se e t a b l e 1 )FIGURE 2. BOF tube tee/tee tube coupler (configuration T / TS). NOTE: C diameter refers to the internal bore diameter (
9、represented by dashed lines). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59731B 3 FIGURE 3. BOF end cap (configuration EC). FIGURE 4. BOF tube reducing straight coupler (configuration R). TABLE I. Tube fitting dimensions. A Dimension Max B D
10、iameter Max C Diameter D Diameter Tube Fitting Configuration 8 mm 5 mm 8 mm 5 mm 8 mm 5 mm 8 mm 5 mm U (tube union/straight tube coupler) 52 40 18.5 12 6.0 - 6.5 3.0 - 3.2 N/A N/A T (tube tee/tee tube coupler) 26 N/A 18.5 N/A 6.0 - 6.5 N/A 6.0 - 6.5 N/A TS (small bore tee tube coupler) 26 N/A 18.5 N
11、/A 6.0 - 6.5 N/A 0.1 N/A EC (tube end cap) 20 20 18.5 12 N/A N/A N/A N/A NOTES: 1. Dimensions are in millimeters. 2. C diameter is tube fitting internal bore diameter. A dimension (see table II) B2 dia (see table II) B1 dia (see table II) C1 dia (see table II) C2 dia (see table II) Provided by IHSNo
12、t for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59731B 4 TABLE II. BOF tube reducing straight coupler dimensions. Tube Fitting Configuration A Dimension Max B Diameter Max C Diameter B1 (8 mm end) B2 (5 mm end) C1 (8 mm end) C2 (5 mm end) R (Reducing tube straigh
13、t coupler) 43 18.5 12 6.0 - 6.5 3.0 - 3.2 NOTES: 1. Dimensions are in millimeters. 2. C diameter is tube fitting internal bore diameter. 3.2 Materials. 3.2.1 Nonmetallic materials. Nonmetallic materials shall not be affected by the use of alcohol based cleaning solutions. Nonmetallic materials shall
14、 not degrade when the tube fitting is operated under the environmental conditions defined herein. 3.2.2 Metallic materials. Metallic materials shall be corrosion resistant. Dissimilar metals shall not be used in intimate contact unless suitably finished to prevent electrolytic corrosion. 3.2.3 Toxic
15、 and hazardous products and formulations. The products used in the tube fitting construction shall not give off toxic or explosive fumes when exposed to flame. Materials used shall have no adverse effect on the health of personnel when used for the intended purpose. 3.2.4 Fungus. When tested in acco
16、rdance with MIL-STD-1678-3, Measurement 3401.1, for a duration of 28 days, tube fitting materials shall show sparse or very restricted microbial growth and reproduction with minor or inhibited substrate utilization. There shall be little or no chemical, physical, or structural change detectable. 3.2
17、.5 Flammability. When tested in accordance with UL 94, the material(s) of the tube fittings external body shall have a rating of V-1. All other components of the tube fitting shall have a rating of HB. 3.2.6 Sealing compounds. If utilized, sealing compounds shall not flow at the maximum specified st
18、orage temperature or exhibit cracking at the minimum specified storage temperature. 3.2.7 Lubricants. If utilized, lubricants used shall be permanent and shall not require replacement during the lifetime of the tube fitting. Lubricants shall be useful over the environmental conditions specified here
19、in. 3.2.8 Tube retention mechanism. Tube retention mechanisms shall utilize metallic materials. 3.3 Mechanical properties. 3.3.1 Tube pull-out. When tested in accordance with TIA-455-6, the tube fitting shall sustain a static tensile load not less than 67 Newtons (15 pounds) applied for 1 minute bet
20、ween the tube fitting and a BOF tube from an approved MIL-PRF-85045/25 or MIL-PRF-85045/26 BOF cable. Tube ends shall be fully seated within the tube fitting at the beginning of the test. The use of retaining clips or equivalent on the tube fitting release mechanism is not allowed. After the test, t
21、he tube fitting shall meet the operational pressure sealing requirements specified herein. Upon visual examination, there shall be no evidence of physical damage detrimental to the operation of the tube fitting or the polymer tube. For enhanced pull performance of straight tube couplers and tee tube
22、 couplers (see 7.2), the movement of the tube end within the tube fitting during the pull test shall be not greater than 0.5 millimeters. 3.3.2 Impact. When dropped eight times onto a steel block from a height of 1.5 meters, tube fittings shall show no visual evidence of physical damage detrimental
23、to the operation of the tube fitting. After the test, the tube fitting shall meet the operational pressure sealing requirements specified herein. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59731B 5 3.3.3 Mating durability. When subjected to
24、10 mate/demate cycles, the tube fitting seals and tube capture mechanisms shall maintain physical integrity. Mated tube fitting/polymer BOF tube (tubing from MIL-PRF-85045/25 or MIL-PRF-85045/26 BOF cable, polyethylene, or equivalent) assemblies shall be used for test purposes. The same tubing shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA59731B2012TUBEFITTINGSBLOWNOPTICALFIBERPDF

链接地址:http://www.mydoc123.com/p-976439.html