INTERN CEMS BT-10-2009 Oxidation Corrosion Test《氧化腐蚀试验》.pdf
《INTERN CEMS BT-10-2009 Oxidation Corrosion Test《氧化腐蚀试验》.pdf》由会员分享,可在线阅读,更多相关《INTERN CEMS BT-10-2009 Oxidation Corrosion Test《氧化腐蚀试验》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2009 Navistar, Inc. AUGUST 2009 Page 1 of 6 NAVISTAR, INC. CEMS (CORPORATE ENGINEERING MATERIAL SPECIFIC
2、ATION) NUMBER: CEMS BT-10 TITLE: Oxidation Corrosion Test CURRENT ISSUE DATE: August 2009 WRITTEN/REVIEWED BY: Materials Engineering APPROVED BY: Materials Engineering SUPERSEDES ISSUE OF: October 2001 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION This specification may invol
3、ve hazardous materials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regulatory limits prior to use. Change
4、Notice: Replaced “International Truck and Engine Corporation” with “Navistar, Inc.” per corporate directive. 1.0 SCOPE This is a method for determining oxidation stability of fluids and their corrosive attack on metals. 2.0 APPARATUS 2.1 Test cell - Pyrex glass test tube, 38 x 300 millimeters, with
5、a 34/45 standard taper ground glass joint 2.2 Condenser - Allihn type, Pyrex glass, 300 millimeter jacket and a 34/45 standard taper ground glass joint to fit the test cell. 2.3 Air tube - Pyrex (see Figures 1 and 3, pages 3 and 5, respectively) 2.4 Ring rod - (see Figure 2, page 4) 2.5 Bath capable
6、 of maintaining a test temperature 2F (1C) 2.6 Analytical balance with a sensitivity of 0.1 milligram 2.7 Nylon or stainless steel forceps 2.8 Flowmeter capable of measuring 50 5 milliliters per minute of clean dry air 2.9 Four ounce (120 ml) bottle 3.0 MATERIAL The metal corrosion specimens will be
7、 as shown in Figure 4, page 5, and will meet the following specifications: 3.1 Aluminum, cold rolled sheet: 2024-0 per ASTM B 209 (AA2024-0 per SAE J457) 3.2 Copper, cold rolled annealed sheet: Alloy 110 per ASTM B 152 (CA110 per SAE J463), or Type 110 per CEMS C-3 3.3 Steel, SAE 1010 cold rolled sh
8、eet 3.4 Cartridge brass, annealed: Alloy 260 per ASTM B 36 (CA260 per SAE J463), or Type 260 per CEMS C-3. 3.5 Test fluid Other required test fluids/materials are: 3.5.1 Mild wetting agent, Alconox or equivalent: 3.5.2 Potassium cyanide, reagent grade: 3.5.3 Toluene, reagent grade 3.5.4 Alundum, 90
9、mesh, RR Crystalline, Blue Label 3.5.5 Isopropyl alcohol, reagent grade 3.5.6 Trichloroethylene, technical grade Copyright Navistar International Corporation Provided by IHS under license with INTERNNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NUMBER: CEMS BT-10
10、 TITLE Oxidation Corrosion Test CURRENT ISSUE DATE: August 2009 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2009 Navistar, Inc. AUGUST 2009 Page 2 of
11、 6 3.5.7 Cleansing tissue, Kleenex or equivalent 3.5.8 Acetone, reagent grade 3.5.9 No. 212 Eberhard Faber Eraser or equivalent 3.5.10 Cotton, clean 3.5.11 Rubber or plastic gloves 4.0 PROCEDURE 4.1 Prepare the metal specimens as follows: Clean the metal specimens by washing with hot toluene followe
12、d by rinsing with isopropyl alcohol. Rub the surface with cotton dipped in toluene and alundum using enough pressure to remove all surface imperfections. The edges of the specimens and hole should also be polished. Rewash the specimens as before and wipe with a cleansing tissue. For the final rinse
13、wash with alcohol, handling the specimens with stainless steel or nylon forceps, and allow to dry on glass or stainless steel hooks. CAUTION: Do not use the same alundum for cleaning different metals as this may transfer metal. 4.2 Assemble ring rod on the air tube. Weigh each specimen to 0.1 millig
14、ram and place on the ring rod ready for immediate use. Record as Weight No. 1. 4.3 Place test specimens, ring rod and air tube assembly into the test cell. Add sufficient test fluid to cover specimens. The height of the test fluid should be 0.25 to 0.50 inch (6 to 12 mm) above the specimens. Install
15、 the condenser and then place the assembly in the bath maintained at the specified temperature such that the assembly is immersed above the level of the fluid in the test cell. Start clean, dry air through the cell and adjust the flow rate to 50 + 5 milliliters per minute. Start flow of cooling wate
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- INTERNCEMSBT102009OXIDATIONCORROSIONTEST 氧化 腐蚀 试验 PDF

链接地址:http://www.mydoc123.com/p-785815.html