NACE SP0196-2015 Galvanic Anode Cathodic Protection of Internal Submerged Surfaces of Steel Water Storage Tanks (Item No 21077).pdf
《NACE SP0196-2015 Galvanic Anode Cathodic Protection of Internal Submerged Surfaces of Steel Water Storage Tanks (Item No 21077).pdf》由会员分享,可在线阅读,更多相关《NACE SP0196-2015 Galvanic Anode Cathodic Protection of Internal Submerged Surfaces of Steel Water Storage Tanks (Item No 21077).pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、 Standard Practice Galvanic Anode Cathodic Protection of Internal Submerged Surfaces of Steel Water Storage Tanks This NACE International standard represents a consensus of those individual members who have reviewed this document, its scope, and provisions. Its acceptance does not in any respect pre
2、clude anyone, whether he or she has adopted the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not in conformance with this standard. Nothing contained in this NACE International standard is to be construed as granting any right, by implicatio
3、n or otherwise, to manufacture, sell, or use in connection with any method, apparatus, or product covered by Letters Patent, or as indemnifying or protecting anyone against liability for infringement of Letters Patent. This standard represents minimum requirements and should in no way be interpreted
4、 as a restriction on the use of better procedures or materials. Neither is this standard intended to apply in all cases relating to the subject. Unpredictable circumstances may negate the usefulness of this standard in specific instances. NACE International assumes no responsibility for the interpre
5、tation or use of this standard by other parties and accepts responsibility for only those official NACE International interpretations issued by NACE International in accordance with its governing procedures and policies which preclude the issuance of interpretations by individual volunteers. Users o
6、f this NACE International standard are responsible for reviewing appropriate health, safety, environmental, and regulatory documents and for determining their applicability in relation to this standard prior to its use. This NACE International standard may not necessarily address all potential healt
7、h and safety problems or environmental hazards associated with the use of materials, equipment, and/or operations detailed or referred to within this standard. Users of this NACE International standard are also responsible for establishing appropriate health, safety, and environmental protection pra
8、ctices, in consultation with appropriate regulatory authorities if necessary, to achieve compliance with any existing applicable regulatory requirements prior to the use of this standard. CAUTIONARY NOTICE: NACE International standards are subject to periodic review, and may be revised or withdrawn
9、at any time in accordance with NACE technical committee procedures. NACE International requires that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of initial publication. The user is cautioned to obtain the latest edition. Purchasers of NACE In
10、ternational standards may receive current information on all standards and other NACE International publications by contacting the NACE International FirstService Department, 15835 Park Ten Place, Houston, Texas 77084-5145 (telephone +1 281-228-6200). Revised 2015-11-28 NACE International 15835 Park
11、 Ten Place Houston, TX 77084-5145 +1 281-228-6200 ISBN 1-5790-189-7 2015 NACE International NACE SP0196-2015 Item No. 21077 SP0196-2015 i NACE International _ Foreword The purpose of this standard is to present the standard practices used in providing galvanic anode cathodic protection (CP) to the n
12、ormally submerged steel surfaces inside steel water storage tanks. This standard provides owners, engineers, and contractors with guidelines for the application of CP to the submerged surfaces of steel water storage tanks; for determining the effectiveness of these CP systems; and for the operation
13、and maintenance of these CP systems. This standard is applicable to steel water storage tanks of various sizes used in municipal water supply and fire protection, including elevated tanks and flat-bottom tanks at ground level. Although the practices presented in this standard generally are applicabl
14、e to all such tanks, the galvanic anode CP system described in this standard may not be practical for relatively large tanks. This standard was originally prepared in 1996 by NACE Task Group (TG) T-7L-1, a component of Unit Committee T-7L, “Cathodic Protection.” It was revised in 2004, 2011, and 201
15、5 by TG 284, “Cathodic Protection, Galvanic Anode for Internal Submerged Surfaces of Steel Water Storage TanksReview of NACE SP0196.” TG 284 is administered by Specific Technology Group (STG) 05, “Cathodic/Anodic Protection.” It is sponsored by STG 11, “Water Treatment,” and STG 35, “Pipelines, Tank
16、s, and Well Casings.” This standard is issued by NACE under the auspices of STG 05. In NACE standards, the terms shall, must, should, and may are used in accordance with the definitions of these terms in the NACE Publications Style Manual. The terms shall and must are used to state a requirement, an
17、d are considered mandatory. The term should is used to state something good and is recommended, but is not considered mandatory. The term may is used to state something considered optional. SP0196-2015 NACE International ii _ NACE International Standard Practice Galvanic Anode Cathodic Protection of
18、 Internal Submerged Surfaces of Steel Water Storage Tanks Contents 1. General 1 2. Definitions 1 3. Determination of Need for Cathodic Protection . 2 4. Design of Galvanic Anode Cathodic Protection Systems . 3 5. Installation of Galvanic Anode Cathodic Protection Systems . 7 6. Criteria for Cathodic
19、 Protection . 7 7. Operation and Maintenance 9 References 11 Appendix A: Tanks and Vessels Containing Other Waters (Nonmandatory) 12 TABLES Table 1: Typical Galvanic Anode Materials and Characteristics. 5 _ NACE International 1 _ Section 1: General 1.1 This standard presents standard practices for u
20、sing galvanic anodes to apply CP to the internal submerged surfaces of steel tanks used for the storage of potable and reclaimed water, drinking water, irrigation water, and fire protection water. Appendix A (nonmandatory) provides guidance for the use of CP for the internal surfaces of tanks and ve
21、ssels containing other waters. 1.2 Impressed current CP systems are used extensively for the internal surfaces of water storage tanks; however, this standard addresses only galvanic anode CP systems. For a description of impressed current CP systems, refer to NACE SP0388.1 1.3 The ground level and e
22、levated storage tanks considered in this standard are of welded, bolted, or riveted-steel construction, and include many shapes and sizes. 1.4 CP as described in this standard may be used alone to control corrosion of submerged steel surfaces or may be used as a complement to the protection provided
23、 by protective coatings or other procedures.2 CP cannot protect surfaces that are not submerged; these surfaces are typically protected by coatings alone. 1.5 CP may be installed to control corrosion in both newly constructed and existing tanks. When CP is used on existing tanks, it may be necessary
24、 to drain the tank during installation. 1.6 Tanks under consideration for application of CP are often associated with potable water and fire protection systems that may be subject to public health and safety regulations.3 This standard shall not infringe on those regulations. Proper disinfection of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NACESP01962015GALVANICANODECATHODICPROTECTIONOFINTERNALSUBMERGEDSURFACESOFSTEELWATERSTORAGETANKSITEMNO21077PDF

链接地址:http://www.mydoc123.com/p-835816.html