FORD WSK-M1L125-A-2003 CABLE LOW TENSION VINYL INSULATED 105 DEGREES C THIN WALL TINNED TO BE USED WITH FORD WSS-M99P1111-A (Shown on WSK-M1L124-A)《最高工作温度105℃的镀锡薄壁乙烯基绝缘低压电缆 与标准F.pdf
《FORD WSK-M1L125-A-2003 CABLE LOW TENSION VINYL INSULATED 105 DEGREES C THIN WALL TINNED TO BE USED WITH FORD WSS-M99P1111-A (Shown on WSK-M1L124-A)《最高工作温度105℃的镀锡薄壁乙烯基绝缘低压电缆 与标准F.pdf》由会员分享,可在线阅读,更多相关《FORD WSK-M1L125-A-2003 CABLE LOW TENSION VINYL INSULATED 105 DEGREES C THIN WALL TINNED TO BE USED WITH FORD WSS-M99P1111-A (Shown on WSK-M1L124-A)《最高工作温度105℃的镀锡薄壁乙烯基绝缘低压电缆 与标准F.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2003 08 18 Revised Para 3.0 inserted; Para 3.1, 3.20, 3.21, 3.22, 4 deleted 1997 06 05 Revised Rev. Title, 3.8-11,Table 2c , Del.3.5;Upd. P.Selucky 1990 06 11 EE00I10063626003 Released MD/PL-10 U. /Schwarz Printed copies are uncontrolled Copyr
2、ight 2003, Ford Global Technologies, Inc. Page 1 of 9 CABLE, LOW TENSION, VINYL INSULATED, 105 C, WSK-M1L124-A THIN WALL, BARE CABLE, LOW TENSION, VINYL INSULATED, 90 C, WSK-M1L124-B STANDARD WALL, BARE CABLE, LOW TENSION, VINYL INSULATED, 105 C, WSK-M1L125-A THIN WALL, TINNED 1. SCOPE The materials
3、 defined by these specifications are low tension stranded cables, vinyl-insulated conductors. The cables are similar to ISO 6722 with a standard and thin wall insulation thickness. 2. APPLICATION These specifications were released originally for materials used in automotive electrical harnesses. Not
4、e: The assemblers of electrical wire harnesses shall use the bulk wire suppliers as shown in the Ford Motor Company Approved Source List. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Pr
5、oduction Materials (WSS-M99P1111-A). 3.2 CABLE 3.2.1 Specimen Length 1.2 m 3.2.2 The maximum outside diameter shall be determined by taking measurements at three points along the conductor length separated by at least 100 mm and recording the greatest overall diameter at each point. No single value
6、shall exceed the maximum overall diameter as specified in Tables 2a, 2b, and 2c. 3.3 CONDUCTOR 3.3.1 The conductor of all cable classes shall consist of bunched or stranded soft annealed copper wires. 3.3.2 Specimen Length 1.2 m 3.3.3 Three sections 10 mm long and separated by at least 400 mm shall
7、be cut from the specimen. Carefully remove the conductor without deformation of the insulation. ENGINEERING MATERIAL SPECIFICATIONWSK-M1L124-AWSK-M1L124-BWSK-M1L125-APrinted copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 2 of 9 3.3.4 The conductor diameter shall be deter
8、mined by measuring the inside diameter of the insulation taken at three points separated by at least 300 mm and recording the maximum inside diameter at each point. The measurements shall be made with an optical device accurate to at least 0.01 mm. No value shall exceed the maximum diameter of the c
9、onductor specified in Tables 2a, 2b, and 2c. 3.3.5 The conductor area may be determined by measuring individual strand diameters and calculating the sums of the individual strand areas. As an alternate method, conductor area may also be determined in accordance with FLTM BB 105-01 or by measuring th
10、e resistance in accordance with Tables 1 and 2c. 3.3.6 The strands shall be bunched and the maximum lay length shall be a maximum of 50 times the conductor diameter. Minimum number of wires shall comply with Tables 1 and 2c. Maximum variation between individual strand diameters must not exceed 10% p
11、er the following: Variation = max strand diameter - min strand diameter min strand diameter Missing strands are not allowed. 3.3.7 Elongation (ASTM B 3, prior to bunching) for d =/- 0.287 mm e 15% for d 0.287 mm e 20% where: d = individual strand diameter e = elongation of individual strand. 3.3.8 R
12、esistivity, max (ASTM B 193, at 20 C) Bare 1.7094 /cm Tinned 1.7593 /cm 3.4 INSULATION 3.4.1 The insulating material shall be polyvinyl chloride (PVC) material, homogeneous in character. The surface shall be smooth and even without cracks, knots, blisters, or other faults. ENGINEERING MATERIAL SPECI
13、FICATIONWSK-M1L124-AWSK-M1L124-BWSK-M1L125-APrinted copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 3 of 9 3.4.2 The color of the cables are per the Munsell Color Coding System and shall conform to Table 3. The following method shall be used to evaluate the color of the c
14、ables. Comparison must be made by a person with normal or corrected vision, under cool white fluorescent lighting. The surface being inspected and the tolerance set must be in the same plane. Cable samples must be placed flat, overlapping the color standard. Color tolerance Reference Sets are availa
15、ble from SAE, 400 Commonwealth Drive, Warrendale, PA 15096. As an alternative, the color of the cables can be per the DIN 47002 or IEC 304 and shall conform to Table 4. 3.4.3 The minimum insulation thickness shall be determined by taking measurements at three points separated by at least 100 mm and
16、recording the minimum insulation thickness at each point. The thickness shall be measured with an optical device accurate to at least 0.01 mm. No single value shall be lower than the minimum insulation thickness specified in Tables 2a, 2b, and 2c. 3.5 FAULT TESTING OF THE COMPLETE DELIVERY (in proce
17、ss testing) 3.5.1 When pulling the grounded dry cable through the test electrodes connected to the test voltage, there must be no punctures. The test electrodes may consist of a coil, a metal tube, metal ball chains or any other type of suitable electrode. 3.5.2 Test Voltage For wires =/- 0.5 mm23 k
18、Veff For wires 0.5 mm25 kVeff The power supply shall be a transformer delivering a sinusoidal voltage. The electrode length and the frequency of the AC voltage shall be chosen, considering the speed of cable running through the field of the electrode, so that each point of the cable shall be loaded
19、by at least nine voltage cycles. If in place of a sinusoidal voltage unidirectional pulses are applied, there must be 18 pulses on each point of the cable. 3.6 DURATION TEST VOLTAGE AND BREAKDOWN VOLTAGE (FLTM BB 101-12, The cable must not be punctured.) 3.6.1 Specimen Length 1.2 m 3.7 INSULATION RE
20、SISTIVITY (FLTM BB 101-13) 3.7.1 Specimen Length 5 m 3.7.2 Volume Resistivity, min 2 megaohm/m 3.8 INSULATION COMPRESSION TEST AT HIGH TEMPERATURE (FLTM BB 101-14) 3.8.1 Specimen Length 100 mm ENGINEERING MATERIAL SPECIFICATIONWSK-M1L124-AWSK-M1L124-BWSK-M1L125-APrinted copies are uncontrolled Copyr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSKM1L125A2003CABLELOWTENSIONVINYLINSULATED105DEGREESCTHINWALLTINNEDTOBEUSEDWITHFORDWSSM99P1111ASHOWNONWSKM1L124A

链接地址:http://www.mydoc123.com/p-750335.html