ITU-T O 71-1988 IMPULSIVE NOISE MEASURING EQUIPMENT FOR TELEPHONE-TYPE CIRCUITS《脉冲噪声测量设备 电话型电路-规格为测量设备的第4研究组 共4页 同时 作为Recmn H 13》.pdf
《ITU-T O 71-1988 IMPULSIVE NOISE MEASURING EQUIPMENT FOR TELEPHONE-TYPE CIRCUITS《脉冲噪声测量设备 电话型电路-规格为测量设备的第4研究组 共4页 同时 作为Recmn H 13》.pdf》由会员分享,可在线阅读,更多相关《ITU-T O 71-1988 IMPULSIVE NOISE MEASURING EQUIPMENT FOR TELEPHONE-TYPE CIRCUITS《脉冲噪声测量设备 电话型电路-规格为测量设备的第4研究组 共4页 同时 作为Recmn H 13》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 / TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU30%#) amended Geneva, 1976 and Melbourne, 1988)The requirements for the characteristics of an instrument capable of assessing the impulsive noise performanceof telephone-type circuits are described below and
2、must be adhered to in order to ensure compatibility of results obtainedby equipments standardized by the CCITT and produced by different manufacturers.1 Principle of operationThe instrument will record the number of times that the instantaneous voltage of the input signal exceeds apredetermined thre
3、shold during the period of measurement. The maximum rate at which the instrument can recordimpulses exceeding the threshold is 8 2 counts per second. The threshold level is calibrated in terms of the r.m.s.value of a sinusoidal input signal (dBm) whose peak value is just sufficient to cause the inst
4、rument to operate thecounting mechanism.2 Definition2.1 dead timeFor the purpose of this specification the dead time is defined as the time after which the counter is ready toregister another pulse following the start of the preceding pulse.3 Specification clauses3.1 Input impedance (frequency range
5、 300 Hz to 4 kHz) Balanced, earth free Input longitudinal interference loss . 46 dB3.1.1 Terminating impedance (other impedances optional). 600 ohms Return loss . 30 dB3.1.2 High impedance. approx. 20 kohms Bridging loss across 300 ohms . 0.15 dB3.2 Input balanceWith a pulse which is 60-dB higher th
6、an the threshold setting applied between the midpoint of the sourceimpedance and the earth terminal of the instrument the counter shall not operate.3.3 Operate level rangeThe minimum operate level range to which the instrument responds shall be from 0 to 50 dBm (i.e. 0 to 50 dB with respect to 1.1 V
7、, which is the peak voltage of a sine wave having a power of 1 mW in 600 ohms). Thethreshold shall be adjustable in 3 dB steps ( 0.5 dB) and the thresholds for positive and negative polarities of inputpulse shall not differ by more than 0.5 dB.3.4 Dead timeWhatever values of dead time are included i
8、n a particular instrument, a value of 125 25 ms shall beprovided in all cases._1)The text of this Recommendation has been established under the responsibility of Study Groups IV and XVII. Further elaborationof this Recommendation shall be the joint responsibility of these Study Groups.2 Fascicle IV.
9、4 - Rec. O.713.5 Attenuation/frequency characteristics3.5.1 Flat bandwidthResponse within the range 1 dB from 275 to 3250 Hz: 3 dB point 1 dB at 200 Hz; below 200 Hz, the attenuation shall rise at about 18 dB per octave; at 100 Hz, minimum attenuation17 dB; above 3250 Hz, the rise in attenuation sha
10、ll be compatible with the sensitivity requirement indicated in 3.7 below.3.5.2 Optional bandwidthsBy means of additional filters the equipment may provide other optional bandwidths.In any case it should be designed so that external filters can be added.One of the filters shall have the following cha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTO711988IMPULSIVENOISEMEASURINGEQUIPMENTFORTELEPHONETYPECIRCUITS 脉冲 噪声 测量 设备 电话 电路 规格 研究 同时 作为 RECMNH13PDF

链接地址:http://www.mydoc123.com/p-800446.html