JEDEC J-STD-035-1999 Acoustic Microscopy for Nonhermetic Encapsulated Electronic Components《非气密封装电子元件用声波显微镜》.pdf
《JEDEC J-STD-035-1999 Acoustic Microscopy for Nonhermetic Encapsulated Electronic Components《非气密封装电子元件用声波显微镜》.pdf》由会员分享,可在线阅读,更多相关《JEDEC J-STD-035-1999 Acoustic Microscopy for Nonhermetic Encapsulated Electronic Components《非气密封装电子元件用声波显微镜》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、JOINTINDUSTRYSTANDARDAcousticMicroscopyforNonhermeticEncapsulatedElectronicComponentsIPC/JEDECJ-STD-035MAY 1999 Reaffirmed September 2010NOTICEEIA/JEDEC standards and publications contain material that has been prepared, reviewed, andapproved through the JEDEC Board of Directors level and subsequent
2、ly reviewed and approvedby the EIA General Counsel.EIA/JEDEC standards and publications are designed to serve the public interest througheliminating misunderstandings between manufacturers and purchasers, facilitatinginterchangeability and improvement of products, and assisting the purchaser in sele
3、cting andobtaining with minimum delay the proper product for use by those other than JEDEC members,whether the standard is to be used either domestically or internationally.EIA/JEDEC standards and publications are adopted without regard to whether or not theiradoption may involve patents or articles
4、, materials, or processes. By such action JEDEC does notassume any liability to any patent owner, nor does it assume any obligation whatever to partiesadopting the EIA/JEDEC standards or publications.The information included in EIA/JEDEC standards and publications represents a sound approachto produ
5、ct specification and application, principally from the solid state device manufacturerviewpoint. Within the JEDEC organization there are procedures whereby an EIA/JEDECstandard or publication may be further processed and ultimately become an ANSI/EIA standard.No claims to be in conformance with this
6、 standard may be made unless all requirements stated inthe standard are met.Inquiries, comments, and suggestions relative to the content of this EIA/JEDEC standard orpublication should be addressed to JEDEC Solid State Technology Association, 2500 WilsonBoulevard, Arlington, VA 22201-3834, (703)907-
7、7560/7559 or www.jedec.orgPublished by ELECTRONIC INDUSTRIES ALLIANCE 1999Engineering Department2500 Wilson BoulevardArlington, VA 22201-3834This document may be downloaded free of charge, however EIA retains thecopyright on this material. By downloading this file the individual agrees not tocharge
8、or resell the resulting material.PRICE: IPC/JEDEC Members: $18.00, Non-Members: $35.00Printed in the U.S.A.All rights reservedPLEASE!DON”T VIOLATETHELAW!This document is copyrighted by the Electronic Industries Alliance and may not bereproduced without permission.Organizations may obtain permission
9、to reproduce a limited number of copiesthrough entering into a license agreement. For information, contact:JEDEC Solid State Technology Association2500 Wilson BoulevardArlington, Virginia 22201-3834or call (703) 907-7559Joint IPC/JEDEC Standard J-STD-035Page 1ACOUSTIC MICROSCOPY FOR NONHERMETICENCAP
10、SULATED ELECTRONIC COMPONENTS(From JEDEC Board Ballot JCB-98-99, under the cognizance of the JC-14.1 Committee on ReliabilityTest Methods for Packaged Devices an with the IPC.)1 ScopeThis test method defines the procedures for performing acoustic microscopy on nonhermetic encapsulatedelectronic comp
11、onents. This method provides users with an acoustic microscopy process flow fordetecting anomalies (delamination, cracks, mold compound voids, etc.) nondestructively in plasticpackages while achieving reproducibility.2 Definitions2.1 A-modeAcoustic data collected at the smallest X-Y-Z region defined
12、 by the limitations of the given acousticmicroscope. An A-mode display contains amplitude and phase/polarity information as a function of timeof flight at a single point in the X-Y plane. See Figure 1 - Example of A-mode Display.Figure 1 Example of A-mode Display2.2 B-modeAcoustic data collected alo
13、ng an X-Z or Y-Z plane versus depth using a reflective acoustic microscope. AB-mode scan contains amplitude and phase/polarity information as a function of time of flight at eachpoint along the scan line. A B-mode scan furnishes a two-dimensional (cross-sectional) description alonga scan line (X or
14、Y). See Figure 2 - Example of B-mode Display.Joint IPC/JEDEC Standard J-STD-035Page 22.2 B-mode (contd)Figure 2 Example of B-mode Display (bottom half of picture on left)2.3 Back-Side Substrate View Area (Refer to Annex A, Type IV)The interface between the encapsulant and the back of the substrate w
15、ithin the outer edges of the substratesurface.2.4 C-modeAcoustic data collected in an X-Y plane at depth (Z) using a reflective acoustic microscope. A C-modescan contains amplitude and phase/polarity information at each point in the scan plane. A C-mode scanfurnishes a two-dimensional (area) image o
16、f echoes arising from reflections at a particular depth (Z). SeeFigure 3.Figure 3 Example of C-mode DisplayJoint IPC/JEDEC Standard J-STD-035Page 32.5 Through Transmission ModeAcoustic data collected in an X-Y plane throughout the depth (Z) using a through transmission acousticmicroscope. A Through
17、Transmission mode scan contains only amplitude information at each point inthe scan plane. A Through Transmission scan furnishes a two-dimensional (area) image of transmittedultrasound through the complete thickness/depth (Z) of the sample/component. See Figure 4 Exampleof Through Transmission Displ
18、ay.Figure 4 Example of Through Transmission Display2.6 Die Attach View Area (Refer to Annex A, Type II)The interface between the die and the die attach adhesive and/or the die attach adhesive and the die attachsubstrate.2.7 Die Surface View Area (Refer to Annex A, Type I)The interface between the en
19、capsulant and the active side of the die.2.8 Focal Length (FL)The distance in water at which a transducers spot size is at a minimum.2.9 Focus PlaneThe X-Y plane at a depth (Z), which the amplitude of the acoustic signal is maximized.2.10 Leadframe (L/F) View Area (Refer to Annex A, Type V)The image
20、d area which extends from the outer L/F edges of the package to the L/F “tips” (wedgebond/stitch bond region of the innermost portion of the L/F.)Joint IPC/JEDEC Standard J-STD-035Page 42.11 Reflective Acoustic MicroscopeAn acoustic microscope that uses one transducer as both the pulser and receiver
21、. (This is also known as apulse/echo system.) See Figure 5 - Diagram of a Reflective Acoustic Microscope.Figure 5 Diagram of a Reflective Acoustic Microscope System2.12 Through Transmission Acoustic MicroscopeAn acoustic microscope that transmits ultrasound completely through the sample from a sendi
22、ngtransducer to a receiver on the opposite side. See Figure 6 - Diagram of a Through Transmission AcousticMicroscope System.Figure 6 Diagram of a Through Transmission Acoustic Microscope System2.13 Time-of-Flight (TOF)a) In reflective mode, the time of flight is the time it takes for the acoustic pu
23、lse to travel from a singletransducer/receiver to the interface of interest and back.b) In through transmission mode, the time of flight is the time it takes for the acoustic pulse to travelfrom the sending transducer through the sample to the receiving transducer.2.14 Top-Side Die Attach Substrate
24、View Area (Refer to Annex A, Type III)The interface between the encapsulant and the die side of the die attach substrate surrounding the die.X-Y-ZScanning SystemPulser/ReceiverFluid Medium BathTransducerA-mode Display Computer ControllerX-Y-ZScanning System PulserReceiverFluid Medium BathTransducer
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JEDECJSTD0351999ACOUSTICMICROSCOPYFORNONHERMETICENCAPSULATEDELECTRONICCOMPONENTS 气密 封装 电子元件 声波 显微镜 PDF

链接地址:http://www.mydoc123.com/p-806936.html