1、METRICA-A-5972826 June 2002COMMERCIAL ITEM DESCRIPTIONPLUG, TUBE FITTING, BLOWN OPTICAL FIBERThe General Services Administration has authorizedthe use of this commercial item description (CID).1. SCOPE. This Commercial Item Description (CID) covers the requirements fora tube fitting plug (TFP) which
2、 is used with a tube fitting / tube coupler toseal the ends of empty blown optical fiber (BOF) tubes in tube routing boxes,fiber optic interconnection boxes and equipment, or is used to seal an unusedport of a tube tee.2. CLASSIFICATION. This CID uses a classification system that is includedin the P
3、art or Identification Number (PIN) as shown in the following example(see 7.2).2.1 Part or Identification Number (PIN).AA59728 -TFP-8CID numberNominal outer diameter of mating plug surface (in mm)3. SALIENT CHARACTERISTICS.3.1 Design, construction and dimensions. Design, construction and dimensionssh
4、all be as specified in figure 1.Beneficial comments (recommendations, additions, deletions) and any pertinentdata which may be of use in improving this document should be sent by letterto: Commander, Naval Sea Systems Command, ATTN: SEA 05Q, 1333 Isaac Hull AveSE Stop 5160, Washington Navy Yard, D.C
5、. 20376-5160AMSC N/A FSC 6099DISTRIBUTION STATEMENT A: Approved for public release; distribution isunlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-597282 Figure 1. BOF tube fitting plug.Table 1. Tube fitting plug critical diameter dimen
6、sions.PIN dash number A diameter- TFP 8 8 +0.05 mm-0.1 mm3.2 Materials.3.2.1 Polymer materials. The tube fitting plug shall be fabricated from alow toxicity polymer material. Polymer materials shall not be affected bythe use of alcohol based cleaning solutions. Polymer materials shall notdegrade whe
7、n the tube fitting plug is operated under the environmentalconditions defined herein.3.2.2 Metallic materials. Metallic materials shall not be used.3.2.3 Toxic and hazardous products and formulations. The products used inthe tube fitting plug construction shall not give off toxic or explosivefumes w
8、hen exposed to flame. Materials used shall have no adverse effect onthe health of personnel when used for the intended purpose.3.2.4 Fungus. When tested in accordance with TIA/EIA-455-56 for a durationof 28 days, tube fitting plug materials shall show sparse or very restrictedmicrobial growth and re
9、production with minor or inhibited substrateutilization. There shall be little or no chemical, physical, or structuralchange detectable.3.2.5 Flammability. When tested in accordance with UL-94, tube fitting plugmaterials shall have a rating of HB.3.3 Mechanical properties.3.3.1 Tube fitting plug to
10、tube fitting retention. When subjected to anaxial separation force of 67 N (15 lb) for 1 minute, the tube fitting plugshall remain engaged in a tube fitting compliant with CID A-A-59731. Uponvisual examination, there shall be no evidence of physical damage detrimentalto the operation of the tube fit
11、ting plug.18 mmdia max12 mmmaxAdia(see table 1)30 mm maxProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-597283 3.3.2 Tube fitting plug material tensile strength. When tested in accordancewith ASTM D 638, the tube fitting plug material tensile str
12、ength at yieldshall be not less than 50 N/mm2.3.4 Environmental properties.3.4.1 Temperature ranges. The tube fitting plug shall operate over atemperature range from 28 degrees C to +65 degrees C and shall be capable ofwithstanding storage under temperatures from 40 degrees C to +70 degrees C.3.4.2
13、High temperature tube fitting plug to tube coupler retention. Whensubjected to an axial separation force of 67 N (15 lb) for 1 minute at atemperature of +65 degrees C, the tube fitting plug shall remain engaged in atube coupler compliant with CID A-A-59731. Upon visual examination, thereshall be no
14、evidence of physical damage detrimental to the operation of thetube fitting plug. Damage to the tube fitting plug outer diameter due to thetube coupler tube retention mechanism is acceptable.3.4.3 Life aging. When tested for 240 hours at 110 degrees C in accordancewith EIA/TIA-455-4, the tube fittin
15、g plug shall withstand exposure toaccelerated aging conditions. Upon visual examination, there shall be noevidence of deterioration of component parts or materials, physicaldistortion, cracking, separation of bonded surfaces, or other physical damagedetrimental to the operation of the tube fitting p
16、lug unit. After exposure,the tube fitting plug material tensile strength (see 3.3.2) shall be not lessthan 50% of the unaged tensile strength and the tube fitting plug shall meetthe tube fitting plug to tube coupler retention requirements (see 3.3.1).3.4.4 Storage temperature. When tested for 24 hou
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA597282002PLUGTUBEFITTINGBLOWNOPTICALFIBER 吹制光 纤维 真空管 配件 插座 PDF

链接地址:http://www.mydoc123.com/p-976434.html