GMW GMW16619-2011 Headlamp Washer Systems High Pressure Pump Issue 1 English《前照灯洗涤器系统的高压泵 第1次出版(英文版本)》.pdf
《GMW GMW16619-2011 Headlamp Washer Systems High Pressure Pump Issue 1 English《前照灯洗涤器系统的高压泵 第1次出版(英文版本)》.pdf》由会员分享,可在线阅读,更多相关《GMW GMW16619-2011 Headlamp Washer Systems High Pressure Pump Issue 1 English《前照灯洗涤器系统的高压泵 第1次出版(英文版本)》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、 WORLDWIDE ENGINEERING STANDARDS Test Procedure GMW16619 Headlamp Washer Systems High Pressure Pump Copyright 2011 General Motors Company All Rights Reserved November 2011 Originating Department: North American Engineering Standards Page 1 of 13 1 Scope Note: Nothing in this standard supercedes appl
2、icable laws and regulations. Note: In the event of conflict between the English and domestic language, the English language shall take precedence. 1.1 Purpose. This specification stipulates the requirements, the general test conditions and the test methods for operational, material tests, and the du
3、rability test for high pressure pumps for headlamp washer systems, referred to as the pump. In addition to the requirements of this specification, the pump shall fulfill the lawful requirements of the countries in which it is used when assembled to a high pressure headlamp washer system. 1.2 Forewor
4、d. Not applicable. 1.3 Applicability. Not applicable. 2 References Note: Only the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. DIN 500 EN 10204 SMS 2983 E DIN 400509 ISO 1431-1 VDA 260 ECE R45 SAE 30201 2.2 GM Standards/Specifications. G
5、ME 14090 GMW3097 GMW3191 GMW3059 GMW3103 GMW3286 GMW3091 GMW3172 GMW14729 2.3 Additional References. Japanese Industrial Standard D5704 1970 3 Resources 3.1 Facilities. 3.1.1 Calibration. The test facilities and equipment shall be in good working order and shall have a valid calibration label. 3.1.2
6、 Alternatives. Alternative test facilities and equipment may also be used. However, all measuring variables as specified in this specification shall be determined correctly with respect to its physical definition. As required by the indicated test methods, test specifications and DIN standards, etc.
7、 Temperature Cabinet. Recirculating air temperature cabinet with air extraction system, explosion proof. Test Space: Suitable chambers: Two passages, diameter 50 mm Temperature range: -40 C+ 120 C, continuously adjustable Permissible temperature deviation: 3 C Temperature constancy: 3 C spatially an
8、d temporally Rate of acceleration of temperature for the empty tempering chamber: 1 C/minute (recommended value) Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE E
9、NGINEERING STANDARDS GMW16619 Copyright 2011 General Motors Company All Rights Reserved November 2011 Page 2 of 13 3.2 Equipment. 3.2.1 Electromagnetic oscillation table with control unit for oscillation test. 3.2.2 Durability Test Equipment. Suitable test equipment for procedure of durability test
10、consists of a counter and time switch. The durability test equipment is a device used to operate the pump for the total number of durability test cycles according to preset operating and break times. Upon completion of the specified number of cycles, the durability test equipment shall shut off auto
11、matically. 3.2.2.1 As required by the indicated test methods and specifications. 3.2.2.2 Devices for attachment and mounting of the pumps to be tested. 3.2.2.3 Voltage Stabilizer. Range of voltage: 0 V thru 15 V continuously adjustable Range of current: 0 A thru 100 A, current limiting continuously
12、adjustable 3.2.2.4 Voltmeter for measuring range 0 V thru 20 V direct current voltage, class of accuracy 0.5 or better with corresponding compensating resistance. 3.2.2.5 Ammeter for measuring range 0 A thru 20 A direct current, class of accuracy 0.5 or better with corresponding shunt. 3.2.2.6 Digit
13、al displayed overpressure measuring instrument with analog output (printer and recorder output), limiting value stressable, instrument range 0 kPa thru 400 kPa, resolution 2 kPa minimum. 3.2.2.7 Time Switch with Counter. The time switch with counter is a device used to operate the pump for the total
14、 number of cycles according to preset operating and break times. Upon completion of the specified number of cycles, the time switch and counter unit shall automatically shut off. Time Switch attributes are located in Table 1. Table 1: Time Switch Requirements Attribute Value Input and output voltage
15、 0 V thru 15 V Rise time of output voltage 0.1 s Decay time of output voltage 0.1 s Intervals variable: continuously 1 s thru 30 s Break intervals variable continuously 1 s thru 30 s Reading accuracy 0.5 s Counter frequency 0.1 Hz, range: 2000 pulses 3.2.2.8 Over Pressure Measuring Instrument. Over
16、pressure measuring instrument for example, sensitive pressure gauge, grade 0.6, with an indicating range of 0 kPa thru 400 kPa and a scale division of 2 kPa. Electro dynamically working data receiver and electric indicating instruments that can be inserted. 3.2.2.9 Wire. 3.2.2.9.1 Wire having an app
17、ropriate length consisting of a twisted twin core wire (composed of twin, snaked, electric leads) with a cross section of 1.5 mm2 to connect the time switch, respectively durability test equipment with the pumps. The connecting elements, (e.g., cable shoes, pin plugs) on the ends of the wires shall
18、be faultless connected with the wires. The combining elements at the ends of the electric leads must be soldered with the electric leads. 3.2.2.9.2 Wire having an appropriate length consisting of a single wire with a cross section of 16 mm2 to connect the time switch, respectively durability test eq
19、uipment with the voltage stabilizer. The connecting elements, (e.g., cable shoes, pin plugs) on the ends of the wires shall be faultless connected with the wires. The combining elements at the ends of the electric lead must be soldered with the electric lead. This cable is necessary only at the endu
20、rance test of the pumps. Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW16619 Copyright 2011 General Motors Company All Rights Reserved
21、November 2011 Page 3 of 13 3.2.2.10 Oscillating Table with Oscillator. The oscillating table with oscillator, called shortly oscillating table, is a device with which oscillations are executed respectively in a vertical direction and two horizontal directions standing vertically one after another, t
22、emporally independent of each other. The oscillator must be so designed that the oscillating table executes oscillations corresponding to this data: Frequency: 10 Hz to 50 Hz sine, continuously adjustable, accuracy of reading 0.5 Hz Frequency drift: 60 s/octave 30 s/octave Oscillating amplitude: 0.2
23、 mm thru 0.7 mm adjustable, Accuracy of reading: 0.02 mm 3.2.2.11 Test Medium. As described, water (tap water) or a mixture of 50% by volume water and 50% by volume isopropanol is used. The amount of the test medium shall assure that the pump is filled with water throughout the test. 3.2.2.12 Test N
24、ozzle. A test nozzle is required for the function test according to 4.7.3 and 4.7.4. The nozzle shall allow reproducible measurements of the pump parameters. The nozzle dimensions are stated in Figure 1. For the durability test the production nozzles may be used. Figure 1: Test Nozzle, Material: Sta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW166192011HEADLAMPWASHERSYSTEMSHIGHPRESSUREPUMPISSUE1ENGLISH 前照灯 洗涤器 系统 高压泵 出版 英文 版本 PDF

链接地址:http://www.mydoc123.com/p-757814.html