GMW GMW15754-2013 A C Service Table Data Collection Procedure Issue 2 English.pdf
《GMW GMW15754-2013 A C Service Table Data Collection Procedure Issue 2 English.pdf》由会员分享,可在线阅读,更多相关《GMW GMW15754-2013 A C Service Table Data Collection Procedure Issue 2 English.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 WORLDWIDE ENGINEERING STANDARDS Test Procedure GMW15754 A/C Service Table Data Collection Procedure Copyright 2013 General Motors Company All Rights Reserved August 2013 Page 1 of 6 1 Scope Note: Nothing in this standard supercedes applicable laws and regulations. Note: In the event of conflict bet
2、ween the English and domestic language, the English language shall take precedence. 1.1 Purpose. To develop air conditioning (A/C) diagnostic table for service manual and service technician usage. 1.2 Foreword. Not applicable. 1.3 Applicability. For all vehicles with vapor compression refrigerant sy
3、stems. 2 References Note: Only the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. None 2.2 GM Standards/Specifications. GMW15845 2.3 Additional References. CG2310, Data Sheet A1 - GMW15754 Service Table Data Collection Spreadsheet 3 Resour
4、ces 3.1 Facilities. An ambient chamber is required that is large enough to fit the test vehicle. Ambient capability required from 15 C to 50 C at 10% to 80% relative humidity (RH). 3.1.1 Calibration. The test facilities and equipment shall be in good working order and shall have a valid calibration
5、label. 3.1.2 Alternatives. Alternative test facilities and equipment may also be used. However, all measuring variables as specified in this standard shall be determined correctly with respect to their physical definition. 3.2 Equipment. GMW15845 defines specific requirements of all test instrumenta
6、tion. 3.2.1 Temperature measuring devices to record front grille temperature, front left center instrument panel (I/P) outlet and left second row seat panel outlet (if there is a rear HVAC system). 3.2.2 Pressure measuring devices for test vehicle refrigeration system service ports (one high pressur
7、e and one low pressure). The following pressure transducer would be for a typical R134a refrigerant system; high pressure device capable of 0 kPa to 3500 kPa 50 kPa and low pressure device capable of 0 kPa to 500 kPa 0 kPa. 3.2.3 Battery charger to maintain vehicle battery during test. 3.2.4 Voltage
8、 measurement device to record test vehicle battery voltage. 3.2.5 Fan speed measurement device to record vehicle engine cooling fan speed for vehicles equipped with a mechanical engine cooling fan. 3.2.6 Voltage measurement(s) for each fan motor if vehicle is equipped with electric engine cooling fa
9、n(s) (identify if pusher/puller/left/right). 3.3 Test Vehicle/Test Piece. Passenger vehicles equipped with an A/C and heater system. Vehicle configurations (diesel, turbo, single fan, dual fan, auxiliary HVAC, heavy duty, shutters, baffles, compressor Copyright General Motors Company Provided by IHS
10、 under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW15754 Copyright 2013 General Motors Company All Rights Reserved August 2013 Page 2 of 6 drive ratio, etc.) and drive system operating mod
11、es are required for each unique idle service data set required for the service manual as determined by the Product Development Team (PDT). 3.4 Test Time. Calendar time: 1 to 2 days Test hours: 8 to 10 hours Coordination hours: 3 to 5 hours 3.5 Test Required Information. Not applicable. 3.6 Personnel
12、/Skills. One chamber operator. 4 Procedure 4.1 Preparation. Each vehicle shall be prepared for the climatic chamber testing with instrumentation described in 3.2. Vehicle shall have a full tank of gas and fully charged battery. Vehicles equipped with a refrigerant chiller require a method to power t
13、he chiller coolant pump on during this test. 4.2 Conditions. 4.2.1 Environmental Conditions. 4.2.1.1 Ambient. The temperature and humidity should be run as described in Table 1. Record the actual temperature and humidity at the test conditions from the facility instrumentation in the file CG2310 as
14、shown on Data Sheet A1. 4.2.2 Test Conditions. Deviations from the requirements of this standard shall have been agreed upon. Such requirements shall be specified on component drawings, test certificates, reports, etc. 4.2.2.1 The ambient temperature should be maintained to 1 C of the desired temper
15、ature. See Table 1. 4.2.2.2 The relative humidity should be maintained to 3% of the desired humidity. See Table 1. Table 1: Ambient Test Points Test Point Temperature (Degrees C) Relative Humidity % 1 15.0 60.0 2 22.0 20.0 3 22.0 60.0 4 27.0 20.0 5 27.0 40.0 6 27.0 60.0 7 32.0 20.0 8 32.0 40.0 9 32.
16、0 60.0 10 38.0 10.0 11 38.0 30.0 12 38.0 60.0 13 43.0 10.0 14 43.0 30.0 15 49.0 15.0 16 32.0 40.0 Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STAN
17、DARDS GMW15754 Copyright 2013 General Motors Company All Rights Reserved August 2013 Page 3 of 6 4.3 Instructions. 4.3.1 Chamber fluorescent lighting is to be used. No solar load (simulate service garage conditions). 4.3.2 Set test vehicle front and rear (when equipped) HVAC control head temperature
18、 control to Full Cold (for manual control systems) or 16 C (60 F) (for automatic climate control). 4.3.3 Set test vehicle front and rear (when equipped) HVAC control head blower speed to high position (14 V). 4.3.4 Set test vehicle HVAC control head air inlet to recirculation position. 4.3.5 Set tes
19、t vehicle transmission or drive unit in Park. Run test with engine running (including Electric Range Extending Vehicle (EREV) configuration) at idle condition. 4.3.6 Limit airflow as much as the test facility is capable (nozzle fully retracted) and use a 1.2 m (4 ft) high x 2.4 m (8 ft) wide idle bo
20、ard positioned 1.8 m (6 ft) in front of test vehicle (to block any residual airflow and best simulate service garage environment). 4.3.7 Set test vehicle hood open and remain open for test. 4.3.8 Set test vehicle drivers door windows down 15 cm from full upward, set remaining windows full up. 4.3.9
21、Light bank should be raised, solar simulation lamps off as noted in 4.3.1. 4.3.10 Battery charger shall be connected to test vehicle to maintain battery voltage between 11.5 V and 12.5 V during testing. Measure battery voltage during all test points. 4.3.11 When test vehicle is equipped with mechani
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW157542013ACSERVICETABLEDATACOLLECTIONPROCEDUREISSUE2ENGLISHPDF

链接地址:http://www.mydoc123.com/p-757704.html