INTERN CEMS GT-7F-2009 South Florida Exposure Test For Paint《南佛罗里达油漆曝晒试验》.pdf
《INTERN CEMS GT-7F-2009 South Florida Exposure Test For Paint《南佛罗里达油漆曝晒试验》.pdf》由会员分享,可在线阅读,更多相关《INTERN CEMS GT-7F-2009 South Florida Exposure Test For Paint《南佛罗里达油漆曝晒试验》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2009 by Navistar, Inc. AUGUST 2009 Page 1 of 3 NAVISTAR, INC. CEMS (CORPORATE ENGINEERING MATERIAL SPECIF
2、ICATION) NUMBER: CEMS GT-7F TITLE: South Florida Exposure Test For Paint CURRENT ISSUE DATE: August 2009 WRITTEN/REVIEWED BY: Materials Engineering APPROVED BY: Materials Engineering SUPERSEDES ISSUE OF: August 2001 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION This specifica
3、tion may involve hazardous materials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regulatory limits prior t
4、o use. Change Notice: Replaced “International Truck and Engine Corporation” with “Navistar, Inc.” per corporate directive. 1.0 SCOPE This is a method for evaluating the ability of a dry film of paint to withstand degradation upon prolonged exposure in a South Florida environment. 2.0 APPARATUS 2.1 E
5、xposure racks positioned in a suitable South Florida location 2.2 60 degree glossmeter, Gardner or equivalent 3.0 MATERIAL 3.1 Bonderite CD-10 or Bonderite 958 zinc phosphated steel panels, 100 x 300 mm (4 x 12 inches), available from Advanced Coatings Technologies, 273 Industrial Drive, Hillsdale,
6、Michigan 49242. OR 3.2 Fiber glass reinforced plastic panels available from Materials Engineering, Navistar, Inc., P. O. Box 1109, Fort Wayne, Indiana 46801-1109. 3.3 Mild detergent 3.4 Cleaner-waxer compound, DuPont No. 7 or equivalent 3.5 Absorbent paper, Kleenex, Kimwipes or equivalent 4.0 PROCED
7、URE 4.1 Prepare the appropriate quantity and type of panels for the grade of paint being tested according to the procedure specified in Test Method GT-13, Panel Preparation. 4.1.1 Three steel panels - Grades -17, -17HS, -18, -19, -19HS, -29, -29HS, -29T, -29THS, -32, 32HS, -32HS/Ur, -33, -41, -43, -
8、43W, -50, -54, -55, -55W, -61, and -62 4.1.2 Six steel panels - Grades -53 and -53A 4.1.3 Three fiber glass reinforced plastic panels - Grades -52 and -52HS 4.1.4 For grades where six panels are prepared, two alternative drying procedures, an air dry and an oven dry, are specified. For these grades,
9、 three panels will be dried according to the air drying procedure and the remaining three panels will be dried according to the oven drying procedure. For grades where three panels are prepared, only one drying procedure is specified; for these grades, the three panels will be dried according to thi
10、s procedure. Copyright Navistar International Corporation Provided by IHS under license with INTERNNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NUMBER: CEMS GT-7F TITLE: South Florida Exposure Test For Paint CURRENT ISSUE DATE: August 2009 This document is restr
11、icted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2009 by Navistar, Inc. AUGUST 2009 Page 2 of 3 4.2 For Grades -50, -52, -52W, -52HS, -53, -53A, -55, and -55W, prepare, in addi
12、tion to the panels required in Step (1), the following quantity and type of panel for the grade of primer being tested. Again, prepare these panels according to the procedure specified under Panel Preparation, for the applicable grade; however, on these panels, proceed only to but not including the
13、step in which the primed and dried panels are sanded. 4.2.1 Three steel panels - Grades -50, -55, and -55W 4.2.2 Six steel panels - Grades -53 and -53A 4.2.3 Three fiber glass reinforced plastic panels - Grades -52 and -52HS 4.2.4 For Grades -53 and -53A, where six panels are prepared, three panels
14、will be dried according to the air drying procedure specified and remaining three panels according to the oven drying procedure specified. To prevent rusting, cover the remaining unpainted surfaces on each of the panels with a protective coating such as a primer or lacquer. 4.3 Age the prepared pane
15、ls for 72 hours at 49 + 3C (120 + 5F). 4.4Position the panels in South Florida at a 5 angle facing south and expose for the time period specified in the appropriate grade sheet from CEMS G-5, For Grades -50, -52, -52HS, -53, -53A, -55, and -55W, panels with primer and enamel top coat from Step (1) o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- INTERNCEMSGT7F2009SOUTHFLORIDAEXPOSURETESTFORPAINT 佛罗里达 油漆 曝晒 试验 PDF

链接地址:http://www.mydoc123.com/p-785956.html