ITU-T L 78-2008 Optical fibre cable construction for sewer duct applications (Study Group 6)《(预刊)安装在下水道管道的光缆》.pdf
《ITU-T L 78-2008 Optical fibre cable construction for sewer duct applications (Study Group 6)《(预刊)安装在下水道管道的光缆》.pdf》由会员分享,可在线阅读,更多相关《ITU-T L 78-2008 Optical fibre cable construction for sewer duct applications (Study Group 6)《(预刊)安装在下水道管道的光缆》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、 International Telecommunication Union ITU-T L.78TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/2008) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT Optical fibre cable construction for sewer duct applications Recommendation ITU-T L.78 Rec. ITU
2、-T L.78 (05/2008) i Recommendation ITU-T L.78 Optical fibre cable construction for sewer duct applications Summary Recommendation ITU-T L.78 describes the characteristics, construction and test methods for optical fibre cables to be installed in sewer ducts and drainpipes. The characteristics that a
3、 cable should have for an optical fibre to perform appropriately are described. Also, a method is described for determining whether or not the cable has the required characteristics. The required conditions may differ according to the installation environment; detailed test conditions need to be agr
4、eed upon between the user and manufacturer for the environment in which the cable is to be used. Source Recommendation ITU-T L.78 was approved on 29 May 2008 by ITU-T Study Group 6 (2005-2008) under Recommendation ITU-T A.8 procedure. ii Rec. ITU-T L.78 (05/2008) FOREWORD The International Telecommu
5、nication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff
6、 questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommend
7、ations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendat
8、ion, the expression “Administration“ is used for conciseness to indicate both a telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.g., interoperability
9、 or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that complian
10、ce with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTS ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or
11、 applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to
12、 implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2009 All rights reserved. No part of this publication may be reproduced, by
13、any means whatsoever, without the prior written permission of ITU. Rec. ITU-T L.78 (05/2008) iii CONTENTS Page 1 Scope 1 2 References. 1 3 Definitions 3 4 Abbreviations and acronyms 3 5 Characteristics of the optical fibres and cables. 3 5.1 Optical fibres 3 5.2 Mechanical characteristics 3 5.3 Envi
14、ronmental conditions. 4 5.4 Fire safety . 5 6 Cable construction 5 6.1 Fibre protection 5 6.2 Cable element . 5 6.3 Sheath . 6 6.4 Armour . 6 6.5 Water-blocking materials . 6 6.6 Cable identification 6 7 Test methods. 6 7.1 Test methods for cable elements 6 7.2 Test methods for mechanical characteri
15、stics of cable 7 7.3 Test methods for environmental characteristics. 8 7.4 Test methods for fire safety 9 Appendix I Chinese experience Construction of self-supporting optical fibre cables for sewer applications. 10 I.1 Cable design . 10 I.2 Fibre identification . 11 I.3 Mechanical performance of th
16、e cable. 11 I.4 Environmental characteristics of the cable. 12 Appendix II Italian experience Construction of optical fibre cables for sewer applications. 14 II.1 General design of the cable 14 II.2 Description of cable structure. 14 II.3 Main performance characteristics of the cable. 14 II.4 Other
17、characteristics of the cable . 15 iv Rec. ITU-T L.78 (05/2008) Introduction With the growth of fibre-to-the-home (FTTH) services, there is an increasing demand for ducts and tunnels in which to install optical fibre cables. However, in metropolitan areas it is difficult to increase the number of duc
18、ts and/or tunnels because of the cost and interference with traffic that it would involve. To install optical fibre cables in sewer ducts is one possible way to solve the duct shortage problem. However, the sewer pipe environment is different from that of ducts designed for telecommunication. Theref
19、ore, the required characteristics also differ from those for standard underground cables. This Recommendation is developed for this reason. Rec. ITU-T L.78 (05/2008) 1 Recommendation ITU-T L.78 Optical fibre cable construction for sewer duct applications 1 Scope This Recommendation: refers to optica
20、l fibre cables to be used for telecommunications networks in sewer ducts and/or drainpipes; deals with the mechanical and environmental characteristics of optical fibre cables for sewer applications. The optical fibre dimensional and transmission characteristics, together with their test methods, sh
21、ould comply with IEC 60793-2-10, ITU-T G.652, ITU-T G.653, ITU-T G.654, ITU-T G.655, ITU-T G.656 and ITU-T G.657, which deal with a multi-mode graded index optical fibre and single-mode optical fibres, respectively; deals with fundamental considerations related to optical fibre cable from mechanical
22、 and environmental standpoints; acknowledges that some optical fibre cables may contain metallic elements, for which reference should be made to b-ITU-T Plant (see ITU-T L.1), and other L-Series Recommendations; recommends that an optical fibre cable should be provided with cable end-sealing and pro
23、tection during cable delivery and storage, as used for metallic cables. If splicing components have been factory installed they should be adequately protected. 2 References The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute p
24、rovisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommend
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTL782008OPTICALFIBRECABLECONSTRUCTIONFORSEWERDUCTAPPLICATIONSSTUDYGROUP6 安装 在下 水道 管道 光缆 PDF

链接地址:http://www.mydoc123.com/p-799585.html