NACE SP0207-2007 Performing Close-Interval Potential Surveys and DC Surface Potential Gradient Surveys on Buried or Submerged Metallic Pipelines (Item No 21121)《在水下或水下金属管道上执行关闭间隔潜在.pdf
《NACE SP0207-2007 Performing Close-Interval Potential Surveys and DC Surface Potential Gradient Surveys on Buried or Submerged Metallic Pipelines (Item No 21121)《在水下或水下金属管道上执行关闭间隔潜在.pdf》由会员分享,可在线阅读,更多相关《NACE SP0207-2007 Performing Close-Interval Potential Surveys and DC Surface Potential Gradient Surveys on Buried or Submerged Metallic Pipelines (Item No 21121)《在水下或水下金属管道上执行关闭间隔潜在.pdf(51页珍藏版)》请在麦多课文档分享上搜索。
1、 Standard Practice Performing Close-Interval Potential Surveys and DC Surface Potential Gradient Surveys on Buried or Submerged Metallic Pipelines This NACE International standard represents a consensus of those individual members who have reviewed this document, its scope, and provisions. Its accep
2、tance does not in any respect preclude anyone, whether he or she has adopted the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not in conformance with this standard. Nothing contained in this NACE International standard is to be construed as
3、granting any right, by implication or otherwise, to manufacture, sell, or use in connection with any method, apparatus, or product covered by Letters Patent, or as indemnifying or protecting anyone against liability for infringement of Letters Patent. This standard represents minimum requirements an
4、d should in no way be interpreted as a restriction on the use of better procedures or materials. Neither is this standard intended to apply in all cases relating to the subject. Unpredictable circumstances may negate the usefulness of this standard in specific instances. NACE International assumes n
5、o responsibility for the interpretation or use of this standard by other parties and accepts responsibility for only those official NACE International interpretations issued by NACE International in accordance with its governing procedures and policies which preclude the issuance of interpretations
6、by individual volunteers. Users of this NACE International standard are responsible for reviewing appropriate health, safety, environmental, and regulatory documents and for determining their applicability in relation to this standard prior to its use. This NACE International standard may not necess
7、arily address all potential health and safety problems or environmental hazards associated with the use of materials, equipment, and/or operations detailed or referred to within this standard. Users of this NACE International standard are also responsible for establishing appropriate health, safety,
8、 and environmental protection practices, in consultation with appropriate regulatory authorities if necessary, to achieve compliance with any existing applicable regulatory requirements prior to the use of this standard. CAUTIONARY NOTICE: NACE International standards are subject to periodic review,
9、 and may be revised or withdrawn at any time in accordance with NACE technical committee procedures. NACE International requires that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of initial publication and subsequently from the date of each re
10、affirmation or revision. The user is cautioned to obtain the latest edition. Purchasers of NACE International standards may receive current information on all standards and other NACE International publications by contacting the NACE International First Service Department, 1440 South Creek Dr., Hous
11、ton, Texas 77084-4906 (telephone +1 281/228-6200). Approved 2007-03-10 NACE International 1440 South Creek Drive Houston, Texas 77084-4906 +1 281/228-6200 ISBN 1-57590-211-7 2007, NACE International NACE SP0207-2007 Item No. 21121 SP0207-2007 NACE International i _ Foreword This standard practice pr
12、esents procedures for performing close-interval direct current (DC) structure-to-electrolyte potential surveys, DC surface potential gradient surveys, and hybrid surveys such as trailing-wire direct current voltage gradient (DCVG) surveys or intensive measurement surveys, on buried or submerged meta
13、llic pipelines. Cell-to-cell surveys used to evaluate coating effectiveness are described in other NACE publications.1This standard is intended for use by corrosion control personnel involved with operating pipelines, contractors performing close-interval survey (CIS) and other surveys, corrosion pr
14、ofessionals interpreting CIS and other survey data, and regulatory agencies. Included are definitions, pre-job considerations, instrumentation and equipment guidelines, methods for IR drop correction, pipe location and marking procedures, survey procedures, hybrid survey procedures, offshore and dyn
15、amic stray-current survey procedures, cell-to-cell surface potential gradient surveys, and data validity and post-job considerations. For accurate and correct application, this standard must be used in its entirety. Using or citing only specific paragraphs or sections can lead to misinterpretation a
16、nd misapplication of the recommendations and practices presented. Specific practices are not designated for every situation because of the complexity of conditions to which buried or submerged piping systems are exposed. This standard was prepared by Task Group (TG) 279 on Pipelines: Close-Interval
17、Potential Surveys on Buried or Submerged Metallic Pipelines. TG 279 is administered by Specific Technology Group (STG) 35 on Pipelines, Tanks, and Well Casings, and sponsored by STG 05 on Cathodic/Anodic Protection. This standard is issued by NACE International under the auspices of STG 35. In NACE
18、standards, the terms shall, must, should, and may are used in accordance with the definitions of these terms in the NACE Publications Style Manual, 4th ed., Paragraph 7.4.1.9. Shall and must are used to state mandatory requirements. The term should is used to state something good and is recommended
19、but is not mandatory. The term may is used to state something considered optional. _ SP0207-2007 ii NACE International _ NACE International Standard Practice Performing Close-Interval Potential Surveys and DC Surface Potential Gradient Surveys on Buried or Submerged Metallic Pipelines Contents 1. Ge
20、neral . 1 2. Definitions . 3 3. Pre-Job Considerations 7 4. Instrumentation and Equipment 9 5. Minimizing IR Drop . 11 6. Pipe Location and Marking Procedures 16 7. CIS Procedures 18 8. Hybrid CIS Procedures . 22 9. Offshore Close-Interval Survey Procedures . 23 10. Dynamic Stray Current Considerati
21、ons 25 11. DC Cell-to-Cell Surface Potential Gradient Surveys. 28 12. Data Validity and Post-Job Analysis . 32 References 35 Bibliography 35 Appendix A: Pipe IR Drop Calculation (Nonmandatory). 36 Figure 1: Dynamic Stray Current as a Result of Electric Transit System. 26 Figure 2: Dynamic Stray Curr
22、ent as a Result of Telluric Currents . 27 Figure 3: Hot-Spot Survey 31 Figure 4: Side-Drain Survey . 31 Figure 5: Plot of “On” and Instant-Off Potentials vs. Distance with Scatter 33 Figure 6: Plot of “On” and Instant-Off Potentials vs. Distance with Unmatched Reference Electrodes . 34 _ SP0207-2007
23、 NACE International 1 _ Section 1: General 1.1 Introduction 1.1.1 This standard defines the requirements for performing close-interval potential surveys and DC surface potential gradient surveys on buried or submerged metallic pipelines. For the purposes of this standard, the terms close-interval po
24、tential survey (CIPS) and close-interval survey (CIS) are used interchangeably. Procedures for performing hybrid close-interval surveys are given in Section 8. Procedures for performing CIS in marine conditions are given in Section 9. Considerations for dynamic stray current are given in Section 10.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NACESP02072007PERFORMINGCLOSEINTERVALPOTENTIALSURVEYSANDDCSURFACEPOTENTIALGRADIENTSURVEYSONBURIEDORSUBMERGEDMETALLICPIPELINESITEMNO21121

链接地址:http://www.mydoc123.com/p-835822.html