GB 3095-1996 Ambien T Air Quality Standard.pdf
《GB 3095-1996 Ambien T Air Quality Standard.pdf》由会员分享,可在线阅读,更多相关《GB 3095-1996 Ambien T Air Quality Standard.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 1National Standard of the Peoples Republic of China Ambient Air Quality Standard (GB3095-1996) 2National Standard of the Peoples Republic of China Ambient Air Quality Standard (GB3095-1996) 1. Subject and Scope This Standard stipulates the designation of functional areas of ambient air quality, sta
2、ndard classification, pollutants, sampling time and concentration limits, sampling and analyzing methods as well as the definition of validity of data statistics. This Standard is applicable to the evaluation of countrywide ambient air quality. 2. Reference Standard GB/T 15262 Air Quality Determinat
3、ion of sulfur dioxide Formaldehyde absorbing- pararosaniline spectrophotometry GB 8970 Air Quality Determination of sulfur dioxide in ambient airTetrachloromercurate (TCM)-pararosaniline method GB/T 5432 Ambient Air Determination of total suspended particles Gravimetric method GB6921 Air Quality Det
4、ermination of the concentration of airborne particulate matters GB/T15436 Ambient Air Determination of nitrogen oxides Saltzman method GB/T15435 Ambient Air Determination of nitrogen dioxides Saltzman method GB/T15437 Ambient Air Determination of ozone Indigo disulphonate spectrophotometry GB/T15438
5、 Ambient Air Determination of ozone Ultraviolet photometric method GB9801 Air Quality Determination of carbon monoxide Non-dispersive infrared spectrometry GB8971 Air Quality Determination of Benzoapyrene in flying dust Acetylated paper chromatography fluoroscene spectrophotometric method GB/T15439
6、Ambient Air Determination of Benzoapyrene in ambient air High performance liquid chromatography GB/T15264 Air Quality Determination of leadFlame atomic absorption spectrophotometric method GB/T15434 Ambient Air Determination of the mass concentration of fluoride Method by filter sampling and fluorin
7、e ion-selective electrode analysis GB/T15433 Ambient Air Determination of the fluoride Method by lime-paper sampling and fluorine ion-selective electrode analysis 3. Definition 3.1 Total suspended particles (TSP): The particles that can be suspended in the air with an aerodynamic equivalent diameter
8、 100 micrometer. 3.2 Breathable particles (PM10): The particles that can be suspended in the air with an aerodynamic equivalent diameter 10 micrometer. 33.3 Nitrogen oxide (as NO2): The nitrogen oxide existing in the air in the form of nitrogen monoxide and nitrogen dioxide. 3.4 Lead (Pb): The lead
9、and its compounds existing in TSP. 3.5 Benzoapyrene (BaP): The benzoapyrene existing in breathable particles. 3.6 Fluoride (as F): Inorganic fluoride existing in gaseous and particulate states. 3.7 Annual average: The arithmetic mean of daily average concentration in any year. 3.8 Quarterly average:
10、 The arithmetic mean of daily average concentration in any quarter. 3.9 Monthly average: The arithmetic mean of daily average concentration in any month. 3.10 Daily average: The average concentration on any day. 3.11 Hourly average: The average concentration in any hour. 3.12 Average in plant growth
11、 season: The arithmetic mean of monthly average concentration in any plant growth season. 3.13 Ambient air: Outside air which human beings, plants, animals, and buildings are exposed to. 3.14 Normal state: The state at a temperature of 273K and a pressure of 101.325Kpa. 4. Grouping and Standard Clas
12、sification of Functional Area of Ambient Air Quality 4.1 Grouping of functional area of ambient air quality Group I area includes natural protection zones, scenic spots and other areas for which special protections are necessary. Group II area includes the residential quarters designated in town pla
13、nning, mixed areas of business, communication and living, cultural areas, normal industrial areas and rural areas. Group III area includes specialized industrial areas. 4.2 Standard classification of ambient air quality The standard of ambient air quality is classified as three classes. Class 1 stan
14、dard is imposed for Group I area. Class 2 standard is imposed for Group II area. Class 3 standard is imposed for Group III area. 5. Concentration Limit This Standard stipulates the concentration limits of various pollutants that are not allowed to be exceeded. For the details, refer to the following
15、 table: 4Table 1 - Concentration Limit for Various Pollutants Concentration limit Pollutant Sampling time Class 1 standard Class 2 standard Class 3 standard Unit of concentration Sulfur dioxide SO2Annual average Daily average Hourly average 0.02 0.05 0.15 0.06 0.15 0.50 0.10 0.25 0.70 Total suspende
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GB 3095 1996 Ambien Air Quality Standard