NAVISTAR MPAPS GT-24-2015 Phosphate System Compatibility.pdf
《NAVISTAR MPAPS GT-24-2015 Phosphate System Compatibility.pdf》由会员分享,可在线阅读,更多相关《NAVISTAR MPAPS GT-24-2015 Phosphate System Compatibility.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2015 by Navistar, Inc. OCTOBER 2015 Page 1 of 7 NAVISTAR, INC. Material, Parts, and Process Specification
2、s (MPAPS) NUMBER: MPAPS GT-24 Former Designation: CEMS GT-24 TITLE: Phosphate System Compatibility CURRENT REV No.: 1510 DATE: OCT. 2015 WRITTEN/EDITED BY: S. Brailey APPROVED BY: R. Goluch SUPERSEDES: CEMS GT-24 April 2009 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION This s
3、pecification may involve hazardous materials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regulatory limits
4、 prior to use. Change Notice: Updated to new format, editorial changes 1.0 APPLICATION This is a method for determining the effect of contaminants (mill oils, drawing compounds, corrosion preventatives, adhesives, sealers, etc.) on the cleaning stages of the phosphate coating system and on the phosp
5、hate coating developed by the system. 2.0 SCOPE This specification covers test methods for high volume contaminants, low volume contaminants, and adhesives and sealers. 2.1 Restricted Chemical Substances Effective January 1, 2007, all product supplied to the requirements of this specification must c
6、omply with the requirements of the MPAPS B-50 specification. 3.0 REFERENCE DOCUMENTS Unless otherwise specified, the latest issue of all referenced standards shall apply. The following Specifications, Standards, and Regulations are referenced in this specification. Quality System Standard ISO 9001 o
7、r TS-16949 CFR Title 29, Part 1910 NAVISTAR MPAPS B-50 NAVISTAR MPAPS G-5 NAVISTAR MPAPS GT-Paint NAVISTAR MPAPS P-9543 4.0 APPARATUS 1. A water bath with capabilities of both heating and agitation suitable to simulate the cleaning stage(s) of the phosphate coating system. 2. Draw bars capable of le
8、aving 0.014 mm (0.54 mil) and 0.019 mm (0.75 mil) wet films - RDS Specialties Rods #6 only the bottom half of each panel is to be topcoated. Use Grade 56 primer and Grade 18 topcoat as per MPAPS G-5. 18. Determine the paint adhesion on both the primer and topcoat on one panel from each group in acco
9、rdance with the method described in MPAPS GT-Paint, method 5A. 19. Perform a humidity test in accordance with MPAPS GT-Paint, method 7E on one panel from each group. 20. Perform a salt spray test in accordance with MPAPS GT-Paint, method 7D on one panel from each group. Report Report the following i
10、nformation: 1. The percent of processing lubricant and water separation at 5 minute, 60 minute, and 24 hour intervals. 2. The percent of water break-free (% WBF) for each metal at each contaminant level and that of the controls. 3. The change in amount of foaming at each contaminant level. 4. The ph
11、osphate coating weight and coating appearance for each control and test panel of each metal at each contaminant level. 5. The minimum percent adhesion observed on each control and test panel of each metal for each of the contaminant levels. 6. Humidity test results for each control and test panel of
12、 each metal for each of the contaminant levels. 7. Salt spray test results for each control and test panel of each metal for each of the contaminant levels. LOW VOLUME CONTAMINANTS Low volume contaminants include but are not limited to miscellaneous lubricants and solvents used to maintain the phosp
13、hate system. Panel Preparation For each metal substrate (CR steel, galvanized steel, 5052-H32 aluminum) to be used in the processing lubricant evaluation: 1. Prepare 4 control panels and 12 test panels for each metal as described High Volume Contaminants, preparation, steps 1 thru 3. 2. Allow the sp
14、ecimens to equilibrate at atmospheric conditions for 2 hrs. prior to testing. Procedure 1. Test for cleanability as described in High Volume Contaminants, procedure, steps 6 thru 13. 2. Test for phosphatability as described in High Volume Contaminants, procedure, steps 14 thru 15. Report 1. The perc
15、ent of water break-free (%WBF) for each metal at each contaminant level and that of the controls. 2. The phosphate coating weight and coating appearance for each control and test panel of each metal at each contaminant level. NUMBER: MPAPS GT-24 TITLE: Phosphate System Compatibility REVISION: 1510 T
16、his document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2015 by Navistar, Inc. OCTOBER 2015 Page 4 of 7 SEALERS AND ADHESIVES This procedure is intended for all s
17、ealers and adhesives that will enter the phosphate system. Panel Preparation Prepare 8 control panels, 8 test panels, and 8 sandwich test panels for each material to be evaluated. 1. Apply the sealer bead of adhesive patch to oiled panels representative of the production conditions. 2. Prepare a set
18、 of sandwich panels with a 6 mm gaps used oiled panels representative of production conditions. 3. Allow the specimens to equilibrate at atmospheric conditions for 2 hours prior to testing. Procedure Re-use the solution for each different set of samples. 1. Record the weight of all the test panels a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVISTARMPAPSGT242015PHOSPHATESYSTEMCOMPATIBILITYPDF

链接地址:http://www.mydoc123.com/p-963023.html