GMKOREA EDS-T-5442-2008 THE ELECTRIC COMPONENTS TEST FOR VOICE WARNING UNIT.pdf
《GMKOREA EDS-T-5442-2008 THE ELECTRIC COMPONENTS TEST FOR VOICE WARNING UNIT.pdf》由会员分享,可在线阅读,更多相关《GMKOREA EDS-T-5442-2008 THE ELECTRIC COMPONENTS TEST FOR VOICE WARNING UNIT.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards THE ELECTRIC COMPONENTS TEST FOR VOICE WARNING UNIT Do Not Use on New Programs. Being Replaced by GMW3172 EDS-T-5442 ISSUED DATE: 2001. 12. 18 REVISED DATE: 2008. 10. 21 VERSION: 3 (Superceded) THE ELECTRIC COMPONENTS
2、 TEST FOR VOICE WARNING UNIT EDS-T-5442PAGE: 1/8 ISSUED DATE: 2001. 12. 18 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology Note: This standard may be applied only for current project (incl. T255 Program). It is Superceded for all future projects and replaced by GMW3172. 1. PURPOSE
3、To evaluate component performance of Voice Warning Unit (hereafter called VWS) applied for GMDAT (hereafter called the Company) vehicles. 2. APPLICABLE EXTENT Applied for VWS component test mounted to passenger car. 3. DEFINITION 3.1. Voice Warning Unit Generating voice warring through Double Voice
4、Coil Speaker by detecting abnormal operation of vehicle system. 3.2. Double Voice Coil Speaker Available to perform audio input & voice warning by 1 speaker with double coil vibrating diaphragm in speaker. 4. TEST CONDITION 4.1. Standard Test Voltage The voltage indicated in drawing or test standard
5、 as test voltage for module performance & durability. 4.2. Standard test condition Carry out test at normal temp/humidity described in KS A006 (test site standard condition), if not specified. 4.3. DUT (device under test) quantity Based on 14 units at minimum. 5. TEST MEASURING UNIT & EQUIPMENT 5.1.
6、 General Governmental Authority of Calibration shall approve test-measuring unit and the period is to be valid. 5.2. Thermostat Available to maintain temp 40 to +90, the capacity shall be over 100 at minimum and permissible error shall be within +2/temp adjusting relative humidity up to 95% at each
7、temp as 5.3. Vibration test unit Available to perform test based on KS R 1034 (Vibration component vibration test method). THE ELECTRIC COMPONENTS TEST FOR VOICE WARNING UNIT EDS-T-5442PAGE: 2/8 ISSUED DATE: 2001. 12. 18 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology 5.4. Control
8、unit for durability test Auto circuit breaker able to apply or intercept power for unit operation during durability test and unit to record processing time & frequency by detecting error. 6. TEST 6.1. External test 6.1.1. Visual test (1) Visual inspection (2) Observe harmful scratch, crack and other
9、 defects to effect on performance by visual inspection. 6.1.2. Dimension test Indicated test tools in KS B 5203(vernier calipers) should be used, DUT is to be compiled to material quality according to deign spec and manufactures dimension is to be equal to drawing. 6.2. Performance 6.2.1. Basic func
10、tion test Operating parameter of basic performance in drawing is to be within tolerance of standard test voltage. 6.2.2. Operating Voltage (1) DUT should be normally operated at Operating Voltage, 9V16V & Operating temp, -30 +80 in supply voltage-9V to 16V, basic performance in 6.2.1 is to be satisf
11、ied. Only if necessary, operating temp items may be followed by drawing condition under agreement with test division. (2) Carry out measurement at 3-test voltage within operating voltage range, if there is no special rule indicated. 6.2.3. Leakage current (1) Carry out measurement at standard test v
12、oltage 12.6 0.1V of real load composition at battery power line. (2) Set ignition power line to OFF at this time. (3) Measured leakage current should not be exceeding of 5 , if there is no special rule indicated. 6.3. Electric Tolerance Test 6.3.1. Power voltage variation test (1) To check unit norm
13、al operation against electric shock caused by Power voltage alteration. (2) Compose DUT equal to design spec, apply the following test voltage of 10cycles to battery & ignition power terminal by voltage variation type respectively, then basic performance in 6.2.1 should be satisfied. * Test temp: St
14、andard test temp at normal temp/humidity * Total test cycle: 10 cycles * Test cycle THE ELECTRIC COMPONENTS TEST FOR VOICE WARNING UNIT EDS-T-5442PAGE: 3/8 ISSUED DATE: 2001. 12. 18 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology A TYPE (voltage variation wave form at engine starti
15、ng) B TYPE (Chattering generation wave form at Battery power supply) C Type (voltage variation wave form by IGN Key Switch) 6.3.2. Reverse/overload test (1) Carried out for protecting unit inner circuit against reverse/overload generated from vehicle at battery discharging. (2) Connect wiring equal
16、to car condition during test, operate unit by inserting inner protection circuit (fuse) to system with inner protection circuit. (3) Replace it immediately with inner protection circuit (fuse) of equivalent spec and connect it if the power is disconnected by inner protection circuit (fuse) operating
17、. (4) Compose DUT equal to design spec, apply the following test voltage cycle to battery & ignition power terminal by the following type, then basic function in 6.2.1para shall be satisfied. z Overload A Test voltage : 180.2V Test time: 60min Test temp: Standard test temp at normal temp/humidity T1
18、Volt 12(V) 0(V) SECT24SEC X 10Volt 8(V) 6(V) 1) Duty: 50% 2) Proximate wave form available Over 5Pulse1) T1: 1020mSEC 2) Duty: 50% 3) T2: Sufficient time for operation checkSECT1Volt 12(V) 0(V) SECT2Over 5Pulse4) T1:0. 53SEC 5) Duty: 50% 6) T2: Sufficient time for operation check Volt T2Over 5PulseT
19、HE ELECTRIC COMPONENTS TEST FOR VOICE WARNING UNIT EDS-T-5442PAGE: 4/8 ISSUED DATE: 2001. 12. 18 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology z Overload B Test voltage : 240.2V Test time: 1min Test temp: Standard test temp at normal temp/humidity z Reverse voltage Test voltage:
20、- 14 0.2V Test time: 1min Test temp: Standard test temp at normal temp/humidity 6.3.3. SHORT CIRCUIT No inner circuit damage and basic function in 6.2.1 shall be satisfied when all I/O signal terminal of unit is shorted to power terminal or ground for 1min at Standard test voltage. 6.3.4. ISOLATION
21、RESISTANCE TEST ISOLATION RESISTANCE shall be more than 500Mega Mohm (No exothermic, ignition due to leak current at case ground) when 500(V)-Alternating Current (AC) is applied between connector pin, connector and unit case. 6.4. Weather environmental test 6.4.1. High temp storage test (1) Compose
22、UDT equal to design spec. (2) Unit should be normally operated when basic function in 6.2.1 is measured after carrying out the following conditions and drying DUT for 2hrs at normal temp/humidity. z Test temp : +852 z Test time: 94 hrs z Test voltage : +14(V) Applied to battery & ignition power term
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST54422008THEELECTRICCOMPONENTSTESTFORVOICEWARNINGUNITPDF

链接地址:http://www.mydoc123.com/p-757160.html