ITU-T K 20-2016 Resistibility of telecommunication equipment installed in a telecommunication centre to overvoltages and overcurrents (Study Group 5)《电信设备安装在电信中心要过电压过电流抵抗力(研究组5)》.pdf
《ITU-T K 20-2016 Resistibility of telecommunication equipment installed in a telecommunication centre to overvoltages and overcurrents (Study Group 5)《电信设备安装在电信中心要过电压过电流抵抗力(研究组5)》.pdf》由会员分享,可在线阅读,更多相关《ITU-T K 20-2016 Resistibility of telecommunication equipment installed in a telecommunication centre to overvoltages and overcurrents (Study Group 5)《电信设备安装在电信中心要过电压过电流抵抗力(研究组5)》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T K.20 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (06/2016) SERIES K: PROTECTION AGAINST INTERFERENCE Resistibility of telecommunication equipment installed in a telecommunication centre to overvoltages and overcurrents
2、Recommendation ITU-T K.20 Rec. ITU-T K.20 (06/2016) i Recommendation ITU-T K.20 Resistibility of telecommunication equipment installed in a telecommunication centre to overvoltages and overcurrents Summary Recommendation ITU-T K.20 specifies resistibility requirements and test procedures for telecom
3、munication equipment that is attached to or installed within a telecommunication centre. Overvoltages or overcurrents covered by this Recommendation include surges due to lightning on or near the line plant, short-term induction from adjacent a.c. power lines or railway systems, earth potential rise
4、 due to power faults, direct contact between telecommunication lines and power lines and electrostatic discharges. The sources for overvoltages in internal lines, between equipment/racks, are mainly inductive coupling caused by lightning currents being conducted in nearby lightning strokes or lightn
5、ing currents being conducted in nearby conductors. Major changes compared with the 2008 version of this Recommendation include: updated references; added information on which universal serial bus (USB) ports should be tested; added information on when to add protection to untested ports; added test
6、requirements for external coaxial cable ports; added test requirements for multiple conductor internal unshielded cable ports. Major changes compared with the 2011 version of this Recommendation include: added test requirements for unshielded twisted pair (UTP) Ethernet; added test requirements for
7、shielded twisted pair STP Ethernet; added test requirements for power over Ethernet (PoE); added STP shield testing. History Edition Recommendation Approval Study Group Unique ID* 1.0 ITU-T K.20 1984-10-19 11.1002/1000/6964 2.0 ITU-T K.20 1988-11-25 11.1002/1000/1387 3.0 ITU-T K.20 1991-03-18 V 11.1
8、002/1000/1388 4.0 ITU-T K.20 1993-03-12 V 11.1002/1000/1389 5.0 ITU-T K.20 1996-10-18 5 11.1002/1000/3880 6.0 ITU-T K.20 2000-02-25 5 11.1002/1000/4904 7.0 ITU-T K.20 2003-07-29 5 11.1002/1000/6492 7.1 ITU-T K.20 (2003) Amd. 1 2004-11-12 5 11.1002/1000/7499 8.0 ITU-T K.20 2008-04-13 5 11.1002/1000/9
9、400 9.0 ITU-T K.20 2011-11-13 5 11.1002/1000/11420 10.0 ITU-T K.20 2015-04-22 5 11.1002/1000/12403 11.0 ITU-T K.20 2016-06-29 5 11.1002/1000/12867 Keywords 1.2/50-8/20, 10/700, Ethernet, external ports, internal port, overvoltage, overcurrent, power over Ethernet (PoE), power contact, power inductio
10、n, resistibility, subscriber line integrated circuit, SLIC, surges, telecommunication equipment, telecommunication centres, transverse, universal serial bus, USB. * To access the Recommendation, type the URL http:/handle.itu.int/ in the address field of your web browser, followed by the Recommendati
11、ons unique ID. For example, http:/handle.itu.int/11.1002/1000/11830-en. ii Rec. ITU-T K.20 (06/2016) FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Teleco
12、mmunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardization As
13、sembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information technology w
14、hich fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate both a telecommunication administration and a recognized operating agency. Compliance with
15、 this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words “shall“ or some other obligatory l
16、anguage such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTSITU draws attention to the possibility that the practice or implementation of thi
17、s Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of the date
18、 of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult
19、the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2016 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. Rec. ITU-T K.20 (06/2016) iii Table of Contents Page 1 Scope . 1 2 References . 1 3 Definitions
20、1 3.1 Terms defined elsewhere 1 3.2 Terms defined in this Recommendation . 2 4 Abbreviations and acronyms 2 5 Conventions 2 6 Tests 2 Appendix I Floating transverse power induction and earth potential rise test for ports connected to external symmetric pair cables 25 I.1 Introduction 25 I.2 Discussi
21、on on the reason for the damages 25 I.3 Test set-up and test voltages . 26 Bibliography. 27 Rec. ITU-T K.20 (06/2016) 1 Recommendation ITU-T K.20 Resistibility of telecommunication equipment installed in a telecommunication centre to overvoltages and overcurrents 1 Scope This Recommendation specifie
22、s resistibility requirements and test procedures for equipment installed in a telecommunication centre where the earthing, bonding and cabling between equipment/racks is in accordance with ITU-T K.27. This Recommendation applies to both external and internal ports. ITU-T K.44 is an integral part of
23、this Recommendation and should be read in conjunction with ITU-T K.11, ITU-T K.39 and ITU-T K.46. This Recommendation applies to all telecommunication equipment, whether network operator or customer owned, including telephony, routers and modems, etc. It does not apply to personal computers and prin
24、ters, etc. 2 References The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTK202016RESISTIBILITYOFTELECOMMUNICATIONEQUIPMENTINSTALLEDINATELECOMMUNICATIONCENTRETOOVERVOLTAGESANDOVERCURRENTSSTUDYGROUP5

链接地址:http://www.mydoc123.com/p-799172.html