FORD FLTM EU-AP 050-02-2001 CHEMICAL-PHYSICAL ANALYSIS OF VULCANISED RUBBER COMPOUNDS《经硫化处理的橡胶混合物的化学-物理分析》.pdf
《FORD FLTM EU-AP 050-02-2001 CHEMICAL-PHYSICAL ANALYSIS OF VULCANISED RUBBER COMPOUNDS《经硫化处理的橡胶混合物的化学-物理分析》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM EU-AP 050-02-2001 CHEMICAL-PHYSICAL ANALYSIS OF VULCANISED RUBBER COMPOUNDS《经硫化处理的橡胶混合物的化学-物理分析》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD EU-AP 050-02 Date Action Revisions 2001 01 31 Revised Editorial no technical change A. Cockman 2000 04 19 Editorial no technical change A. Cockman 1993 10 19 Printed copies are uncontrolled Page 1 of 4 Copyright 2001, Ford Global Technologies, Inc. CHEMICAL-PHYSICAL ANAL
2、YSIS OF VULCANISED RUBBER COMPOUNDS Application This test method is applicable for the testing of vulcanized compounds for all rubber parts (test slabs and finished parts), and is used for the determination of: A. Acetone extract-quantitatively (gravimetric). B. Infrared spectrogram of the acetone e
3、xtract for reference and comparison with subsequent deliveries. C. Ash content-quantitatively (gravimetric). D. Elastomer content quantitatively. E. Infrared spectrogram of the elastomer compound pyrolysate. Apparatus and Chemicals Required Infrared Spectrophotometer Double beam type - capable of re
4、cording over a wavelength range of approx 2 - 15 microns and accessories. Sodium Chloride Plates or equivalent Suitable for the infrared spectrophotometer. Laboratory Distillation (simple type) Electric Heating Mangle For 250 mL flasks - 3 stage adjustable. Soxhlet Extraction Apparatus With 70 mL ex
5、tractor and 250 mL narrow neck flask. Evaporation Dish 100 mL Analytical Balance Accuracy +/- 1 mg FORD LABORATORY TEST METHOD EU-AP 050-02 Page 2 of 4 Copyright 2001, Ford Global Technologies, Inc. Muffle Furnace Capable of maintaining a temperature of 800 +/- 25 C. Retort Stand With 2 round clamps
6、, 3 flask clamps together with a mounting ring to support the soxhlet apparatus and the heating mantle. Acetone (A.R.) Porcelain Crucible with Cover Desiccator with Silica Gel Combustion Apparatus Grote-Krekeler type with electrical heating. Adjustable resistance, temperature recorder and porcelain
7、boat. Inert Gas e.g., nitrogen, helium or argon, pure and free from oxygen and moisture. Test Tubes 130 x 14 mm Fiolax No. 28 or equivalent. Bunsen Burner Cotton Wool Test Tube Clamps n-Propylalcohol (A.R.) Laboratory Convection Oven Capable of maintaining a temperature of 80 +/- 2 C. Glass Beaker 5
8、0 mL Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY
9、TEST METHOD EU-AP 050-02 Page 3 of 4 Copyright 2001, Ford Global Technologies, Inc. Procedure 1. Cut from the material under test (test slab or finished part) small pieces of max 5 mm side. Weigh approx. 6-8 g of the material to the nearest mg (E1). Before cutting, all parts must first be rinsed wit
10、h ethanol and then briefly with petroleum ether (38-70 C) in order to remove surface materials such as glycerin, grease etc. Allow 5 minutes minimum drying time before weighing. 2. Then extract with acetone for 24 h or as otherwise specified. 3. After extraction, dry in the oven at 80 +/- 2 C for 8
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便