ITU-T L 76-2008 Copper loop requirements for various technologies including indoor and structured cabling (Study Group 6)《ITU-T推荐的L 76(ex L coloop) 包括室内和结构化布线的各种技术用铜线圈要求》.pdf
《ITU-T L 76-2008 Copper loop requirements for various technologies including indoor and structured cabling (Study Group 6)《ITU-T推荐的L 76(ex L coloop) 包括室内和结构化布线的各种技术用铜线圈要求》.pdf》由会员分享,可在线阅读,更多相关《ITU-T L 76-2008 Copper loop requirements for various technologies including indoor and structured cabling (Study Group 6)《ITU-T推荐的L 76(ex L coloop) 包括室内和结构化布线的各种技术用铜线圈要求》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、 International Telecommunication Union ITU-T L.76TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/2008) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT Copper loop requirements for various technologies including indoor and structured cabling Recom
2、mendation ITU-T L.76 Rec. ITU-T L.76 (05/2008) i Recommendation ITU-T L.76 Copper loop requirements for various technologies including indoor and structured cabling Summary Old indoor installations, designed for voice transmission, are responsible for intermittent faults and performance degradation,
3、 in terms of throughput, when they are used for broadband applications. Very often, the use of older cabling becomes impractical for todays needs. Structured cabling is a solution that allows reliable broadband transmission and accommodates the increasingly varied information and communication servi
4、ces, such as super-high speed internet, video-communication, voice over Internet protocol (VoIP), Video on Demand (VoD), Internet protocol television (IPTV), security, telemetry, etc. General customer premises and residential buildings cabling architectures are introduced. Pertinent electrical param
5、eters and requirements are referred to in ISO/IEC 11801 and ITU-T L.75. The purposes of Recommendation ITU-T L.76 are: to present general indoor network architectures; to recommend structured cabling as a solution for indoor network implementations; and to define the requirements to indoor copper ne
6、tworks. Source Recommendation ITU-T L.76 was approved on 29 May 2008 by ITU-T Study Group 6 (2005-2008) under Recommendation ITU-T A.8 procedure. Keywords General customer premises and residential buildings cabling, indoor copper cabling requirements, structured cabling. ii Rec. ITU-T L.76 (05/2008)
7、 FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for stu
8、dying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study gro
9、ups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with
10、ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate both a telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisi
11、ons (to ensure e.g. interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such
12、words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTS ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position
13、concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected
14、by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2009 All rights reserved. No part of thi
15、s publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. Rec. ITU-T L.76 (05/2008) iii CONTENTS Page 1 Scope 1 2 References. 1 3 Definitions 1 4 Abbreviations and acronyms 2 5 Conventions 3 6 Generic cabling system for customer premises 3 6.1 Structure o
16、f generic cabling for building telecommunication facilities . 3 6.2 Campus backbone cabling subsystem 3 6.3 Building backbone cabling subsystem . 3 6.4 Horizontal cabling subsystem. 3 6.5 Design objectives 4 7 Residential area telecommunication cabling 4 7.1 Principles 4 7.2 Multi-tenant unit/apartm
17、ent cabling system. 4 7.3 Single residential unit cabling system 5 8 Requirements 6 8.1 Performance of balanced cabling . 6 Bibliography. 8 Rec. ITU-T L.76 (05/2008) 1 Recommendation ITU-T L.76 Copper loop requirements for various technologies including indoor and structured cabling 1 Scope The purp
18、oses of this Recommendation are: to present general indoor network architectures; to recommend structured cabling as a solution for indoor network implementations; and to define the requirements for indoor copper networks. 2 References The following ITU-T Recommendations and other references contain
19、 provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the p
20、ossibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Rec
21、ommendation. ITU-T L.75 Recommendation ITU-T L.75 (2008), Test, acceptance and maintenance methods of copper subscriber pairs. ISO/IEC 11801 ISO/IEC 11801:2002, Information technology Generic cabling for customer premises. 3 Definitions This Recommendation defines the following terms (aligned with I
22、SO/IEC 11801): 3.1 balanced cable: Cable consisting of one or more metallic symmetrical cable elements (twisted pairs or quads). 3.2 building backbone cabling subsystem: Distribution system connecting the main distribution frame to an intermediate distribution frame, an intermediate distribution box
23、, a floor distribution frame or a floor distribution box in a building and the distribution system interconnecting intermediate distribution frames in a building. 3.3 building distribution frame (or box): Distribution frame (or box) installed in each multi-tenant unit for effective building wire man
24、agement in case of a configuration of a residential complex of more than two multi-tenant units. 3.4 cabling: System of telecommunication cables, cords and connecting hardware that can support the connection of information technology equipment. 3.5 campus: Premise containing one or more buildings. 3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTL762008COPPERLOOPREQUIREMENTSFORVARIOUSTECHNOLOGIESINCLUDINGINDOORANDSTRUCTUREDCABLINGSTUDYGROUP6ITUT

链接地址:http://www.mydoc123.com/p-799582.html