ITU-R BT 1438-2000 Subjective Assessment of Stereoscopic Television Pictures《立体声电视图象的主观评定》.pdf
《ITU-R BT 1438-2000 Subjective Assessment of Stereoscopic Television Pictures《立体声电视图象的主观评定》.pdf》由会员分享,可在线阅读,更多相关《ITU-R BT 1438-2000 Subjective Assessment of Stereoscopic Television Pictures《立体声电视图象的主观评定》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 Rec. ITU-R BT.1438 1 RECOMMENDATION ITU-R BT.1438 SUBJECTIVE ASSESSMENT OF STEREOSCOPIC TELEVISION PICTURES (Question ITU-R 234/11) (2000) Rec. ITU-R BT.1438 The ITU Radiocommunication Assembly, considering a) that studies are in progress to develop stereoscopic television as a potential future bro
2、adcast service; b) that Recommendation ITU-R BT.1198 has been established for stereoscopic television based on R- and L-eye two channel signals; c) that subjective assessments are a vital element in the design and introduction of stereoscopic television systems; d) that shooting conditions, viewing
3、conditions and type of display may influence observer fatigue; e) that common assessment conditions appropriate for stereoscopic television systems should be established; these conditions should include evaluation methods, shooting conditions, viewing conditions, test materials to be used in the ass
4、essment and screening methods to ensure that observers have normal depth perception, recommends that the conditions described below should be used for the subjective assessment of stereoscopic television systems. 1 Assessment factors Assessment factors generally applied to monoscopic television pict
5、ures, such as resolution, colour rendition, motion portrayal, overall quality, sharpness, depth, etc., could be applied to stereoscopic television systems. In addition, there would be many factors peculiar to stereoscopic television systems. Some of them are listed below, and further studies are req
6、uired to identify others and to establish physical definitions. Depth resolution Spatial resolution in depth direction. Coarse resolution in depth direction may reduce picture quality in stereoscopic television. Depth motion A factor related to whether motion or movement along depth direction is rep
7、roduced smoothly. Puppet theatre effect This describes one type of distortion in reproduced 3-D images. Stereoscopic objects are sometimes perceived as unnaturally large or small. Cardboard effect This describes another type of distortion in reproduced 3-D images. The 3-D positions of stereoscopic o
8、bjects are perceived stereoscopically but they appear unnaturally thin. 2 Assessment methods The methods described in Recommendation ITU-R BT.500 could be applied for the evaluation of the general picture quality of stereoscopic systems as well as sharpness and depth (see Annex 2). When a reference
9、image is available, double-stimulus continuous quality-scale or double-stimulus impairment scale methods can be used. Examples include 2 Rec. ITU-R BT.1438 comparison of display systems, quality assessment of coding systems, and so on. When no reference is available, the categorical judgement method
10、 can be used, for example, to identify the merits of stereoscopic systems. Evaluation methods for the assessment of particular factors of stereoscopic television systems require further study. 3 Viewing conditions Two major factors peculiar to stereoscopic display should be taken into consideration,
11、 namely the display frame effect and inconsistency between accommodation and convergence. Stereoscopic pictures appear highly unnatural when objects positioned in front of the screen approach the screen frame. This unnatural effect is called “the frame effect”. The effect is generally reduced with a
12、 larger screen, because observers are less conscious of the existence of the frame when the screen is larger. The human eye focuses on an object according to the distance to that object. At the same time, we also control the convergence point (gaze point) on the object. Therefore, there is no incons
13、istency between accommodation and convergence in our everyday life. However when viewing stereoscopic images, the focus point (accommodation) must always be fixed on the screen, independent of the convergence point which is derived from the disparity of the signals. Otherwise, the observer cannot fo
14、cus clearly. Thus, an inconsistency between accommodation and convergence is introduced in stereoscopic systems. It is generally said that the minimum value for depth of field of the human eye is 0.3 D (Diopter: reciprocal value of distance (m) Hiruma and Fukuda, 1990. This means that we can perceiv
15、e the image without defocusing when the object is located within 0.3 D. When viewing stereoscopic television, the accommodation point is fixed on the screen, and therefore stereoscopic pictures should preferably be displayed within this range. Since ordinary television programmes include images at i
16、nfinite distance (that is D = 0), the desirable range of depth to be displayed with stereoscopic systems is considered to be within 0 to 0.6 D. Therefore, 0.3 D, i.e. 3.3 m, is considered to be the optimum viewing distance. Camera parameters (camera separation, camera convergence angle, focal length
17、 of lens), resolution of the system and the frame effect should be taken into account in determining viewing conditions (screen size). In the case of HDTV when watching at the standard viewing distance of 3 H (H denotes picture height), the viewing distance of 3.3 m corresponds to a 90-inch screen.
18、In the case of standard definition television (SDTV) when watching at the standard viewing distance of 6 H, this distance corresponds to a 36-inch screen. A subjective assessment of the relationship between screen size and depth perception was carried out with stereoscopic HDTV system, and the resul
19、ts showed that the most natural depth perception was obtained with a screen size of 120 inches, which corresponds to viewing distance of 2.2 H Yamanoue et al., 1997. 4 Observers Observers should have normal acuity (see Recommendation ITU-R BT.500). In addition, they should have normal stereopsis. In
20、 order to check their stereopsis, vision test materials listed in Annex 1 can be used. 5 Test materials Test materials for screening observers and still and motion sequences of natural scenes are listed in Annex. 1. The 3-D effects obtained from stereoscopic pictures depend largely on the shooting c
21、onditions, such as camera separation, camera convergence angle and focal length of the lens. The motion sequences were shot under the condition of camera separation of 65 mm, corresponding to average eye separation, and most of them were produced with the uncrossed camera layout, which gives an orth
22、ostereoscopic condition Yamanoue et al., 1998. Rec. ITU-R BT.1438 3 REFERENCES HIRUMA, N. and FUKUDA, T. December, 1990 Accommodation response to binocular stereoscopic TV images and their viewing conditions. J. SMPTE, 102, 12, p. 2047-2054. YAMANOUE, H. et al. October, 1997 Subjective study on the
23、orthostereoscopic conditions for 3D-HDTV. ITE Tech. Report, Vol. 21, 63, p. 7-12. YAMANOUE, H. et al. 1998 Orthostereoscopic conditions for 3-D HDTV. Proc. SPIE, 3295, Stereoscopic displays and Applications IV. ANNEX 1 Test materials for subjective assessment of stereoscopic television pictures 1 Vi
24、sion test Table 2 lists the test charts for the vision test. These 12 tests are selected according to the hierarchy of the human visual system from lower to higher levels. Eight main vision tests (VTs) are described below, and the other four are for the clinical test. Observers must have normal ster
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITURBT14382000SUBJECTIVEASSESSMENTOFSTEREOSCOPICTELEVISIONPICTURES 立体声 电视 图象 主观 评定 PDF

链接地址:http://www.mydoc123.com/p-790595.html