FORD FLTM BV 101-1-2000 COLD ADHESION TEST FOR DEADENERS AND UNDERCOATING (Replaces FLTM BV 001-01).pdf
《FORD FLTM BV 101-1-2000 COLD ADHESION TEST FOR DEADENERS AND UNDERCOATING (Replaces FLTM BV 001-01).pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BV 101-1-2000 COLD ADHESION TEST FOR DEADENERS AND UNDERCOATING (Replaces FLTM BV 001-01).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BV 101-01 Date Action Revisions 2000 12 08 Revised Editorial no technical change A. Cockman 1992 11 02 Printed copies are uncontrolled Page 1 of 4 Copyright 2000, Ford Global Technologies, Inc. COLD ADHESION TEST FOR DEADENERS AND UNDERCOATING Application These tests are
2、 used to determine the adhesion properties of automobile deadeners and undercoating materials when subjected to impact at a low temperature. Apparatus Required Slamming Fixture The slamming fixture, shown in the attached sketch, is used to deliver a uniform impact to the test panels. Contact area of
3、 the panel during the slamming test is 13.00 mm on each side and bottom edge of the panel. The top of the panel enclosed by the jaws does not contact the fixture when slammed. Cold Box The cold box shall be large enough to accommodate the fixture during the slamming test. The box should be capable o
4、f maintaining temperatures of - 23 to - 40 C. Drying Oven Convection type, capable of maintaining a temperature of 38 +/- 2 C to 204 +/- 3 C. Balance Laboratory beam or equivalent - accurate to 0.1 gram. Spray Booth Binks or equivalent. Airless Spray Equipment for Deadener or Undercoating Pyles Indu
5、stries Pump, Model 2600-485 - 20:1 ration - 0.052 reverse-a-clean tip or equivalent airless equipment suitable for spraying the deadener or undercoating under evaluation. Spray Equipment for Primer Binks No. 62 Air Cap 66SH, Tip 66SS - air pressure 3.471 - 5.694 kg/cm2 or equivalent. Steel Test Pane
6、ls The panels shall be 300 x 300 x 1 mm flat cold rolled low carbon steel body panels. A 6 mm hole is drilled in the center of one end for suspending the panel. Panels are considered flat when a 8 mm feeler gage cannot be inserted between the metal and a flat glass surface with either surface up and
7、 measured at 13 mm from each corner. FORD LABORATORY TEST METHOD BV 101-01 Page 2 of 4 Copyright 2000, Ford Global Technologies, Inc. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative h
8、umidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. Clean and phosphate coat the steel panels in accordance with Performance Specification ESB-M3P1-A. 1A. Where specification requires, CRLC steel shall be coated with mill oil.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。