《GME 8716-2007 Intrusion Protection of Tank Vent System (English Includes Appendix A This specification may be applied only for current projects incl Global Epsilon e (37##) It is Sd .pdf》由会员分享,可在线阅读,更多相关《GME 8716-2007 Intrusion Protection of Tank Vent System (English Includes Appendix A This specification may be applied only for current projects incl Global Epsilon e (37##) It is Sd .pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Test ProcedureRoad GME8716Intrusion Protection of Tank Vent SystemNote: This specification may be applied only for current projects incl. Global Epsilon (37#). It isSuperceded for all future projects and replaced by GMW14510 and GMW14547.1 IntroductionNote: Nothinginthisstandardsupersedesapplicablel
2、aws and regulations.Note: In the event of a conflict between the Eng-lish and the domestic language, the English languageshall take precedence.1.1 Purpose. To evaluate Intrusion Protection,depending on the design to decide witch kind ofintrusion to perform:Water IntrusionDust IntrusionSnow Intrusion
3、1.2 Foreword. Not applicable.1.3 Applicability. For all passenger cars.1.4 Definitions.Intrusion: Water, dust, snowthatissuckedintothetank venting system2 ReferencesNote: Only the latest approved standards are appli-cable unless otherwise specified.2.1 External Standards/Specifications.SAE 9300182.2
4、 GM Group Standards/Specifications. None.2.3 Additional References. PT Guideline 203 Resources3.1 Facilities.3.1.1 Water Intrusion.3.1.1.1 Water through (25 m, up to 0.3 m deep).3.1.1.2 Wet road (total length 200 km).3.1.2 Dust Intrusion. Dust-covered track (totallength 200 km).3.1.3 Snow Intrusion.
5、 Snow-covered track (totallength 200 km).3.2 Equipment.3.2.1 Two vacuum pumps (the desired flow to bereached by adjusting the voltage to the pump).3.2.2 Air flow meter (0.60) l/min.3.2.3 Water trap.3.2.4 Two dust traps incl. air filter capable of filteringdown to 5 micron particles (like diesel fuel
6、 filter).3.2.5 Lead car.3.2.6 Weight scale up to 5000 g.3.2.7 Equipment to measure pressure in tank andlines.3.2.8 Camera (dust, snow).3.3 Test Vehicle / Test Piece. A production intentvehicle is recommended, to be set to curb mass andspecified heights.3.4 Test Time. Not applicable.3.5 Test Required
7、 Information. Not applicable.3.6 Personnel / Skills. Not applicable.4 Procedure4.1 Preparation.4.1.1 Flooded Road.4.1.1.1 Install water trap between atmosphere tankventilate and tank (diesel) or atmosphere tank venti-late and carbon canister or instead of carbon canister(gasoline).4.1.1.2 Install th
8、e vacuum pump after the water trap.4.1.1.3 Ensure that water can not enter tank ventintake, engine air intake and purge line (gasoline).4.1.1.4 Ensure carbon canister purge rate of 30 l/min(gasoline), or 2 l/min (Diesel). Copyright 2007 General Motors Corporation All Rights ReservedPublication Depar
9、tment: GME Specification CenterMay 2007 - Issue No. 2 Page 1 of 4PRD045 - VPRE ST 1 10/03GME8716 GM EUROPE ENGINEERING STANDARDS4.1.2 Water Spray.4.1.2.1 Install water trap between atmosphere tankventilate and tank (diesel) or atmosphere tank venti-late and carbon canister or instead of carbon canis
10、ter(gasoline).4.1.2.2 Install the vacuum pump after the water trap.4.1.2.3 Ensure that water can not enter tank ventintake, engine air intake and purge line.4.1.2.4 Ensure carbon canister purge rate of 30 l/min(gasoline), or 2 l/min (Diesel).4.1.2.5 Installreference tube(diameter=12mm)anda water tra
11、p in front of vehicle (see Figure 1).4.1.2.6 Install the vacuum pump after the referencewater trap.4.1.2.7 Ensure reference flow rate of 50 l/min.4.1.3 Dust Intrusion.4.1.3.1 Install dust trap incl. air filter between atmos-phere Tank ventilate andTank (Diesel) or atmosphereTank ventilate and carbon
12、 canister or instead of car-bon canister (gasoline).4.1.3.2 Install the vacuum pump after the dust trap.4.1.3.3 Install safe replacement tank vent and closepurge line (gasoline).4.1.3.4 Ensure carbon canister purge rate of 30 l/min(gasoline), or 2 l/min (Diesel).4.1.3.5 Install reference tube ( = 12
13、 mm) with dusttrap incl. air filter in front of vehicle (see Figure 1).4.1.3.6 Install the vacuum pump after the dust trap.4.1.3.7 Ensure reference flow rate of 50 l/min.4.1.3.8 Preconditioning both air filter (see Note).4.1.3.9 Afterthe preconditioningbothairfiltershallbeweighed.Note: Filters shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GME87162007INTRUSIONPROTECTIONOFTANKVENTSYSTEMENGLISHINCLUDESAPPENDIXATHISSPECIFICATIONMAYBEAPPLIEDONLYFORCURRENTPROJECTSINCLGLOBALEPSILONE37ITISSDPDF
链接地址:http://www.mydoc123.com/p-754985.html