《FORD FLTM BV 103-1-2000 DETERMINATION OF PRESSURE FLOWMETER VISCOSITY OF SEALERS ADHESIVES AND DEADENER MATERIALS (Replaces FLTM BV 003-01 FLTM EU-BV 003-01 FLTM EU-BV 050-01).pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BV 103-1-2000 DETERMINATION OF PRESSURE FLOWMETER VISCOSITY OF SEALERS ADHESIVES AND DEADENER MATERIALS (Replaces FLTM BV 003-01 FLTM EU-BV 003-01 FLTM EU-BV 050-01).pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BV 103-01 Date Action Revisions 2000 12 08 Revised Editorial no technical change A. Cockman 1993 12 17 Printed copies are uncontrolled Page 1 of 6 Copyright 2000, Ford Global Technologies, Inc. DETERMINATION OF PRESSURE FLOWMETER VISCOSITY OF SEALERS, ADHESIVES AND DEADE
2、NER MATERIALS Application This method is used to measure the viscosity of adhesives, sealers, and sound deadeners of paste-like consistency. This method is applicable to both the solvent-release and the solvent-free materials, in either the as-received or aged condition. Apparatus Required Flow-Rate
3、 Measuring Apparatus Refer to Figures 1, 2, and 3. Compressed Air Supply 600 kN/m2, with a delivery tube diameter of 6.25 mm. Manometer Accuracy of +/- 5 kN/m2. Balance Accuracy of +/- 0.05 g. Stop Watch Or equivalent timing device for measuring seconds. Thermostat Laboratory Forced-Air Circulation
4、Oven Capable of maintaining temperatures up to 60 +/- 2 C. Procedure Preparation Of Test Material A. Viscosity as received: 1. Condition the sample for 24 h at 23 +/- 2 C. FORD LABORATORY TEST METHOD BV 103-01 Page 2 of 6 Copyright 2000, Ford Global Technologies, Inc. 2. Determine the viscosity at 2
5、3 +/- 2 C. B. Viscosity after aging: 1. Fill the container (a 1 L can with a press-on lid) three-quarters full with the material under test, ensuring that the lid is closed tightly. 2. Condition the material for 336 h at the following aging temperatures, unless otherwise specified, and an additional
6、 24 h at 23 +/- 2 C: aging temperature - solvent-release material 50 +/- 2 C aging temperature - solvent-free material 30 +/- 2 C 3. Determine the viscosity at 23 +/- 2 C. Test Procedure (Refer to Figures 1, 2, and 3) 1. Unless otherwise specified, place a 2 mm diameter nozzle “C“ into the cylinder.
7、 Fill the cylinder “B“ with the material under test and place the plunger “D“ in position. 2. Screw the 2 cylinders together and connect the water jacket “H“ to the thermostat. 3. Heat the material to the required temperature (should be reached within 30 minutes). 4. Open the control valve “F“ and s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBV10312000DETERMINATIONOFPRESSUREFLOWMETERVISCOSITYOFSEALERSADHESIVESANDDEADENERMATERIALSREPLACESFLTMBV00301FLTMEUBV00301FLTMEUBV05001PDF

链接地址:http://www.mydoc123.com/p-747592.html