GEIA EIA-591-1992 Assessment of Quality Levels in PPM Using Variables Test Data (Formerly TechAmerica EIA-591)《用变量试验数据评定PPM的质量等级》.pdf
《GEIA EIA-591-1992 Assessment of Quality Levels in PPM Using Variables Test Data (Formerly TechAmerica EIA-591)《用变量试验数据评定PPM的质量等级》.pdf》由会员分享,可在线阅读,更多相关《GEIA EIA-591-1992 Assessment of Quality Levels in PPM Using Variables Test Data (Formerly TechAmerica EIA-591)《用变量试验数据评定PPM的质量等级》.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、EIA STANDARD ANSI/EIA-591- 1992 Approved: November 12, 1992 Reaffied: February 11,2000 Reaffirmed: September 5, 2002 Assessment of Quality Levels in PPM Using Variables Test Data EIA-591 DECEMBER 1992 ELECTRONIC INDUSTRIES ALLIANCE GOVERNMENT ELECTRONICS AND INFORMATION TECHNOLOGY ASSOCIATION A SECT
2、OR OF Elsctrlinic Indu6tries Alliance Copyright Government Electronics McGraw-Hill, New York, 1983. David, H.A., Order Statistics; John Wiley (ii) the specification includes only a lower limit (Section (iii) the specification includes only an upper limit (Section 8.); 9.) As indicated in Section l.,
3、 these procedures are applied to variables data. In the following example, imagine that the data values represent measurements of electrical resistance in ohms on twenty resistors that are intended to have a specification nominal resistance of 1,000 ohms.* The sample data, in ohms, are as follows: 1
4、016 1047 1055 1015 1028 960 1009 1011 1018 978 1021 992 996 978 977 1047 1021 1019 1040 1004 Now, using any computer program that calculates correlation coefficient, make two vertical columns. The first column is the sample data above, put in ascending order and labeled Y. The values for column X ar
5、e found in Table 2. For this example, 20 data values are used, so column X is a copy of the values under “Sample Size 20“. * Note that the data values could just as well represent measurements of tensile strength in pascals, or length in millimeters, or capacitance in farads, or measurements of any
6、other variable in appropriate physical units. Copyright Government Electronics it falls between 4.1967 and 4.9961. Consequently, it is necessary to interpolate between these two values which represent fractions nonconforming (P) of .O01 and .0001, as read across the top of Table 3. The K values of T
7、able 3 and 4 are different from the Z values found in the Area Table, so to reduce the chance of error, Table 5 gives the Z values corresponding to the fractions nonconforming (P) used in Tables 3 and 4. For this example, a K value of 4.1967 corresponds to a P value of .001. From Table 5, this corre
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GEIAEIA5911992ASSESSMENTOFQUALITYLEVELSINPPMUSINGVARIABLESTESTDATAFORMERLYTECHAMERICAEIA591 变量 试验 数据
链接地址:http://www.mydoc123.com/p-754547.html