MSS SP-150-2015 Valves for Use in Hydrogen Peroxide Service.pdf
《MSS SP-150-2015 Valves for Use in Hydrogen Peroxide Service.pdf》由会员分享,可在线阅读,更多相关《MSS SP-150-2015 Valves for Use in Hydrogen Peroxide Service.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、MSS SP-150-2015 Valves for Use in Hydrogen Peroxide Service Standard Practice Developed and Approved by the Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. 127 Park Street, NE Vienna, Virginia 22180-4602 Phone: (703) 281-6613 Fax: (703) 281-6671 E-mail: standardsmsshq.
2、org www.msshq.org MSS STANDARD PRACTICE SP-150i This MSS Standard Practice was developed under the consensus of the MSS Technical Committee 407, Committee 304, and the MSS Coordinating Committee. The content of this Standard Practice is the resulting efforts of competent and experienced volunteers t
3、o provide an effective, clear, and non-exclusive standard that will benefit the industry as a whole. This MSS Standard Practice describes minimal requirements and is intended as a basis for common practice by the manufacturer, the user, and the general public. The existence of an MSS Standard Practi
4、ce does not in itself preclude the manufacture, sale, or use of products not conforming to the Standard Practice. Mandatory conformance to this Standard Practice is established only by reference in other documents such as a code, specification, sales contract, or public law, as applicable. MSS has n
5、o power, nor does it undertake, to enforce or certify compliance with this document. Any certification or other statement of compliance with the requirements of this Standard Practice shall not be attributable to MSS and is solely the responsibility of the certifier or maker of the statement. “Unles
6、s indicated otherwise within this MSS Standard Practice, other standards documents referred to herein are identified by the date of issue that was applicable to this Standard Practice at the date of approval of this MSS Standard Practice (see Annex A). This Standard Practice shall remain silent on t
7、he validity of those other standards of prior or subsequent dates of issue even though applicable provisions may not have changed.” By publication of this Standard Practice, no position is taken with respect to the validity of any potential claim(s) or of any patent rights in connection therewith. M
8、SS shall not be held responsible for identifying any patent rights. Users are expressly advised that determination of patent rights and the risk of infringement of such rights are entirely their responsibility. In this Standard Practice all text, notes, annexes, tables, figures, and references are c
9、onstrued to be essential to the understanding of the message of the standard, and are considered normative unless indicated as “supplemental“. All appendices, if included, that appear in this document are construed as “supplemental“. Note that “supplemental” information does not include mandatory re
10、quirements. U.S. customary units in this Standard Practice are the standard; (SI) metric units are for reference only. Non-toleranced dimensions in this Standard Practice are nominal unless otherwise specified. Any excerpts of this Standard Practice may be quoted with permission. Credit lines should
11、 read Extracted from MSS SP-150-2015 with permission of the publisher, Manufacturers Standardization Society of the Valves and Fittings Industry. Reproduction and/or electronic transmission or dissemination is prohibited under copyright convention unless written permission is granted by the Manufact
12、urers Standardization Society of the Valve and Fittings Industry Inc. All rights reserved. Originally Approved: August 2015 Originally Published: December 2015 MSS is a registered trademark of Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. Copyright , 2015 by Manufact
13、urers Standardization Society of the Valve and Fittings Industry, Inc. Printed in U.S.A. MSS STANDARD PRACTICE SP-150ii TABLE OF CONTENTS SECTION PAGE 1 SCOPE 1 2 DEFINITIONS . 1 3 GENERAL REQUIREMENTS 1 4 MATERIALS OF CONSTRUCTION 1 5 PASSIVATION 2 6 CLEANING 2 7 ASSEMBLY . 3 8 TESTING 3 9 PACKAGIN
14、G . 3 10 MARKING . 3 11 ACCEPTANCE CRITERIA . 3 ANNEX A Referenced Standards and Applicable Dates . 4 MSS STANDARD PRACTICE SP-1501 VALVES FOR USE IN HYDROGEN PEROXIDE SERVICE 1. SCOPE This Standard Practice contains requirements for material, design, fabrication, pressure testing, marking, and prep
15、aration for shipment of valves for use in hydrogen peroxide (H2O2) service. 2. DEFINITIONS 2.1 Cavity Any area in the valve that has the potential to entrap pressure when the valve is opened or closed. 2.2 Cavity Vent A method for release of entrapped pressure in cavities that may occur when the val
16、ve is opened or closed. 2.3 Hydrogen Peroxide A chemical compound with the formula H2O2. Thermal and other precautions should be observed. See the applicable material safety data sheet (MSDS). 2.4 Passivation The process of making a material non-reactive (passive) in relation to another material pri
17、or to using the materials together. 2.5 Other Definitions Other definitions may be found in MSS SP-96. 3. GENERAL REQUIREMENTS 3.1 Pressure boundary parts of the valve and all internal parts that can contact the media contained within the valve shall be made of the materials specified herein. 3.2 Ex
18、ternal parts that do not normally come into contact with the media contained inside the valve (such as glands, packing nut, external bolting) shall be made of materials compatible with the pressure boundary parts. 3.3 Valves containing cavities that may entrap hydrogen peroxide when the valve is ful
19、ly open or shut (such as ball and gate valves) shall have cavity vent holes machined in the parts to enable release of pressure. Cavity vent holes shall be a minimum of 1/8 inch (3 mm). A flow direction arrow shall be marked on the valve body if the cavity vent hole(s) permit shut-off in only one di
20、rection of flow. 3.4 Passivation, cleaning, assembly, inspection, post-clean testing, marking, and packaging shall be conducted by properly trained and qualified personnel knowledgeable of this Standard Practice and the materials utilized. 4. MATERIALS OF CONSTRUCTION 4.1 Valve bodies and trim parts
21、 shall be made from either: (1) 356 high purity aluminum alloy, or (2) 304 austenitic stainless steel, or (3) 316 austenitic stainless steel, or (4) wrought or cast equivalents of above. 4.1.1 Low carbon Type 304L and 316L Grades shall be used if the valve construction requires fabrication welds. 4.
22、2 Wetted surfaces of parts made from cast material shall be free of blow holes, inclusions or porosity that could contain or entrap incompatible debris. MSS STANDARD PRACTICE SP-1502 4.3 Valve seats and seals shall be either pure Polytetrafluoroethylene (PTFE), glass filled PTFE, or Polychlorotriflu
23、orethylene (PCTFE). Fluoroelastomer O-rings and gaskets can also be used for seals. 4.4 Graphitic seals are generally considered incompatible with hydrogen peroxide. Graphite will increase the rate of decomposition of hydrogen peroxide. NOTE: Use of graphitic seals may be necessary for fire-safe val
24、ve construction and may be acceptable for some applications. Graphitic seals may only be used when fire-safe valve construction is requested, and use of graphitic material is approved by the purchaser. 4.5 Certain combined fluorine/chlorine or comparable lubricants may be compatible with hydrogen pe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- MSSSP1502015VALVESFORUSEINHYDROGENPEROXIDESERVICEPDF

链接地址:http://www.mydoc123.com/p-822989.html