《ITU-T H 830 1-2017 Conformance of ITU-T H 810 personal health system Services interface Part 1 Web services interoperability Health & Fitness Service sender (Study Group 16).pdf》由会员分享,可在线阅读,更多相关《ITU-T H 830 1-2017 Conformance of ITU-T H 810 personal health system Services interface Part 1 Web services interoperability Health & Fitness Service sender (Study Group 16).pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T H.830.1 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (04/2017) SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS E-health multimedia services and applications Interoperability compliance testing of personal health systems (HR
2、N, PAN, LAN, TAN and WAN) Conformance of ITU-T H.810 personal health system: Services interface Part 1: Web services interoperability: Health Part 1: Web Services Interoperability. HFS Sender (Version 1.6, 2017-03-14), that was developed by the Personal Connected Health Alliance. A number of version
3、s of this specification existed before transposition. This Recommendation includes an electronic attachment with the protocol implementation conformance statements (PICS) and the protocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. History Edition
4、 Recommendation Approval Study Group Unique ID* 1.0 ITU-T H.831 2015-01-13 16 11.1002/1000/12249 1.0 ITU-T H.830.1 2015-01-13 16 11.1002/1000/12587 2.0 ITU-T H.830.1 2016-07-14 16 11.1002/1000/12921 3.0 ITU-T H.830.1 2017-04-13 16 11.1002/1000/13201 Keywords Conformance testing, Continua Design Guid
5、elines, e-health, Health Part 1: Web Services Interoperability. HFS Sender (Version 1.6, 2017-03-14), that was developed by the Personal Connected Health Alliance. The table below shows the revision history of this test specification; it may contain versions that existed before transposition. Versio
6、n Date Revision history 1.2 2012-10-05 Initial release for Test Tool DG2011. It is the same version as “TSS users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the
7、 currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation. ITU-T H.810 (2016) Recommendation ITU-T H.810 (2016), Interoperability design guidelines for personal hea
8、lth systems. ITU-T H.812 Recommendation ITU-T H.812 (2016), Interoperability design guidelines for personal health systems: Services interface: Common certified capability class. _ 1 This Recommendation includes an electronic attachment with the protocol implementation conformance statements (PICS)
9、and the protocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. 2 Rec. ITU-T H.830.1 (04/2017) ITU-T H.812.1 Recommendation ITU-T H.812.1 (2016), Interoperability design guidelines for personal health systems: Services interface: Observation upload c
10、ertified capability class. ITU-T H.812.2 Recommendation ITU-T H.812.2 (2016), Interoperability design guidelines for personal health systems: Services interface: Questionnaires certified capability class. ITU-T H.812.3 Recommendation ITU-T H.812.3 (2016), Interoperability design guidelines for perso
11、nal health systems: Services interface: Capability exchange certified capability class. ITU-T H.812.4 Recommendation ITU-T H.812.4 (2016), Interoperability design guidelines for personal health systems: Services interface: Authenticated persistent session certified capability class. OASIS/WS-I BP OA
12、SIS/WS-I (2006), Basic Profile Version 1.1. http:/www.ws-i.org/Profiles/BasicProfile-1.1.html OASIS/WS-I BSP OASIS/WS-I (2007), Basic Security Profile Version 1.0. http:/www.ws-i.org/Profiles/BasicSecurityProfile-1.0.html OASIS WS-I RM OASIS (2007), Web Services Reliable Messaging (WS-Reliable Messa
13、ging) Version 1.1. http:/docs.oasis-open.org/ws-rx/wsrm/200702/wsrm-1.1-spec-cs-01.pdf 3 Definitions 3.1 Terms defined elsewhere None. 3.2 Terms defined in this Recommendation None. 4 Abbreviations and acronyms This Recommendation uses the following abbreviations and acronyms: AHD Application Hostin
14、g Device ATS Abstract Test Suite ATNA Audit Trail and Node Authentication CDG Continua Design Guidelines CGM Continuous Glucose Monitor DUT Device Under Test EPR Endpoint Reference GUI Graphical User Interface HFS Health M BP-R9981; M BP-R1014; M BP-R1008; M BP-R1009; M BP-R1033; R BP-R1032; M Test
15、purpose Check that: An Envelope must conform to the structure specified in SOAP1.2 Section 5.1, “SOAP Envelope” AND an Envelope must have exactly zero or one child elements of the soap:Body element AND the children of the soap:body element in an Envelope must be namespace qualified AND An Envelope m
16、ust not contain a Document Type Declaration (DTD) or Processing Instructions AND an Envelope should not contain the namespace declaration xmlns:xml=”http/www.w3.org/XML/1998/namespace AND the soap:envelope, soap:header and soap:body elements must not have attributes in the namespace “http:/schemas.x
17、mlsoap.org/soap/envelope/” Applicability C_SEN_000 AND C_SEN_GEN_003 Other PICS Initial condition The simulated HFS receiver has a WebService enabled with many different services and the HFS sender under test has a SOAP message ready to be sent to the respective service according to its needs. Test
18、procedure 1. The HFS sender under test sends the SOAP message to the HFS receiver. 2. Check that the captured message has the following structure: . Here are the children of soap:Envelope where soap:Header is optional and it is recommended that the namespace is not http:/www.w3.org/XML/1998/namespac
19、e. Pass/Fail criteria Check that: The message has, in this order, an envelope, an optional header and a body. The namespaces that appear in the soap message are qualified. Soap:envelope, soap:header and soap:body do not have attributes in the namespace “http:/schemas.xmlsoap.org/soap/envelope/“. The
20、re is no DTD or processing instructions in the envelope. The SOAP envelopes namespace is “http:/www.w3.org/2003/05/soap-envelope“ to 10 Rec. ITU-T H.830.1 (04/2017) support SOAP 1.2 b-SOAP 1.2. Notes BP-R2201 and BP-R2210 imply that there may be at most one child element of the soap:Body. The refere
21、nced errata, NE05, would not be allowed by Continua (not compliant with the WS-I Profile). TP Id TP/HFS/SEN/WSI/BP/BV-001 TP label SOAP encodingStyle Attribute Coverage Spec OASIS/WS-I BP Testable items BP-R1005; M BP-R1006; M BP-R1007; M Test purpose Check that: An Envelope must not contain soap:en
22、codingStyle attributes on any of the elements whose namespace name is “http:/schemas.xmlsoap.org/soap/envelope/” AND an Envelope must not contain soap:encodingStyle attributes on any element that is a child of soap:body. AND an Envelope described in an rpc-literal binding must not contain soap:encod
23、ingStyle attribute on any element that is a grandchild of soap:Body Applicability C_SEN_000 AND C_SEN_GEN_003 Other PICS Initial condition The simulated HFS receiver has a WebService enabled with many different services and the HFS sender under test has a SOAP message ready to be sent to the respect
24、ive service according to its needs. Test procedure 1. Make the HFS sender under test send a SOAP message. 2. Check within the captured message: a. If the soap:encodingStyle attribute is present, that the envelope contains: a namespace which is not “http:/schemas.xmlsoap.org/soap/envelope/“ an elemen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTH83012017CONFORMANCEOFITUTH810PERSONALHEALTHSYSTEMSERVICESINTERFACEPART1WEBSERVICESINTEROPERABILITYHEALTHFITNESSSERVICESENDERSTUDYGROUP16PDF

链接地址:http://www.mydoc123.com/p-797911.html