GME GMI L-1B1201-8-2008 Air-Side Characteristics of the A C and Heater Module (English German This standard may be applied only for current projects incl Global Epsilon e (37##) Itpla.pdf
《GME GMI L-1B1201-8-2008 Air-Side Characteristics of the A C and Heater Module (English German This standard may be applied only for current projects incl Global Epsilon e (37##) Itpla.pdf》由会员分享,可在线阅读,更多相关《GME GMI L-1B1201-8-2008 Air-Side Characteristics of the A C and Heater Module (English German This standard may be applied only for current projects incl Global Epsilon e (37##) Itpla.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、LBSP GMI TP 1 11/95INTERNATIONALENGINEERINGSTANDARDSTest Procedure GMI L-1B1201-8Air-Side Characteristics of the A/C and Heater ModuleLuftseitige Kenndaten A/C und HeizungsmoduleJanuary 2008 Page 1 of 9Note: This standard may be applied only for current projects incl. Global Epsilon (37#). Itis Supe
2、rceded for all future projects and replaced by GMW14782.Hinweis: Diese Spezifikation darf nur noch fr laufende Projekte einschlielich GlobalEpsilon (37#) angewendet werden und ist fr alle zuknftigen Projekte ungltig undersetzt durch GMW14782.GM INTERNATIONAL ENGINEERING STANDARD GMI L-1B1201-8Januar
3、y 2008 Page 2 of 9LBSP GMI 2 11/95RevisionsDate ParagraphReplacement for GME L-1B1201-803.96 TDCE releasenderungenDatum AbschnittErsatz fr GME L-1B1201-803.96 TEZ Freigabe01.08 set to Superseded 01.08 Status auf “Superseded” gesetztGM INTERNATIONAL ENGINEERING STANDARD GMI L-1B1201-8January 2008 Pag
4、e 3 of 9LBSP GMI 2 11/951 Introduction 1 Einleitung1.1 PurposeAll test sequences shall be used to evaluate theA/C and heater module itself and shall therefore beperformed outside the vehicle.1.1 ZweckAlle durchzufhrenden Mereihen dienen der Beur-teilung von A/C und Heizungsmodules selbst undfinden d
5、aher auerhalb des Fahrzeuges statt.1.1.1 Module Characteristic CurvesThe air flow shall be determined as a function ofthe air-side resistance lined-up or subsequentlyadded of the module for each of the six air settings-Bi-level (heater and ventilation), cold; ventilation,cold; heater cold; heater wa
6、rm; defrost, warm anddefog (heater and defrost), warm.The characteristic curves thus obtained are neces-sary on the one hand for evaluating the air-side ca-pacity of the module; on the other hand, they setthe preconditions for evaluating the flow quality ofthe air ducts in the vehicle.1.1.1 Modulken
7、nlinienFr jede der sechs Luftfhrungseinstellungen MaxLuft (Furaum und Belftung) kalt, Belftung kalt,Furaum kalt, Furaum warm, Entfrostung warmund Defog (Furaum u. Entfrostung) warm wird derLuftdurchsatz in Abhngigkeit des dem Modul vor-oder nachgeschalteten luftseitigen Widerstandesbestimmt.Die hier
8、durch gewonnenen Kennlinien sind einer-seits notwendig zur Beurteilung des luftseitigen Lei-stungsvermgens des Moduls und dienen anderer-seits als Voraussetzung zur Beurteilung der str-mungstechnischen Qualitt der Luftfhrungen imFahrzeug.1.1.2 Air Flow of “Bare Modules“ at a SpecifiedAir ResistanceT
9、he air capacity of the module as a function of theterminal voltage shall be examined for all the airsettings of paragraph 1.1.1.In order to simulate as closely as possible the situ-ation in the vehicle, resistance shall be applied up-stream or downstream of the module, depending onthe air ducts bein
10、g tested (see VTS, SSTS, drawingor equivalent).1.1.2 Luftdurchsatz “Bare Module“ bei spezifi-zierten LuftwiderstndenDie Luftleistung des Moduls in Abhngigkeit derKlemmenspannung soll fr alle in Abschnitt 1.1.1erwhnten Luftfhrungseinstellungen berprft wer-den.Um der Situation im Fahrzeug mglichst nah
11、e zukommen, wird dem Modul ein luftfhrungsabhngi-ger Widerstand (gem VTS, SSTS, Zeichnungo.) vor- oder nachgeschaltet.1.2 ForewordN.a.1.2 VorwortN.a.1.3 ApplicabilityFor all A/C and heater modules.1.3 AnwendbarkeitFr alle A/C und Heizungsmodule.1.4 DefinitionsN.a.1.4 DefinitionenN.a.GM INTERNATIONAL
12、 ENGINEERING STANDARD GMI L-1B1201-8January 2008 Page 4 of 9LBSP GMI 2 11/951.5 References 1.5 Referenzen1.5.1 Order of PrecedenceIn the event of a conflict between the text of thetest procedure and the documents cited herein, thetext of the test procedure takes precedence.Nothing in the test proced
13、ure, however, supersedesapplicable laws and regulations unless a specificexemption has been obtained.Remark: In the event of a conflict between theEnglish and the domestic language, the Englishlanguage shall take precedence.1.5.1 Rangfolge der DokumenteIm Falle eines Widerspruchs vom Text dieses Prf
14、-verfahrens und den Dokumenten, die in dem Prf-verfahren enthalten sind, hat der Text des Prfver-fahrens Vorrang. Falls keine Ausnahmen vereinbartwurden, darf das Pfverfahren keine anzuwenden-den Gesetze und Regelungen auer Kraft setzen.Hinweis: Im Falle von Unstimmigkeiten zwischendem englischen un
15、d dem landessprachlichen Text,ist der englische Text ausschlaggebend.1.5.2 Government DocumentsN.a.1.5.2 Staatliche DokumenteN.a.1.5.3 General Motors Documents 1.5.3 General Motors Dokumente1.5.3.1 GMIODetails of Test Assembly and Procedure for thespecific System of the Test FacilitiesGMI L-1B1201-1
16、4Air-side Characteristics of the Vehicle1.5.3.1 GMIOAnlagenspezifische Anweisungen zu Versuchsauf-bau und -durchfhrung der PrfeinrichtungenGMI L-1B1201-14Luftseitige Kenndaten Fahrzeug.1.5.3.2 NAON.a.1.5.3.2 NAON.a.1.5.4 Industry DocumentsN.a.1.5.4 Industrie DokumenteN.a.1.5.5 Supplier DocumentsN.a.
17、1.5.5 Lieferanten DokumenteN.a.1.5.6 Other DocumentsN.a.1.5.6 Andere DokumenteN.a.2 Resources 2 Gerte und Einrichtungen2.1 FacilitiesSee details of test assembly and procedure for thespecific system at the test location.2.1 EinrichtungSiehe anlagenspezifische Anweisungen zu Ver-suchsaufbau und -durc
18、hfhrung am Testort.2.2 EquipmentSee details of test assembly and procedure for thespecific system at the test location.2.2 AusrstungSiehe anlagenspezifische Anweisungen zu Ver-suchsaufbau und -durchfhrung am Testort.GM INTERNATIONAL ENGINEERING STANDARD GMI L-1B1201-8January 2008 Page 5 of 9LBSP GMI
19、 2 11/952.3 Test Vehicle/Test PieceA/C or heater module.2.3 Versuchsfahrzeug/ProbekrperA/C oder Heizungsmodul.3 Procedure 3 Durchfhrung3.1 Preparation 3.1 Vorbereitung3.1.1 Test AssemblyThe test assembly must allow the air-sideresistance outside the module to be varied. Thiscan be achieved on the de
20、livery or suction side ofthe blower, e.g. by means of a slider.The air-side resistance of the module shall not beinfluenced by the test assembly, i.e.:- The free space in front of the blower intake mustpermit air to be sucked in “from infinity“, i.e. thereshall be areas in which the air speed is pra
21、cticallyzero.- The air must be able to flow unhindered out of themodule vents (“into infinity“).- The air ducts shall not be modified in any way byadd-on parts (e.g. blower speed recorder).The moment of inertia and the balance of theimpeller may only be slightly changed by the blowerspeed recorder.T
22、he blower voltage shall be measured directly atthe motor terminals.The module shall be mounted in vehicle installationposition.The recirculating air flap shall be hermeticallysealed.The condensation drain shall be half closed.The glove box cooler shall be closed.In the event of unwanted air leakage
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMEGMIL1B120182008AIRSIDECHARACTERISTICSOFTHEACANDHEATERMODULEENGLISHGERMANTHISSTANDARDMAYBEAPPLIEDONLYFORCURRENTPROJECTSINCLGLOBALEPSILONE37ITPLAPDF

链接地址:http://www.mydoc123.com/p-755452.html