1、 FORD LABORATORY TEST METHOD EU-AU 050-02 Date Action Revisions 2000 08 30 Revised Editorial no technical change A. Cockman 2000 05 18 Edi torial no technical change A. Cockman 1993 01 04 Printed copies are uncontrolled Page 1 of 4 Copyright 2000, Ford Global Technologies, Inc. DETERMINATION OF CHLO
2、RINE CONTENT OF HIGH FREQUENCY ADHESIVES Application This procedure is used to determine the percentage of chlorine in PVC copolymer high frequency adhesives based on solid content. The material under test is volatilized by heating in an oxygen stream and totally burnt in an oxyhydrogen flame. The c
3、ombustion products are absorbed in a receiver. Apparatus and Reagents Required Combustion Apparatus For solid substances. Dr. Wickbold system (see sketch) Type 3. Source: Heraeus - Schott Quarzschmelze GmbH 6450 Hanau Germany pH Meter With glass electrode suitable for pH measurement. For the potenti
4、ometric titration a combined comparison electrode (Ag - AgCl) is required. (Reference solution KNO 3 saturated.) Magnetic Agitator and Stirring Rods Measuring Flasks 100 mL Beakers 250 mL Burettes 25 mL Fish Tail Burner Vacuum Pump Analytical Balance Quartz Combustion Boats FORD LABORATORY TEST METH
5、OD EU-AU 050-02 Page 2 of 4 Copyr ight 2000, Ford Global Technologies, Inc. Sodium Hydroxide Solution (NaOH) 1 Normal - for absorption. Sulphuric Acid (H2SO4) 20 % by Volume Prepared from 95 - 97 % sulphuric acid. Silver Nitrate Solution (AgNO3) 0.02 Normal. Potassium Pyrosulphate (K2S2O7) Condition
6、ing and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/ - 2 C a nd 50 +/ - 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. Weigh a specim
7、en of adhesive in a quartz boat to the nearest .1 mgf. The weight of the specimen used i s based on the chlorine content of the adhesive and must be chosen as follows: Approximately 25 mgf at 30 - 60 % Cl by weight Approximately 50 mgf at 10 - 30 % Cl by weight Minimum 100 mgf at 1 - 10 % Cl by weig
8、ht 0.5 - 3 g at below 1 % Cl by weight If inorganic substances are present in the adhesive, potassium pyrosulphate must be added to the sample to act as a flux. 2. The quartz boat is inserted in the gasifying chamber (A), the chamber locked with the ground glass joi nt (E) and the cock (F) opened. 3
9、. A 100 mL measuring flask is connected to the combustion apparatus. Open the cock between the combustion apparatus and the measuring flask. 4. Set under a vacuum of 150 - 300 mm mercury. 5. After opening of the cooling water valve, the burner (B) is ignited. The oxygen flow rate should be 1000 1/h
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMEUAU050022000DETERMINATIONOFCHLORINECONTENTOFHIGHFREQUENCYADHESIVES 高频 胶粘剂 含氯量 测定 PDF

链接地址:http://www.mydoc123.com/p-747767.html