FORD FLTM BQ 117-1-2000 SAND BOX CORROSION TEST.pdf
《FORD FLTM BQ 117-1-2000 SAND BOX CORROSION TEST.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BQ 117-1-2000 SAND BOX CORROSION TEST.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BQ 117-01 Date Action Revisions 2000 11 10 Revised Editorial no technical change A. Cockman 1999 01 22 Printed copies are uncontrolled Page 1 of 3 Copyright 2000, Ford Global T echnologies, Inc. SAND BOX CORROSION TEST Application This test procedure is used to evaluate
2、the relative corrosion performance of plated and/or painted parts. It was originally developed to test tubing, but can be used for any metallic part. Tubing tested under this method may undergo an additional (optional) pressure leak test. This is an accelerated test that is intended to simulate the
3、corrosive conditions chassis components are exposed to during normal vehicle use. Apparatus Required Test Box A box, with cover , made of high heat (120 C) resistant material such as polycarbonate. Dimensions are at the discretion of the testing facility, but depth of box must be a minimum of 3 time
4、s the diameter of the largest parts that will be tested. Drain holes of 10 mm dia meter are to be drilled in the bottom of the box every 100 - 140 cm. Samples As appropriate for the desired material under evaluation, and/or as specified by the engineering document. Actual components (tubing, clamps,
5、 tube/end fitting combinations) or sections of components should be used whenever possible. Nylon Net 1 layer of nylon mesh (landscape fabric), 3 mesh/cm (20 mesh/in), to be spread over the bottom of the test box. Laboratory Oven Air circulating oven capable of maintaining a temperature of 120 C and
6、 large enough to hold the test box. Materials Required Sand* Only sand of quartz - type is to be used. Designation Medium Grain Size, mm Max-min Grain Size, mm Sand A 0.65 0 - 1.6 Sand B 0.30 0 - 0.6 Sand C 0.18 0 - 0.35 Kaolin 0.01 FORD LABORATORY TEST METHOD BQ 117-01 Page 2 of 3 Copyright 2000, F
7、ord Global Technologies, Inc. * The following supplier may be contacted to purchase pre - mixed sand required in procedure step 2: Downriver Testing Services PO Box 1027 Rockwood, MI 48173 Contact: Wayne Miller, (734) - 75 3 - 4410 ext. 12 Sodium Chloride Reagent grade Sample Preparation Tube sample
8、s should have ends capped or masked to prevent corrosion of internal surface. Conditioning and Test Conditions All test values indicated herein are based on material conditio ned in a controlled atmosphere of 23 +/ - 2 C and 50 +/ - 5 % relative humidity for not less than 24 h prior to testing and t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBQ11712000SANDBOXCORROSIONTESTPDF