GMKOREA EDS-T-7516-2006 TEST METHOD FOR THE MELT FLOW INDEX OF THERMOPLASTICS (VERSION 3).pdf
《GMKOREA EDS-T-7516-2006 TEST METHOD FOR THE MELT FLOW INDEX OF THERMOPLASTICS (VERSION 3).pdf》由会员分享,可在线阅读,更多相关《GMKOREA EDS-T-7516-2006 TEST METHOD FOR THE MELT FLOW INDEX OF THERMOPLASTICS (VERSION 3).pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards TEST METHOD FOR THE MELT FLOW INDEX OF THERMOPLASTICS EDS-T-7516 ISSUED DATE: 1994. 08. 31 REVISED DATE: 2006. 06. 19 VERSION: 3 EDS-T-7516TEST METHOD FOR THE MELT FLOW INDEX OF THERMOPLASTICS PAGE: 1/5 ISSUED DATE: 1
2、994. 08. 31 REVISED DATE: 2006. 06. 19 VERSION: 3 GM DAEWOO Auto & Technology 1. PURPOSE This standard is used to determine the flow behavior of thermoplastics and the specified load and at the specified temperature. 2. DEFINITION 2.1. Melt flow index (M.F.I): The flow behavior of thermoplastics det
3、ermined by extruding test samples through an orifice in a given time under the specified conditions (load, temperature, etc.) 3. TEST METHOD 3.1. Prepare test pieces of granule or powder type whose composition coincides with that of finished products. 3.2. In case of testing with finished products o
4、f specific shape, each side shall not exceed 5 mm. 3.3. In general, a test piece of 3 to 6g is suitable for one cycle test. 3.4. For initial sample approval and arbitration, at least three cycles of test shall be performed, and for routine quality control at least two cycles of test shall be done. 4
5、. CONDITIONING Conditioning shall be conducted according to the requirements specified on the drawing or material standard. Unless otherwise specified, test pieces shall be stored at a temperature of +232K and a relative humidity of (505)% for minimum 16 hours. 5. APPARATUS 5.1. Testing apparatus fo
6、r the determination of melt flow index (see Fig. 1) 5.2. Temperature regulator which can maintain a certain temperature within a tolerance of 0.5K. 5.3. Microbalance with scale dividing value 1a . 5.4. Stop watch 6. TEST METHOD 6.1. Prior to the test, heat the piston and cylinder at a given test tem
7、perature for at least 15 min. previously. (Unless test temperature is not specified in the drawing or material standard, refer to Table 1.) Keep the test temperature within a tolerance of 0.5K during the test. EDS-T-7516TEST METHOD FOR THE MELT FLOW INDEX OF THERMOPLASTICS PAGE: 2/5 ISSUED DATE: 199
8、4. 08. 31 REVISED DATE: 2006. 06. 19 VERSION: 3 GM DAEWOO Auto & Technology Table 1a. Test conditions by resins Resin Condition polyethylene 1, 3, 4, 5, 6, 7 Ethylene - acetate vinyl 1, 2, 3, 4 Polypropylene 4, 6, 14, 16, 17 Polyacetal 4, Cellulose esters 4 Polystyrene 6, 8, 13, 15 Acrylonitrilc-but
9、adiene-styrene 8, 11, 15 Acrylics 9, 10, 13, 14, 15, 17 Polyamides 4, 12, 14, 18, 19 Polycarbonate 20, 21 Table 1b. Temperature and load by test conditions Condition Test temperature () Test load (Kg) N Condition Test temperature () Test load (Kg) N 1 125 0.3253.19 12 230 0.3253.19 2 150 2.16(21.18
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST75162006TESTMETHODFORTHEMELTFLOWINDEXOFTHERMOPLASTICSVERSION3PDF

链接地址:http://www.mydoc123.com/p-757297.html