FORD FLTM BZ 151-01-2015 DETERMINATION OF EMISSIONS OF ORGANIC AND CARBONYL COMPOUNDS FROM MATERIALS BY MICRO-CHAMBER METHOD.pdf
《FORD FLTM BZ 151-01-2015 DETERMINATION OF EMISSIONS OF ORGANIC AND CARBONYL COMPOUNDS FROM MATERIALS BY MICRO-CHAMBER METHOD.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BZ 151-01-2015 DETERMINATION OF EMISSIONS OF ORGANIC AND CARBONYL COMPOUNDS FROM MATERIALS BY MICRO-CHAMBER METHOD.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BZ 151-01 Date Action Revisions Rev. 0 2015 10 01 Released D. Stark, NA Controlled document at www.MATS Copyright 2015, Ford Global Technologies, LLC Page 1 of 3 DETERMINATION OF EMISSIONS OF ORGANIC AND CARBONYL COMPOUNDS FROM MATERIALS BY MICRO-CHAMBER METHOD Applicati
2、on This procedure is used as a material-level screening method for the emissions of selected volatile organic compounds (VOCs) from C6 C16 and carbonyl compounds. Apparatus and Materials Required Micro-Chamber Markes M-CTE250TM (or equivalent) with inside diameter chamber cells equal to or larger th
3、an 64 mm (2.5 inches) or area larger than 0.0032 m2 (4.9 inches2) Gas Chromatograph / Mass Spectrometer (GC/MS) Agilent GC6890N(7890A)/MS5975B (or equivalent) with Chemstation data acquisition / analysis software (version D.03.00.611 or equivalent) Thermal Desorption (TD) Markes TD-100 Thermal Desor
4、ption Unit (TDU) Gerstel Twister (or equivalent) with CIS4 cold injection system and 012440-004-00 straight liner, no packing; including MAESTRO software (or equivalent) Thermal Desorption System Autosampler (TDSA) Gerstel TDSA2 with CIS4 cold injection system and 013238-005-00 straight liner packed
5、 with 10 mg Tenax TA; including MASter software (or equivalent). Note: This system should not be used for the testing of leather. TD Tubes Gerstel TDU Tubes - Gerstel Carbopack B / Carbopack X (part number: 015954-005-00) Note: Preferred for the testing of leather. Gerstel TDSA Tubes - Tenax TA or C
6、arbotrap 300. Note: Carbotrap 300 should not be used for the testing of leather. Markes TD Tubes - Tenax TA High Performance Liquid Chromatography (HPLC) Agilent 1100 or 1260 (or equivalent) with Chemstation data acquisition / data analysis software (or equivalent) 2,4-dinitrophenylhydrazine (DNPH)
7、Cartridge Waters Corporation: Sep-Pak silica cartridge, catalogue number WAT037500, (or equivalent) Bonna-Agela Technologies: Cleanert IC-DNPH (or equivalent) FORD LABORATORY TEST METHOD BZ 151-01 Copyright 2015, Ford Global Technologies, LLC Page 2 of 3 Wire Stand Fabricated from McMaster-Carr #932
8、2T4: Easy-To-Form Type 304 stainless steel wire cloth; 2”x2” mesh size; 0.047” wire diameter; 0.453” opening size. Dimensions of wire stand to be approximately 50 mm (1.97 inches) in diameter and 10 mm (0.39 inches) in height. See Figure 1. Gas Flowmeter Agilent AMD 2000 (or equivalent) Test Materia
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBZ151012015DETERMINATIONOFEMISSIONSOFORGANICANDCARBONYLCOMPOUNDSFROMMATERIALSBYMICROCHAMBERMETHODPDF

链接地址:http://www.mydoc123.com/p-747706.html