1、GM DAEWOO Auto Curtin Mathheson Scientific, or its equivalent 2.6. Furnace Re-circulating furnace capable of keeping temperature of 260280 2.7. Carbon analyzer Leco CS 244 or its equivalent (For improved accuracy, equipment using an infrared detector is recommended.) (Note 2) To avoid damage of the
2、instrument panel, a proper acid collecting device shall be provided inside the equipment. For information on each equipment, refer to the supplier of the equipment. 2.8. Vapor degreaser (for method B) Philips manufacturing co., DETROIT, MI T48E or its equivalent 3. TEST CONDITIONS Unless specified o
3、therwise, all test values described here shall be based on materials controlled to temperature of 232 and relative humidity of 505% for min. 24 hours before test. 4. TEST PROCEDURES 4.1. Method A - power washer method EDS-T-7176DETERMINATION OF THE QUANTITY OF CARBON CONTAMINATION ON COLD ROLLED STE
4、EL SURFACES PAGE: 2/3 ISSUED DATE: 1998. 03. 31 REVISED DATE: 2006. 06. 19 VERSION: 2 GM DAEWOO Auto & Technology 4.1.1. At annealing, 300mm wide coil can be taken from the coil portion which corresponds to the coil eye (with minimal quantity of inside wrap removed). Evaluate surface carbon by takin
5、g a test piece from the sample as shown in the figure below. The sample shall be free from any pollutants that may contain rust, adhesive, crayon, pelt pen marker or carbon. (Normal protective oil may be contained.) Sample Discard Sample Fig 1. Sampling portions (unit : mm) (Note 3) The test piece f
6、or carbon contamination measurement is taken from from either end of the coil width. 4.1.2. According to the following washing conditions, power-wash the 300300 mm sample using Parco. Cleaner 348 of Oxy Metal Industries Corporation. (1) Spray time : 58 62 sec (2) Concentration : 7 8 g/l (3) Temperat
7、ure : 60 70 (4) Pressure : 62 76 KPa (5) Distance from nozzle : 15 20 Cm 4.1.3. Rinse with water of 6070 for 2832 seconds. The sample shall not be handled with bare hands but with clean rubber gloves worn. 4.1.4. Prepare solution by mixing HCl (for reagent) and deionized water with volume ratio 50%.
8、 4.1.5. Using clean rubber gloves, take a sheet of filtering paper made by glass fiber. (934 AH class, 5.5Cm - Whatman, Inc. or its equivalent) 4.1.6. With clean rubber gloves worn, completely dip glass fiber filtering paper into 50% HCl solution and proceed as follows: (1) By applying uniform and p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST71762006DETERMINATIONOFTHEQUANTITYOFCARBONCONTAMINATIONONCOLDROLLEDSTEELSURFACESPDF

链接地址:http://www.mydoc123.com/p-757261.html