1、 WORLDWIDE ENGINEERING STANDARDS Test Procedure GMW3043 Defogging System Maximum Performance Validation of Windshield, Side Windows and Backlight Copyright 2012 General Motors Company All Rights Reserved December 2012 Originating Department: North American Engineering Standards Page 1 of 10 1 Scope
2、Note: Nothing in this standard supercedes applicable laws and regulations. Note: In the event of conflict between the English and domestic language, the English language shall take precedence. 1.1 Purpose. The purpose of this standard is the validation of the performance capability of a defogging sy
3、stem for the windshield, side windows, and the performance of the electrically heated backlight. 1.2 Foreword. Not applicable. 1.3 Applicability. The applicability for this standard is for all passenger vehicle defroster systems and electrically heated backlights. 2 References Note: Only the latest
4、approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. None 2.2 GM Standards/Specifications. GMW15845 2.3 Additional References. None 3 Resources 3.1 Facilities. Climatic wind tunnel including a chassis dynamometer with adjusting possibilities for a dyna
5、mometer speed of 40 km/h minimum, a wind speed of 40 km/h minimum and an ambient temperature of -20 C minimum. 3.2 Equipment. 3.2.1 Temperature measuring and recording equipment for at least 13 measuring points. 3.2.2 Voltage and current measuring and recording equipment for compartment blower(s) an
6、d battery(ies). 3.2.3 Measuring and recording equipment for the engine speed. 3.2.4 Engine Oil, Coolant and Fuel. As released for the engine application at the test ambient temperature. 3.2.5 Device for operation and adjustment of accelerator pedal to accelerate and maintain vehicle speed. 3.2.6 Vap
7、or generator with water capacity adequate for generating 70 5 g/h water vapor per occupant seating position for 40 minutes. 3.2.7 Beaker for measuring the quantity of water required. 3.2.8 Timing device with stopwatch functions. 3.2.9 Means of recording cleared glass area for all tests (felt-tip mar
8、ker, camera, etc.) 3.2.10 Degrease using Methyl alcohol or equivalent degreasing agent. 3.2.11 Clean the window(s) with a cleaning agent of 3 to 5% ammonia or equivalent. 3.3 Test Vehicle/Test Piece. Test passenger vehicle with defroster systems and electrically heated backlights. Copyright General
9、Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW3043 Copyright 2012 General Motors Company All Rights Reserved December 2012 Page 2 of 10 3.4 Test Time. Ca
10、lendar time: 1 days Test hours: 9 hours Coordination hours: 10 hours 3.5 Test Required Information. Blower setting, HVAC mode selection and time of mode change are to be recorded. 3.5.1 Blower setting and HVAC mode settings are per the appropriate program Vehicle Technical Specification (VTS). 3.5.2
11、 The vision areas of the windscreen are specified per Appendix B. The same vision area is used on benchmarking tests. 3.6 Personnel/Skills. Provide one climate tunnel operator, one driver and at least one in-vehicle observer. 4 Procedure 4.1 Preparation. The vehicle shall be prepared for the climati
12、c tunnel and shall be equipped with devices according to 3.2. 4.1.1 Cleaning of the Windows. The inner surfaces of all vehicle glass (including backlight) shall be completely degreased with methyl alcohol or an equivalent degreasing agent. After drying, an ammonia solution of 3 to 5% shall be applie
13、d. The surface treated in this manner shall be allowed to dry and then wiped with a dry cotton cloth. 4.1.2 Settings. Initially the vehicle ventilation system controls shall be set to full hot, Production Outside-Air (P/OSA) and defrost and high blower. 4.1.2.1 The blower setting and mode change dur
14、ing the test is specified by the corresponding Vehicle Technical Specification (VTS). Default setting shall be used for benchmarking tests. The default mode change is to change to defog mode, with blower speed a customer selectable value best approximating 50% of the high blower airflow volume (appr
15、oximately 6 V in a 12 V blower system) (See Table 2). 4.1.2.2 The center face outlets shall remain closed and the outboard face vents shall be aimed as much as possible at the center of the mirror patch on the front side windows. This setup is performed regardless of the vehicle having dedicated Sid
16、e Window Defogger (SWD) outlets. 4.2 Conditions. 4.2.1 Environmental Conditions. Ambient temperature: -20 1 C. 4.2.2 Test Conditions. Deviations from the requirements of this standard shall have been agreed upon. Such requirements shall be specified on component drawings, test certificates, reports,
17、 etc. 4.2.2.1 Soak. Allow vehicle to cool down with hood open. It shall be ensured that the entire vehicle is at a uniform temperature (vehicle mass, e.g., seat rail) of (-20 1C) prior to start of test. 4.2.2.2 Defogging Conditions. Vehicle and wind speeds as specified in the measurement program (se
18、e Table 2). 4.2.2.3 Electrical Power Supply. All electrical systems are supplied by the internal vehicle power supply. Headlights (low beam), backlight defogging system and heated seats (if standard equipment) are switched on (heated seats to maximum performance). If a time out occurs on either the
19、backlight defogging system or heated seats, they are to be turned back on for the duration of the test. 4.2.2.4 Dynamometer Load. Dynamometer loading is to be set to road load at a vehicle mass of curb weight plus the driver. The acceleration and deceleration rate is shown in Table 2. 4.2.2.5 Gear S
20、tep or Drive Position (See Table 1). Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW3043 Copyright 2012 General Motors Company All Right
21、s Reserved December 2012 Page 3 of 10 Table 1: Gear Steps or Drive Positions Transmission Speed: 40 km/h Manual Transmission 4 Speed, 5 Speed, or 6 Speed 3rd Gear Automatic Transmission Drive 4.2.2.5.1 The specified dynamometer speeds are driven at road load (on level stretches without acceleration)
22、. 4.2.2.5.2 For repeat measurements on vehicles with automatic transmissions, it shall be ensured that same dynamometer speeds are driven at the same lowest engine speeds. 4.3 Instructions. 4.3.1 Measuring Program. Table 2: Measuring Program Temperature HVAC Vehicle Speed Wind Speed Duration 1 Soak
23、-20 C Blower Off 0 km/h 15 km/h Until Seat Rail at -20 1 C 2 Fog -20 C Blower Off 0 km/h 5 km/h 10 minutes 3 Test -20 C Full Hot Temperature, Defrost Mode, Maximum Blower Speed 40 km/h Note 1 40 km/h From Engine Crank (t = 0) Until drivers Critical Area is Cleared (t = Switch) 4 Test -20 C Temperatu
24、re Control to Maintain Breath Level Temperature Between 23 C and 25 C, Mode per VTS (Default Defog Mode, 6 V HVAC Blower) 40 km/h 40 km/h Switch t 50 minutes Note 1: Vehicle acceleration to be at 3.0 km/h/s, deceleration at 4.0 km/h/s. Accelerate vehicle at 3.0 km/h/s until vehicle speed target is r
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW30432012DEFOGGINGSYSTEMMAXIMUMPERFORMANCEVALIDATIONOFWINDSHIELDSIDEWINDOWSANDBACKLIGHTISSUE4ENGLISHPDF

链接地址:http://www.mydoc123.com/p-757993.html