GMW GMW14782-2011 Air-Side Characteristics of the A C and Heater Module Issue 2 English《空调和加热器模块的空气侧特性 第2次出版(英文版本)》.pdf
《GMW GMW14782-2011 Air-Side Characteristics of the A C and Heater Module Issue 2 English《空调和加热器模块的空气侧特性 第2次出版(英文版本)》.pdf》由会员分享,可在线阅读,更多相关《GMW GMW14782-2011 Air-Side Characteristics of the A C and Heater Module Issue 2 English《空调和加热器模块的空气侧特性 第2次出版(英文版本)》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 WORLDWIDE ENGINEERING STANDARDS Test Procedure GMW14782 Air-Side Characteristics of the A/C and Heater Module Copyright 2011 General Motors Company All Rights Reserved December 2011 Originating Department: North American Engineering Standards Page 1 of 5 1 Scope Note: Nothing in this standard super
2、cedes applicable laws and regulations. Note: In the event of conflict between the English and domestic language, the English language shall take precedence. 1.1 Purpose. All test sequences shall be used to evaluate the air conditioning (A/C) and heater module itself, and shall, therefore, be perform
3、ed outside the vehicle. 1.1.1 Module Characteristic Curves. The air flow shall be determined as a function of the air-side resistance of the module for each of the six air settings: Bi-level (heater and ventilation), cold; Ventilation, cold; Heater cold; Heater warm; Defrost, warm; and Defog (heater
4、 and defrost), warm. The characteristic curves thus obtained are necessary on the one hand for evaluating the air-side capacity of the module; on the other hand, they set the preconditions for evaluating the flow quality of the air ducts in the vehicle. 1.1.2 Air Flow of “Bare Modules“ at a Specifie
5、d Air Resistance. The air capacity of the module as a function of the terminal voltage shall be examined for all the air settings of paragraph 1.1.1. To simulate as closely as possible the situation in the vehicle, resistance shall be applied upstream or downstream of the module, depending on the ai
6、r ducts being tested. See the appropriate Vehicle Technical Specification (VTS), Subsystem Technical Specification (SSTS), drawing, or equivalent. 1.2 Foreword. Not applicable. 1.3 Applicability. All A/C and heater modules. 2 References Note: Only the latest approved standards are applicable unless
7、otherwise specified. 2.1 External Standards/Specifications. None 2.2 GM Standards/Specifications. GMW3070 2.3 Additional References. Subsystem Technical Specification (SSTS) Vehicle Technical Specification (VTS) 3 Resources 3.1 Facilities. See details of test assembly and procedure for the specific
8、system at the test location. 3.2 Equipment. See details of test assembly and procedure for the specific system at the test location. 3.3 Test Vehicle/Test Piece. A/C or heater module. Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduct
9、ion or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW14782 Copyright 2011 General Motors Company All Rights Reserved December 2011 Page 2 of 5 3.4 Test Time. Not applicable. 3.5 Test Required Information. Not applicable. 3.6 Personnel/Skills. Not applicable.
10、 4 Procedure 4.1 Preparation. 4.1.1 Test Assembly. The test assembly must allow the air-side resistance outside the module to be varied. This can be achieved on the delivery or suction side of the blower, e.g., by means of a slider. 4.1.1.1 The air-side resistance of the module shall not be influenc
11、ed by the test assembly, i.e.: The free space in front of the blower intake must permit air to be sucked in “from infinity“, i.e., there shall be areas in which the air speed is practically zero. The air must be able to flow unhindered out of the module vents (“into infinity“). The air ducts shall n
12、ot be modified in any way by add-on parts (e.g., blower speed recorder). 4.1.1.2 The moment of inertia and the balance of the impeller may only be slightly changed by the blower speed recorder. 4.1.1.3 The blower voltage shall be measured directly at the motor terminals. 4.1.1.4 The module shall be
13、mounted in vehicle installation position. 4.1.1.5 The recirculating air flap shall be hermetically sealed. 4.1.1.6 The condensation drain shall be half closed. 4.1.1.7 The glove box cooler shall be closed. 4.1.1.8 In the event of unwanted air leakage (see paragraph 4.2.1), the module vents in questi
14、on shall be sealed. 4.1.2 With the blowers switched off, all instruments shall be calibrated to zero (“0“). During this process, all pressure gauges to be used in the test shall be compared. 4.1.3 For further information, see details of test assembly and procedure for the specific system. 4.2 Condit
15、ions. 4.2.1 Environmental Conditions. During the development phase of a module, it must be ensured that closed flaps do not leak. For further information, see details of test assembly and procedure for specific system. 4.2.2 Test Conditions. Deviations from the requirements of this standard shall ha
16、ve been agreed upon. Such requirements shall be specified on component drawings, test certificates, reports, etc. 4.3 Instructions. 4.3.1 The ambient temperature, relative humidity, and ambient pressure shall be recorded for each test sequence. Furthermore, the stability of these variables shall be
17、monitored during the test. 4.3.2 If modules with desired air leakage are tested, one measurement shall be taken with and one without leakage (e.g., floor with and without defrost bleed). 4.3.3 Module Characteristic Curves. At a fixed blower voltage of UG = 12 V (measurements at other voltages are pe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW147822011AIRSIDECHARACTERISTICSOFTHEACANDHEATERMODULEISSUE2ENGLISH 调和 加热器 模块 空气 特性 出版 英文 版本 PDF

链接地址:http://www.mydoc123.com/p-757572.html