ITU-T O 95-1988 PHASE AND AMPLITUDE HIT COUNTERS FOR TELEPHONE-TYPE CIRCUITS《相位和幅度击中柜台 电话型电路-规格为测量设备 第4研究组 共4页》.pdf
《ITU-T O 95-1988 PHASE AND AMPLITUDE HIT COUNTERS FOR TELEPHONE-TYPE CIRCUITS《相位和幅度击中柜台 电话型电路-规格为测量设备 第4研究组 共4页》.pdf》由会员分享,可在线阅读,更多相关《ITU-T O 95-1988 PHASE AND AMPLITUDE HIT COUNTERS FOR TELEPHONE-TYPE CIRCUITS《相位和幅度击中柜台 电话型电路-规格为测量设备 第4研究组 共4页》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 / TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU30%#)&)#!4)/.3G0G0&/2G0G0-%!352).G0G0%15)0-%.40(!3%G0G0!.$G0G0!-0,)45$%G0G0()4G0G0#/5.4%23&/2G0G04%,%0(/.%G13490%G0G0#)2#5)43)45G134G0G0RecommendationG0G0/ (Extract from the “LUEG0“OOK)NOTES1 ITU-T Recommenda
2、tion O.95 was published in Fascicle IV.4 of the Blue Book. This file is an extract from theBlue Book. While the presentation and layout of the text might be slightly different from the Blue Book version, thecontents of the file are identical to the Blue Book version and copyright conditions remain u
3、nchanged (see below).2 In this Recommendation, the expression “Administration” is used for conciseness to indicate both atelecommunication administration and a recognized operating agency. ITU 1988, 1993All rights reserved. No part of this publication may be reproduced or utilized in any form or by
4、any means, electronic ormechanical, including photocopying and microfilm, without permission in writing from the ITU.Fascicle IV.4 - Rec. O.95 1Recommendation O.95Fascicle IV.4 - Rec. O.95PHASE AND AMPLITUDE HIT COUNTERS FOR TELEPHONE-TYPE CIRCUITS(Geneva, 1980)1 GeneralThis specification provides t
5、he outline requirements for an instrument to be used for counting phase andamplitude hits on telephone-type circuits. The instrument will independently count the number of phase hits and thenumber of amplitude hits that occur in a given period of time.Phase or amplitude hits are defined as sudden po
6、sitive or negative changes in phase or amplitude of anobserved test signal which exceed a specified threshold and persist for a period of time greater than a specified duration.The specifications given below for the transmitter and receiver input section shall correspond with 2.2 b) to2.2 d) and 2.3
7、 b) to 2.3 d) of Recommendation O.91 in order to facilitate the combination of this instrument with aphase jitter meter conforming to Recommendation O.91 in one set.2 Transmitter2.1 Test signal frequency.1020 10 Hz2.2 Send level . 30 dBm to 0 dBm2.3 Output impedance (frequency range 300 Hz to 4 kHz)
8、 Balanced, earth free (other impedances optional) 600 ohms Return loss 30 dB Output signal balance 40 dB2.4 Phase jitter at source 0.1 degree peak-to-peak (see Recommendation O.91)3 Receiver input section3.1 Sensitivity and frequency rangeThe receiver should be capable of measuring with input levels
9、 between 40 and + 10 dBm and frequenciesbetween 990 and 1030 Hz.3.2 SelectivityPower line hum protection high-pass filter with a nominal cutoff frequency of 400 Hz with at least 12 dB peroctave slope.If the filter is not located directly at the instrument input, hum voltages equal to or smaller than
10、 the test signalshall not result in measurement errors greater than those with the filter in front of the set.Protection for limiter against channel noise low-pass filter with a nominal cutoff frequency of 1800 Hz withat least 24 dB per octave slope.3.3 Input impedance (frequency range 300 Hz to 4 k
11、Hz) Balanced, earth free Input longitudinal interference loss 46 dB3.3.1 Terminating impedance (other impedances optional) 600 ohms Return loss 30 dB3.3.2 High impedance approx. 20 kohms Bridging loss across 300 ohms 0.15 dB2 Fascicle IV.4 - Rec. O.954 Phase hit detection characteristics4.1 Threshol
12、d settingsSettings from 5 to 45 in steps of 5 shall be provided with an accuracy of 0.5, 10% referred to theselected threshold1). Additional settings may be optionally provided.4.2 Guard intervalA guard interval shall be provided by electronic gating or other equivalent means to prevent the counter
13、fromregistering phase hits shorter than 4 ms. The guard interval shall be tested as follows:With a threshold setting of 20, phase hits shall be counted correctly if the test signal is changed in phase by25 for a duration of 5 ms or more. When the duration of the 25 phase changes is gradually reduced
14、 until the phase hitcounter stops counting, the corresponding duration of the phase changes of the test signal shall be 4 ms 10%.4.3 Hit rate of changeSlow phase changes shall not be counted. This characteristic shall be tested as follows:With a threshold setting of 20, a phase hit shall be counted
15、when the phase of a test signal is linearly varied by100 in a time interval of 20 ms or less. A phase hit shall not be counted when the phase of the test signal is linearlyvaried by 100 in a time interval of 50 ms or more. The same requirements shall be met with 100 changes of oppositepolarity.4.4 A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTO951988PHASEANDAMPLITUDEHITCOUNTERSFORTELEPHONETYPECIRCUITS 相位 幅度 击中 柜台 电话 电路 规格 测量 设备 研究 PDF

链接地址:http://www.mydoc123.com/p-800467.html