1、 WORLDWIDE ENGINEERING STANDARDS Test Procedure GMW14712 Insertion/Extraction - Weatherstrips Copyright 2011 General Motors Company All Rights Reserved August 2011 Originating Department: North American Engineering Standards Page 1 of 13 1 Scope Note: Nothing in this standard supercedes applicable l
2、aws and regulations. Note: In the event of conflict between the English and domestic language, the English language shall take precedence. 1.1 Purpose. This standard describes the test to determine the insertion (push-on) and extraction (pull-off) forces of sealing profiles installed on metal flange
3、s. 1.2 Foreword. Not applicable. 1.3 Applicability. This standard is applicable to all flange mounted weatherstrips. 2 References Note: Only the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. ISO 188 ISO 7500-1 ISO 9513 2.2 GM Standards/Sp
4、ecifications. None 3 Resources 3.1 Facilities. Not applicable. 3.2 Equipment. 3.2.1 Test Machine. The force measuring device of the test machine shall correspond to ISO 7500-1 Class 1; the deflection measuring device shall correspond to ISO 9513 Class 0.2. The test machine shall be such that the req
5、uired velocity can be maintained. 3.2.2 Test Fixtures. Test fixtures shall be capable of securely holding the sample to be tested. The sample shall be held securely within the fixture such that the base of the carrier and the test blade are perpendicular to one another. Test fixtures are shown in Fi
6、gures A1 through A8 in Appendix A. 3.2.3 Test Blades for Body Seals. Length of blade shall be 100 1 mm. Blades shall be production representative having the appropriate sheet metal thickness with production representative paint system. If no blade thickness is specified on the part drawing or math d
7、ata file, a 5.0 mm blade shall be used for insertion testing, and 2.0 mm blade shall be used for extraction testing. 3.2.4 Test Blades for Glass Run Channels (GRC) and Belt Seals. Length of blade shall be 100 1 mm. Blades shall be production representative, having the appropriate sheet metal thickne
8、ss with production representative paint system. Blades/fixtures must match program specific vehicle environment; blades/fixtures must match door outer panel, inner panel, and any reinforcements that interface with the weatherstrip. See Figures A6 through A8 for examples of blades/fixtures. Nominal f
9、lange thickness must be specified on the part drawing/math data file. Insertion shall be tested on maximum flange thickness; extraction shall be tested on minimum flange thickness. 3.3 Test Vehicle/Test Piece. Test samples shall consist of sections cut from production weatherstrips. 3.3.1 For initia
10、l sample approval and arbitration purposes, at least four test pieces cut from at least two components shall be tested. For routine quality control purposes, at least three test pieces, preferably from two components, shall be tested. Copyright General Motors Company Provided by IHS under license wi
11、th General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW14712 Copyright 2011 General Motors Company All Rights Reserved August 2011 Page 2 of 13 3.4 Test Time. Not applicable. 3.5 Test Required Information. Not
12、 applicable. 3.6 Personnel/Skills. Not applicable. 4 Procedure 4.1 Preparation. 4.1.1 Test Sample Preparation. Cut weatherstrips in appropriate lengths for the test fixture used (see Figures A1 through A8 in Appendix A). Remove the sponge bulb and any external lips from the carrier, if they affect m
13、ounting or testing. 4.2 Conditions. Unless otherwise specified, the tests shall be performed at 23 5 C. 4.2.1 Environmental Conditions. The minimum time period between vulcanization and testing of elastomers shall be 72 h. The test piece shall remain at a temperature of 23 5 C for at least 8 h befor
14、e testing and shall be free from strain during this period. 4.2.2 Test Conditions. Deviations from the requirements of this standard shall have been agreed upon. Such requirements shall be specified on component drawings, test certificates, reports, etc. 4.3 Instructions. See Table A1 for required t
15、esting by part classification. 4.3.1 Mount the appropriate blade into the crosshead of the test machine. Zero the force measuring device. 4.3.2 Mount the insertion-extraction fixture to the base. 4.3.3 Insertion Test (Push-on Force) for Traditional Flange. 4.3.3.1 Insert part manually into the fixtu
16、re. 4.3.3.2 Insertion with Stop of Test Machine at a Defined Force. Set the automatic force limitation adequate to the force measurement device. Insert the blade into the part with the speed of 50 5 mm/minute, unless otherwise specified on part drawing or math data file. Run the machine until the au
17、tomatic force limitation stops the test. Record a force-deflection diagram. 4.3.3.3 Insertion with Stop of Test Machine at a Defined Deflection. 4.3.3.3.1 Lower the blade into the carrier of the part. Stop the blade 0.25 to 0.50 mm from the bottom of the carrier or before entering the mastic. Zero t
18、he deflection measurement of the test machine. 4.3.3.3.2 Raise the blade until the blade clears the part and fixture. Note the distance traveled and re-zero test machine. 4.3.3.3.3 Set the test machine travel for distance noted in 4.3.3.3.2. Run the insertion at 50 5 mm/minute, unless otherwise spec
19、ified, recording the forces. 4.3.4 Insertion Test for Non-traditional Flanges (T-flange, Snap-on Flange, etc.) Insertion testing shall be performed in a manner that most represents the motion used to install the part. The procedure (as specified by the Design Release Engineer) used for evaluation sh
20、all be specified on the part drawing or math data file. 4.3.5 Extraction Test (Pull-off Force) for Traditional Flanges, Open Carrier and Closed Carrier (Service Part). See Figure A9 for example of closed carrier condition. 4.3.5.1 Insert the appropriate blade into the crosshead of the test machine.
21、Zero the force measuring device. Remove the blade from the crosshead. 4.3.5.2 Insert (lower) the blade into the weatherstrip carrier manually (slowly) until it touches the bottom. Attach the blade to the crosshead of the test machine. 4.3.5.3 Run the extraction at 50 5 mm/minute, unless otherwise sp
22、ecified, recording the forces. 4.3.6 Extraction Test (Pull-off Force) for Crimped on Flange (COF) Applications. Supplier must complete extraction test on crimped seal. This can be completed by supplier using a representative crimp tool or by sending weatherstrip sections to the crimp tool supplier.
23、4.3.6.1 Preparation of the Crimping of the Weatherstrips. 4.3.6.1.1 Sample Preparation. Seven test sheet metal pieces shall be mounted continuously in a rail at a distance of 20 to 25 mm from each other. The central five sheet metal pieces shall have the specified thickness. (The outer sheet metal p
24、ieces are alignment blades and are not used for the test. The thickness may deviate up to 50% from the test blades.) The extraction (pull-off) force from panels 2, 4 and 6 shall be determined; the other panels are removed for attaching the weatherstrip in the extraction test fixture. Copyright Gener
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW147122011INSERTIONEXTRACTIONWEATHERSTRIPSISSUE2ENGLISH 嵌入式 抽出 风雨 出版 英文 版本 PDF

链接地址:http://www.mydoc123.com/p-757545.html