FORD FLTM EU-AU 050-01-2001 DETERMINATION OF COATING WEIGHT OF HIGH FREQUENCY ADHESIVES《高频胶粘剂的涂层重量的测定》.pdf
《FORD FLTM EU-AU 050-01-2001 DETERMINATION OF COATING WEIGHT OF HIGH FREQUENCY ADHESIVES《高频胶粘剂的涂层重量的测定》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM EU-AU 050-01-2001 DETERMINATION OF COATING WEIGHT OF HIGH FREQUENCY ADHESIVES《高频胶粘剂的涂层重量的测定》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD EU-AU 050-01 Date Action Revisions 2001 01 31 Revised Editorial no technical change A. Cockman 1993 01 04 Printed copies are uncontrolled Page 1 of 4 Copyright 2001, Ford Global Technologies, Inc. DETERMINATION OF COATING WEIGHT OF HIGH FREQUENCY ADHESIVES Application Th
2、is procedure is used to determine the coating weight in gf/m2 of PVC copolymer based high frequency adhesives applied to cardboards or other material. The material under test is volatilised by heating in an oxygen stream and totally burnt in an oxyhydrogen flame. The combustion products are absorbed
3、 in a receiver. Apparatus and Reagents Required Combustion Apparatus For solid substances. Dr. Wickbold system (see sketch) Type 3. Source: Heraeus - Schott Quarzschmelze GmbH 6450 Hanau Germany pH Meter With glass electrode suitable for pH measurement. For the potentiometric titration a combined co
4、mparison electrode (Ag-AgCl) is required. (Reference solution KNO3 saturated.) Magnetic Agitator and Stirring Rods Measuring Flasks 100 mL Beakers 250 mL Burettes 25 mL Fish Tail Burner Vacuum Pump Analytical Balance FORD LABORATORY TEST METHOD EU-AU 050-01 Page 2 of 4 Copyright 2001, Ford Global Te
5、chnologies, Inc. Quartz Combustion Boats Sodium Hydroxide Solution (NaOH 1 Normal - for absorption. Sulphuric Acid (H2SO4) 20 % by Volume Prepared from 95 - 97 % sulphuric acid. Silver Nitrate Solution (AgNO3) 0.02 Normal. Potassium Pyrosulphate (K2S2O7) Conditioning and Test Conditions All test val
6、ues indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. Cut from the coated cardboard at least 5 specimens ea
7、ch 6 - 9 cm2 within +/- 1 mm2. Individually granulate each specimen and spread evenly in a quartz boat. If inorganic substances are present in the adhesive, potassium pyrosulphate must be added to the sample to act as a flux. 2. The quartz boat is inserted in the gasifying chamber (A), the chamber l
8、ocked with the ground glass joint (E) and the cock (F) opened. 3. A 100 mL measuring flask is connected to the combustion apparatus. Open the cock between the combustion apparatus and the measuring flask. 4. Set under a vacuum of 150 - 300 mm mercury. 5. After opening of the cooling water valve, the
9、 burner (B) is ignited. The oxygen flow rate should be 1000 1/h and hydrogen flow rate should be 400 1/h. The length of the oxyhydrogen flame is to be adjusted to approximately 10 cm. 6. The burner (B) is inserted into the ground glass joint and the absorption solution (NaOH) valve opened. The drop
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMEUAU050012001DETERMINATIONOFCOATINGWEIGHTOFHIGHFREQUENCYADHESIVES 高频 胶粘剂 涂层 重量 测定 PDF

链接地址:http://www.mydoc123.com/p-747766.html