GMKOREA EDS-T-7505-2006 TEST METHOD FOR DETERMINING THE METLING RANGE OF PLASTIC MATERIALS (VERSION 3).pdf
《GMKOREA EDS-T-7505-2006 TEST METHOD FOR DETERMINING THE METLING RANGE OF PLASTIC MATERIALS (VERSION 3).pdf》由会员分享,可在线阅读,更多相关《GMKOREA EDS-T-7505-2006 TEST METHOD FOR DETERMINING THE METLING RANGE OF PLASTIC MATERIALS (VERSION 3).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards TEST METHOD FOR DETERMINING THE METLING RANGE OF PLASTIC MATERIALS EDS-T-7505 ISSUED DATE: 1993. 07. 13 REVISED DATE: 2006. 06. 19 VERSION: 3 EDS-T-7505TEST METHOD FOR DETERMINING THE METLING RANGE OF PLASTIC MATERIAL
2、S PAGE: 1/3 ISSUED DATE: 1993. 07. 13 REVISED DATE: 2006. 06. 19 VERSION: 3 GM DAEWOO Auto & Technology 1. PURPOSE The purpose of this standard is to determine the melting range of plastic films, molded parts and the coatings on leather cloths etc. 2. SCOPE This standard shall specify the method for
3、 determining the melting range of the plastic materials. The melting range is indicated by the “variance“ of melting point determinations carried out on several representative test pieces. 3. TEST PIECES 3.1. Size of test pieces: The test pieces of (702)mm(50.5)mmthickness shall be taken from variou
4、s areas of available material but no closer than 100mm to an edge. Test pieces shall, wherever possible, be taken along a warp thread and along a weft thread or in longitudinal and transverse directions. For test samples in the form of strips, or narrow mouldings of width less than 10mm, the test pi
5、eces shall be taken in the longitudinal direction only. 3.2. Number of test pieces 3.2.1. For initial sample approval and arbitration purposes : at least 3 3.2.2. For routine quality control : at least 3 3.3. Sample of components or materials released to this specification shall be tested for confor
6、mity with the requirements of this specification and approval by GMDAT TECHINICAL CENTER prior to commencement of delivery of bulk supplies. 4. CONDITIONING For initial sample approval and arbitration purposes, conditioning shall be carried out according to EDS-T-7507. 5. APPARATUS 5.1. Heating Appa
7、ratus A heating device, providing a differentially heated surface plate and temperature scale fitted with an adjustable pointer, capable of calibration, shall be used. A suitable apparatus is a Kofler heating device manufactured by Messer Reichert Vienna, and illustrated in Fig.1. This apparatus con
8、sists of a rectangular surface plate (1) which is electrically heated at one end, providing a thermal gradient along the longitudinal direction. Temperature is indicated on the scale (2) via a pointer (4) which is connected to a sliding guide block (3) through an adjustable slider (5). EDS-T-7505TES
9、T METHOD FOR DETERMINING THE METLING RANGE OF PLASTIC MATERIALS PAGE: 2/3 ISSUED DATE: 1993. 07. 13 REVISED DATE: 2006. 06. 19 VERSION: 3 GM DAEWOO Auto & Technology Figure 1. Heating apparatus 5.2. Calibration media A set of heat sensitive crayons, paints or powders dividing into the appropriate te
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST75052006TESTMETHODFORDETERMININGTHEMETLINGRANGEOFPLASTICMATERIALSVERSION3PDF

链接地址:http://www.mydoc123.com/p-757290.html