NACE SP0286-1997 Standard Practice Electrical Isolation of Cathodically Protected Pipelines (Item No 21032)《阴极保护管道电气隔离的标准操作规程 项目编号21032》.pdf
《NACE SP0286-1997 Standard Practice Electrical Isolation of Cathodically Protected Pipelines (Item No 21032)《阴极保护管道电气隔离的标准操作规程 项目编号21032》.pdf》由会员分享,可在线阅读,更多相关《NACE SP0286-1997 Standard Practice Electrical Isolation of Cathodically Protected Pipelines (Item No 21032)《阴极保护管道电气隔离的标准操作规程 项目编号21032》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、 Standard Practice Electrical Isolation of Cathodically Protected Pipelines This NACE International standard represents a consensus of those individual members who have reviewed this document, its scope, and provisions. Its acceptance does not in any respect preclude anyone, whether he or she has ad
2、opted the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not in conformance with this standard. Nothing contained in this NACE International standard is to be construed as granting any right, by implication or otherwise, to manufacture, sell,
3、or use in connection with any method, apparatus, or product covered by Letters Patent, or as indemnifying or protecting anyone against liability for infringement of Letters Patent. This standard represents minimum requirements and should in no way be interpreted as a restriction on the use of better
4、 procedures or materials. Neither is this standard intended to apply in all cases relating to the subject. Unpredictable circumstances may negate the usefulness of this standard in specific instances. NACE International assumes no responsibility for the interpretation or use of this standard by othe
5、r parties and accepts responsibility for only those official NACE International interpretations issued by NACE International in accordance with its governing procedures and policies which preclude the issuance of interpretations by individual volunteers. Users of this NACE International standard are
6、 responsible for reviewing appropriate health, safety, environmental, and regulatory documents and for determining their applicability in relation to this standard prior to its use. This NACE International standard may not necessarily address all potential health and safety problems or environmental
7、 hazards associated with the use of materials, equipment, and/or operations detailed or referred to within this standard. Users of this NACE International standard are also responsible for establishing appropriate health, safety, and environmental protection practices, in consultation with appropria
8、te regulatory authorities if necessary, to achieve compliance with any existing applicable regulatory requirements prior to the use of this standard. CAUTIONARY NOTICE: NACE International standards are subject to periodic review, and may be revised or withdrawn at any time in accordance with NACE te
9、chnical committee procedures. NACE International requires that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of initial publication and subsequently from the date of each reaffirmation or revision. The user is cautioned to obtain the latest edi
10、tion. Purchasers of NACE International standards may receive current information on all standards and other NACE International publications by contacting the NACE International First Service Department, 1440 South Creek Dr., Houston, Texas 77084-4906 (telephone +1 281/228-6200). Reaffirmed 2007-03-1
11、0 Reaffirmed 2002-04-11 Revised 1997-June-27 Approved 1986 NACE International 1440 South Creek Drive Houston, Texas 77084-4906 +1 281/228-6200 ISBN 1-57590-041-6 2007, NACE International NACE SP0286-2007 (formerly RP0286) Item no. 21032 SP0286-2007 NACE International i _ Foreword This standard pract
12、ice is to be used in conjunction with the latest revisions of NACE SP01691and SP0177.2Each of these standards refers to electrical isolation or isolation joints, but details are not provided. This standard, which was prepared to supplement those standards, provides engineers, designers, and technica
13、l personnel dealing with pipelines the necessary information to isolate cathodically protected pipelines electrically. This standard was originally prepared in 1986 and revised in 1997 by former Task Group T-10A-15 on Electrical Isolation of Cathodically Protected Pipelines, a component of Unit Comm
14、ittee T-10A on Cathodic Protection. The standard was reaffirmed in 2002 and 2007 by Specific Technology Group (STG) 35 on Pipelines, Tanks, and Well Casings. It is issued by NACE International under the auspices of STG 35. In NACE Standards, the terms shall, must, should, and may are used in accorda
15、nce with the definitions of these terms in the NACE Publications Style Manual, 4th ed., Paragraph 7.4.1.9. Shall and must are used to state mandatory requirements. The term should is used to state something good and is recommended but is not mandatory. The term may is used to state something conside
16、red optional. _ SP0286-2007 ii NACE International _ NACE International Standard Practice Electrical Isolation of Cathodically Protected Pipelines Contents 1. General . 1 2. Definitions . 1 3. Need for Isolation1 4. Methods of Isolation 2 5. Isolation from Other Metallic Structures 7 6. Selection of
17、Isolation Device or Method . 9 7. Equipment Specifications 9 8. Equipment Installation. 12 9. Field Testing and Maintenance. 15 References 17 FIGURES Figure 1a: Full-Length Bolt Sleeves 2 Figure 1b: Half-Length Bolt Sleeves 2 Figure 2: Typical Isolating Monolithic Device 3 Figure 3: Typical Isolatin
18、g Monolithic Joint 3 Figure 4: Typical Isolating Yoke-Type Device . 4 Figure 5: Typical Isolating Union . 5 Figure 6: Typical Isolating Spools 5 Figure 7: Typical Isolating Couplings. 6 Figure 8: Typical Isolating Tapping Sleeve 7 Figure 9: Typical Casing/Sleeve Installation 7 Figure 10: Typical Use
19、 of Isolating Devices at Each End of a Bridge for a Cathodically Protected Pipeline. 8 Figure 11: Isolating Joint Test Station . 12 Figure 12: Isolating Device Leakage Test . 16 _ SP0286-2007 NACE International 1 _ Section 1: General 1.1 This standard explains the importance of pipeline electrical i
20、solation in achieving and maintaining adequate, reliable, and economical corrosion control. The standard outlines the types of devices used for isolation; precautions to be observed; and selection of devices based on pipeline characteristics, site, and contents. The standard describes isolating flan
21、ges, gaskets, sleeves, washers, joints, unions, couplings, and spools, and discusses materials for pipeline casing isolation. Installation, field testing, and maintenance of isolating devices are also included. 1.2 This standard describes the application of isolating devices intended only for cathod
22、ic protection (CP) purposes when voltages across the isolating device are 1 to 2 volts direct current (DC) and the alternating current (AC) exposure does not exceed 15 volts root mean square (rms).31.3 This standard does not discuss situations in which isolating devices are incorporated purely for s
23、afety reasons; in those situations, reference should be made to relevant electrical safety codes. Isolating devices shall not be used in enclosed areas where combustible atmospheres are likely to be present. 1.4 Isolation of cathodically protected pipelines is recommended to minimize current require
24、ments, facilitate testing and troubleshooting, and improve current distribution. _ Section 2: Definitions Refer to the NACE International Glossary of Corrosion-Related Terms4for definitions. _ Section 3: Need for Isolation 3.1 CP current intended for a given pipeline can flow to other underground fa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NACESP02861997STANDARDPRACTICEELECTRICALISOLATIONOFCATHODICALLYPROTECTEDPIPELINESITEMNO21032 阴极保护 管道

链接地址:http://www.mydoc123.com/p-835831.html