《FORD WSS-M22P7-A4-2014 CABLE PRIMARY LOW TENSION THIN WALL 150C TO BE USED WITH FORD WSS-M99P1111-A (Shown on FORD WSS-M22P7-A1).pdf》由会员分享,可在线阅读,更多相关《FORD WSS-M22P7-A4-2014 CABLE PRIMARY LOW TENSION THIN WALL 150C TO BE USED WITH FORD WSS-M99P1111-A (Shown on FORD WSS-M22P7-A1).pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATION Material Name Specification Number Date Action Changes/Revisions 2014 06 11 N Status No replacement named L. Sinclair, NA 1999 11 18 Revised Added A7 Comp. Revision R. J. Patel 1997 03 12 Activated R. J. Patel Page 1 of 15 CABLE, PRIMARY LOW TENSION, THIN WALL, 85
2、C WSS-M22P7-A1 CABLE, PRIMARY LOW TENSION, THIN WALL, 100C WSS-M22P7-A2 CABLE, PRIMARY LOW TENSION, THIN WALL, 125C WSS-M22P7-A3 CABLE, PRIMARY LOW TENSION, THIN WALL, 150C WSS-M22P7-A4 CABLE, PRIMARY LOW TENSION, THIN WALL, NI PLATED, 175C WSS-M22P7-A5 CABLE, PRIMARY LOW TENSION, THIN WALL, NI PLAT
3、ED, 200C WSS-M22P7-A6 CABLE, PRIMARY LOW TENSION, THIN WALL, NI PLATED, 225C WSS-M22P7-A7 CABLE, PRIMARY LOW TENSION, THIN WALL, NI PLATED, 250C WSS-M22P7-A8 NOT TO BE USED FOR NEW DESIGN 1. SCOPE The products defined by these specifications are low tension stranded and insulated cables. The cables
4、are similar to that described in ISO 6722. This specification includes different temperature ratings and different conductor types i.e. plain copper, tinned copper, nickel plated copper, copper clad steel and copper alloy. 2. APPLICATION These cable specifications were originally released for use at
5、 a nominal system voltage of 60 V rms or less in automotive electrical harnesses. 3. REQUIREMENTS 3.1 QUALITY SYSTEM REQUIREMENTS Material suppliers and part producers must conform to Quality System Requirements, QS-9000. Material specification requirements are to be used for initial qualification o
6、f materials. A Control Plan for ongoing production verification is required. This plan must be reviewed and approved by the relevant Ford Materials activity and/or Ford Supplier Technical Assistance (STA) prior to production parts submission. Appropriate statistical tools must be used to analyze pro
7、cess/product data and assure consistent processing of the materials. Part producers using this material in their products, must use Ford approved materials and must conform to a process control plan which has been approved by STA and/or the relevant Materials Activity. ENGINEERING MATERIAL SPECIFICA
8、TION WSS-M22P7-A1/A8 Page 2 of 15 3.2 INFRARED SPECTROPHOTOMETRY AND/OR THERMAL ANALYSIS Ford Motor Company, at its option, may conduct infrared and/or thermal analysis of material/parts supplied to this specification. The IR spectra and thermograms established for initial approval shall constitute
9、the reference standard and shall be kept on file at the designated material laboratory. All samples shall produce IR spectra and thermograms that correspond to the reference standard when tested under the same conditions. 3.3 CONDITIONING AND TEST CONDITIONS All test values indicated herein are base
10、d on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. 3.4 CABLE TEMPERATURE CLASS Depending upon the service conditions, the cables shall be made to
11、belong to one of the following eight classes of temperature: Class A1 - 40 to + 85C Class A2 - 40 to + 100C Class A3 - 40 to + 125C Class A4 - 40 to + 150C Class A5 - 40 to + 175C Class A6 - 40 to + 200C CLASS A7 - 40 to + 225C CLASS A8 - 40 to + 250C 3.5 CABLE OUTSIDE DIAMETER (ISO 6722) No single
12、value shall be outside the acceptable range of diameter as specified in Table 2. 3.6 CONDUCTOR (ASTM B 1, ASTM B 3, ASTM B 174, ASTM E 8, ISO 6722) 3.6.1 The individual strands of the conductor shall be soft or annealed copper per ASTM B 3 or tin-plated per ASTM B 33. Conductors of 0.35 mm2 size and
13、 smaller may use hard copper strands per ASTM B 1 or copper alloy strands. Annealed copper strand elongation (after bunching) and lay length shall conform to ASTM B 174. For high temperature applications, nickel plated copper shall be used. Minimum conductor strand count shall comply with Table 1 of
14、 this specification. Missing strands are not allowed. ENGINEERING MATERIAL SPECIFICATION WSS-M22P7-A1/A8 Page 3 of 15 3.6.2 The conductor diameter and electrical resistance shall be determined in accordance with ISO 6722. The Conductor Breaking Load Test shall be conducted in accordance with ASTM E
15、8. The values are specified in Table 1. 3.7 INSULATION (ISO 6722) 3.7.1 The color of the insulation shall be specified on engineering drawing. Base, stripe, and band marking color codes shall correspond to Table 4. Where striping is specified, either one or two stripes may be used. The individual st
16、ripe shall be a minimum of 7% wide, but not more than 15% of the circumference of the wire. The stripe shall be of the same class of material as the insulation. Where band marking is specified (for sizes 0.13 and 0.22 mm2), the band mark shall be 3 mm +/- 1 mm wide with a 25 mm +/- 5 mm pitch. If th
17、e insulation is dyed or painted, the Durability of Cable Marking Test must be performed on the finished product. 3.7.2 The material shall adhere closely to, but strip readily from the conductors, leaving them free of insulation and in suitable condition for applying terminals. The insulation thickne
18、ss shall be determined in accordance with ISO 6722. The insulation thickness shall comply with the values listed in Table 2. 3.8 CABLE QUALITY (TESTS) Insulation Resistance, Withstand Voltage, Thermal Overload, Winding test at Low Temperature (mandrel sizes per Table 5), Pressure at High Temperature
19、, and Heat Shrinkage Tests shall all be conducted in accordance with ISO 6722. Ozone Resistance Test shall be conducted in accordance with SAE J1128. Note: The following tests, 3.8.1, 3.8.2, 3.8.3, 3.8.4, 3.8.5 and 3.8.6 shall be tested in accordance with ISO 6722, but with exceptions to the require
20、ments as indicated. 3.8.1 Test for Insulation Faults (In Process Testing) The test voltage shall be: 0.13 - 0.5mm 3 KV 0.5mm2 5 KV 3.8.2 Short Term Heat Aging (ISO 6722) During Withstand Voltage Test, the voltage shall be applied immediately after immersion for 1 minute. Mandrel sizes are specified
21、in Table 5. ENGINEERING MATERIAL SPECIFICATION WSS-M22P7-A1/A8 Page 4 of 15 3.8.3 Long Term Heat Aging (For Initial Qualification Only) (ISO 6722) During Withstand Voltage Test, the voltage shall be applied immediately after immersion for 1 minute. The test temperatures are specified in the para 3.4
22、. Mandrel sizes are specified in Table 5. 3.8.4 Resistance to Flame Propagation (ISO 6722) Any combustion flame of insulating material shall extinguish within 70 seconds. 3.8.5 Fluid Resistance (ISO 6722) The fluids and the requirements are specified in Table 6. 3.8.6 Abrasion Resistance For sizes 6
23、.0mm either clause 3.8.6.1 or 3.8.6.2 Shall be used to fulfill the requirement. For sizes larger than 6.0mm sandpaper abrasion shall be specified. 3.8.6.1 Sandpaper (SAE J1128) The sandpaper abrasion resistance shall meet the minimum abrasion requirements in Table 3. 3.8.6.2 Scrape (ISO 6722) The sc
24、rape abrasion resistance shall meet the minimum abrasion requirements in Table 3. 3.8.7 Loss Of Mass (For Initial Qualification Only) (IEC 540, para 7 (7d) at 100 +/- 2 C) This test is required for wire size of 0.75 mm. The maximum loss of mass shall be 1 mg/cm2. Note: Loss of mass is required for c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSSM22P7A42014CABLEPRIMARYLOWTENSIONTHINWALL150CTOBEUSEDWITHFORDWSSM99P1111ASHOWNONFORDWSSM22P7A1PDF

链接地址:http://www.mydoc123.com/p-752605.html