1、A-A-50599 41 9999974 0087253 750 - INCH-POUND A-A- 50599 16 July 1992 COMMERCIAL ITEM DESCRIPTION FAN, TUBEAXIAL, PORTABLE, DESMOKING, AND VENTILATING The General Services administration has authorized the use of this Commercial Item Description. Abstract. This Commercial Item Description specifies
2、requirements for a portable fan that would be used without a ventilation hose to desmoke or ventilate spaces that have direct access to the weather. Salient characteristics. 1. Materials. Materials used in the manufacture of the portable fan shall be non-sparking, corrosion resistant when exposed to
3、 a marine environment, erosion resistant, and shall have no adverse effect on the health of personnel. Fasteners and hardware shall conform to commercial standards and be at least CAE grade 5. Under no circumstances shall self- tapping sheet metal screws be used. In order to prevent galvanic corrosi
4、on, dissimilar metals shall not come in direct contact with each other, except for the fan wheel and insert. Regardless of any other requirements, materials and parts containing cadmium, lithium, mercury, or radioactive material shall not be used. 2. Design and Construction. a. General. The portable
5、 fan shall be free from imperfections or defects of manufacture which may affect its appearance, serviceability, or operation. All exposed edges of the portable fan shall be rounded or chamfered. Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data which may
6、improve this document should be sent to: Commander, Naval Sea Systems Command, SEA 5523, Department of the Navy, Washington, DC 20362-5101. AMSC N/A FSC: 4140 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking
7、permitted without license from IHS-,-,-A-A- 50599 b. Safety. The portable fan shall be provided with fail-safe features that would enhance the safety of personnel while they are operating, maintaining or repairing the fan. When the fan is being operated, maintained, or repaired in accordance with th
8、e manufacturers instructions, there shall be no accessible way for the personnel to receive an electric shock. Provisions of National Fire Protection Association 70 (NFPA) for the designated operational environmental shall apply. c. Size and Weight. The dimensions of the portable fan shall permit it
9、 to pass through a circular opening of 21 inches in diameter. The weight of the portable fan shall not exceed 85 pounds. d. Casing. The casing for the portable fan shall be made cast aluminum or aluminum plate. The casing shall have at least two carrying handles. Two carrying handles shall be along
10、the top of the casing so to allow the fan to be easily transported by two persons. The grip surface of each handle shall be 1 to 1-1/2 inches in width or diameter, and shall be at least six inches in length. All of the handles shall be an integral part of the casing. The portable fan shall have four
11、 feet. Each foot shall be located on the bottom of the fan and shall be an integral part of the portable fan casing. e. Impeller wheel assembly. The impeller wheel shall be of a cast aluminum alloy and shall be securely attached to the motor shaft. The blades of the impeller wheel shall be of an air
12、foil design. The impeller wheel shall have a strength factor of 8 based on the ultimate tensile strength of its material. Balancing of the impeller wheel shall be accomplished by the removal of material from the wheel. If there is insufficient space between the blades to remove the impeller by the u
13、se of an impeller wheel puller, means (such as puller holes) shall be provided in the hub. f. Safety screens. The portable fan shall have safety screens attached at its intake and exhaust openings. Corrosion Resistant Steel (CRES) screws shall be used to install the screens. Safety screens shall be
14、made of a steel CRES wire and shall conform to Underwriters Laboratory 507. g. Security seals. The portable fan shall be provided with security seals to prevent the unauthorized repair of the fan and its motor. The security seals shall be in accordance with MIL-S-23769, type 1, crimp/wire type. h. P
15、reservation. All exposed metal surfaces shall be coated with a thermoset powdered coating using an electrostatic powder technique that conforms to PLASTEC N-18-68. The color of the coating shall be Crimson Red or equivalent. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted with
16、out license from IHS-,-,-A-A-50599 41 9999974 O087255 523 = A-A-50599 i. Welds. The portable fans structure shall have seams and joints that are welded in accordance with chapter 11 or the AWS handbook. Welds shall be visually inspected. 3. Electrical a. Motor. The motor shall have a nominal operati
17、ng voltage of 115 volts with a frequency of 60 hertz and be single phase. A thermal overload protector, in accordance with UL 507, shall be installed in the motor casing. The motor shall start and operate at all motor terminal voltages between 75 and 126 and not cause the thermal overload protector
18、to open. b. Explosion proof. The motor and its associated starting switch shall be mounted in a single explosion proof enclosure and be certified safe to use in class I, group D atmospheres. c. Current. The maximum inrush current shall be 25 amps and shall have a duration of not longer than 3 second
19、s. The maximum running current shall be 7 amps. d. Circuit Resistance to Ground. The circuit resistance between the ground prong and a dummy three prong receptacle ground and each exposed metal part of the fan shall be less than one ohm. The circuit resistance between the attachment electrical plug
20、line prong and each exposed metal part of the fan shall be one megohm or greater. e. Electric cord and Plug. The electric cord and plug shall be in accordance with J-C-175, specifically J-C-l75STIC2BNY, and shall be not less than 50 feet long. All of the conductors shall be 14 AWG, style 1. The plug
21、 connector configuration shall be in accordance with J-C-175, table 1, part number WC596/13-3. The plug connector shall be internally molded to the cable jacket. The electric cord shall be attached to the switch within the casing f. Electrical cord restraint. There shall be a restraint on the electr
22、ic cord to prevent it from being pulled out of the casi-ng. g. Electric Cord Grommets. Where the electric cord penetrates the fan housing, a locking type plastic strain relief shall be used to prevent damage to the cord from rubbing against the housing. 4. Accessories a. Adjustable door bar. The fan
23、 shall have an adjustable door bar. The length of the door bar shall range from 26 to 39 inches and shall not weigh more than 15 pounds. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50599 41 W 9999974 008725b 4bT A-A- 50599 b. Hanger. The fa
24、n shall have a hanger that will be used with the door bar to horizontally or vertically hang the fan from the door. The length of the hanger shall be a minimum of six inches and shall not weigh more than 10 pounds. 5. Operational Orientation. The portable fan shall be able to operate in a horizontal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA505991992FANTUBEAXIALPORTABLEDESMOKINGANDVENTILATING 便携式 抽烟 通风 PDF

链接地址:http://www.mydoc123.com/p-976297.html