1、METRICA-A-59441 16 January 2004 COMMERCIAL ITEM DESCRIPTION VAPOR CORROSION INHIBITORS The General Services Administration has authorized the use of this commercial item description, for all federal agencies. 1. SCOPE. This commercial item description covers the requirements for vapor corrosion inhi
2、bitors (VCIs) to provide corrosion protection for metal components and electrical and electronic assemblies subjected to corrosive environments. The effectiveness of VCIs is governed by the capability to maintain an active molecular layer on the surface of concern. 2. CLASSIFICATION. The VCI materia
3、ls shall be of the following types: Type I - VCI-diffusing devices with adhesive backing. Type II - VCI-diffusing devices without adhesive backing. Type III - VCI packaged in aerosol containers. Type IV - Bulk VCI materials in suspension or liquid form. Type V - Bulk VCI materials in powdered form.
4、Type VI - VCI packaging products. Type VII - VCI impregnated wipes. 3. SALIENT CHARACTERISTICS 3.1 Specification sheets. Individual item requirements shall be as specified herein and in accordance with the applicable specification sheet. In the event of any conflict between the requirements of this
5、commercial item description and the specification sheet, the former shall govern. 3.2 Materials. The VCIs shall be formulated from non-toxic compounds, which are environmentally safe. The VCI compounds, other components and adhesive materials shall not support combustion. Aerosol propellants shall b
6、e non-flammable and non-toxic. VCI formulations and VCI products shall have passed review by the Naval Environmental Health Center (NEHC). In addition VCI compounds and VCI products shall not contain: a) amines and nitrites or nitrates in combination, b) phosphates, or c) silicones. Beneficial comme
7、nts, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: Commander, Naval Sea Systems Command, ATTN: SEA 05Q, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160 or emailed to commandstandardsnavsea.navy.mil
8、, with the subject line “Document Comment”. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at www.dodssp.daps.mil. FSC 2090 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
9、m IHS-,-,-A-A-59441 3.2.1 Material selection. Care must be taken to ensure that the VCI materials selected are approved for the intended use. In the case of Type VI materials used for parts to be placed in storage aboard ship, the materials selected must meet current requirements for the generation,
10、 storage and disposal of waste (residue) at sea. 3.3 Operating environment. The VCI vapor diffusing devices shall retain full functionality for corrosion protection in components and equipment that operate in the temperature range 25 to +65 C. The operating environments for each type of VCI are as f
11、ollows: 3.3.1 Type I. Used in sealed mechanical, electrical and electronic enclosures. Type I VCIs may be used in all equipment: shipboard, land-based, mobile, and aviation. They may also be used in sealed packaging during storage and in transit. 3.3.2 Type II. Used in packaging for protection durin
12、g storage and in transit. Type II VCIs may be used in all equipment: shipboard, land-based, mobile, and aviation. They may also be used in sealed mechanical, electrical and electronic enclosures when no hazard is created by their movement within the enclosure. 3.3.3 Type III. Used in spot applicatio
13、ns in sealed enclosures (medium term protection) and exposed locations (short term or temporary protection). Type III VCIs may be used in all equipment: shipboard, land-based, mobile, and aviation. 3.3.4 Type IV. Used in applications to large components for open storage or transit (medium-term prote
14、ction). Type IV VCIs are normally used in industrial facilities (intermediate or depot-level). 3.3.5 Type V. Used in applications involving large sealed enclosures-tanks or voids (medium to long term protection). Type V VCIs may be used in shipboard, land-based, and mobile applications. 3.3.6 Type V
15、I. Used in applications involving packaging of materials that must be protected from corrosion. They include long term storage and storage in environments that promote corrosion. Type VI VCIs may be used in all packaging and storage applications. 3.3.7 Type VII. Used in applications involving the pe
16、rformance of maintenance upon equipment, for which short-term protection is required while it is exposed to the environment. Type VII VCIs may be used in all applications. 3.4 Performance. As used in individual spec sheets, VCI materials shall protect classes of metals as defined by the following ca
17、tegories: MM Multimetal VCI products inhibit corrosion for all metals normally found exposed in electrical and electronic equipment, as well as mechanical/electromechanical equipment and components. F Ferrous VCI products have been optimized to inhibit corrosion for all ferrous metals found exposed
18、in mechanical, electromechanical, electrical and electronic equipment, including carbon steel, stainless steel, galvanized steel and iron. NF Non-ferrous products have been optimized to inhibit corrosion for all non-ferrous metals normally found exposed in electrical and electronic equipment, as wel
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA594412004VAPORCORROSIONINHIBITORS 蒸汽 腐蚀 抑制剂 PDF

链接地址:http://www.mydoc123.com/p-976410.html